Preferred Language
Articles
/
joe-976
Asphaltene Precipitation Modeling of Sadi Formation in Halfaya Iraqi Oil Field
...Show More Authors

Asphaltene is a component class that may precipitate from petroleum as a highly viscous and sticky material that is likely to cause deposition problems in a reservoir, in production well, transportation, and in process plants. It is more important to locate the asphaltene precipitation conditions (precipitation pressure and temperature) before the occurring problem of asphaltene deposition to prevent it and eliminate the burden of high treatment costs of this problem if it happens. There are different models which are used in this flow assurance problem (asphaltene precipitation and deposition problem) and these models depend on experimental testing of asphaltene properties. In this study, the used model was equation of state (EOS) model and this model depends on PVT data and experimental data of asphaltene properties (AOP measurement) and its content (asphaltene weight percent). The report of PVT and flow assurance of the live oil from the well (HFx1) of the zone of case study (Sadi formation in Halfaya oil field) showed that there is a problem of asphaltene precipitation depending on asphaltene onset pressure (AOP) test from this report which showed high AOP greater than local reservoir pressure. Therefore this problem must be studied and the conditions of forming it determined. In the present work, the asphaltene precipitation of Halfaya oil field was modeled based on the equation of state (EOS) by using Soave-Redlich-Kwong (SRK) equation which gave the best matching with the experimental data. The main result of this study was that the reservoir conditions (pressure and temperature) were located in the asphaltene precipitation region which means that the asphaltene was precipitated from the oil and when the pressure of the reservoir decreases more with oil production or with time it will cause asphaltene deposition in the reservoir by plugging the pores and reducing the permeability of the formation.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Modeling of a Sulfonation Reactor in a Detergent Factory
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Economics And Administrative Sciences
Suggested Procedures According To COSO Integrated Framework To Evaluate The Internal Control System In Iraqi Oil Companies
...Show More Authors

The research amid to measure the extent of the Suggested procedures of the internal control in accordance with the updated COSO framework in improving the procedures for internal control work in Iraqi oil companies. As the research problem was represented in suggesting procedures for internal control according to the updated COSO framework and finding out the relationship of correlation and influence between the suggested procedures and the internal control procedures that are done in the Iraqi oil companies. The research followed the quantitative approach to handling and analysing data by designing a Questionnaire to represent the research tool for collecting data. The study population was represented in the Iraqi oil companies,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2009
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Phosphorus Removal from Water and Waste Water by Chemical Precipitation Using Alum and Calcium Chloride
...Show More Authors

Phosphorus is usually the limiting nutrient for eutrophication in inland receiving waters; therefore, phosphorus concentrations must be controlled. In the present study, a series of jar test was conducted to evaluate the optimum pH, dosage and performance parameters for coagulants alum and calcium chloride. Phosphorus removal by alum was found to be highly pH dependent with an optimum pH of 5.7-6. At this pH an alum dosage of 80 mg/l removed 83 % of the total phosphorus. Better removal was achieved when the solution was buffered at pH = 6. Phosphorus removal was not affected by varying the slow mixing period; this is due to the fact that the reaction is relatively fast.
The dosage of calcium chloride and pH of solution play an importa

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 22 2018
Journal Name
Journal Of Economics And Administrative Sciences
Performance Appraisal of Human Resource Management and Its Effect on Achieving the Organizational Success -A Field Search at the Ministry of Oil-
...Show More Authors

The present study addressed "Performance Appraisal of Human Resource Management and Its Effect on Achieving the Organizational Success", for the topics of performance appraisal of human resource management and the organizational success gained an increasing interest being relatively important and modern topics which had a great effect on the future of organizations.

The study aimed at revealing the pattern of appraising the performance of human resource management for the study sample, and whether it was qualified to lead the ministry towards the organizational success, for this purpose two main hypotheses were formulated: 1) there is a positive significant correlation between both variables: performanc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Chemical Engineering And Processing - Process Intensification
Optimization of a combined electrocoagulation-electro-oxidation process for the treatment of Al-Basra Majnoon Oil field wastewater: Adopting a new strategy
...Show More Authors

The performance of a synergistic combination of electrocoagulation (EC) and electro-oxidation (EO) for oilfield wastewater treatment has been studied. The effect of operative variables such as current density, pH, and electrolyte concentration on the reduction of chemical oxygen demand (COD) was studied and optimized based on Response Surface Methodology (RSM). The results showed that the current density had the highest impact on the COD removal with a contribution of 64.07% while pH, NaCl addition and other interactions affects account for only 34.67%. The optimized operating parameters were a current density of 26.77 mA/cm2 and a pH of 7.6 with no addition of NaCl which results in a COD removal efficiency of 93.43% and a specific energy c

... Show More
View Publication Preview PDF
Scopus (44)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Chemical Engineering And Processing - Process Intensification
Optimization of a combined electrocoagulation-electro-oxidation process for the treatment of Al-Basra Majnoon Oil field wastewater: Adopting a new strategy
...Show More Authors

View Publication
Scopus (44)
Crossref (36)
Scopus Clarivate Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Sustainable Studies
Description of the word formation system in contemporary Russian
...Show More Authors

This paper deals with the description of the system of formation and derivation of words in the Russian language. In this work, we will present recent trends in the study of the Russian language that deal with vocabulary formation. The lexical system of the Russian language is associated with a common (or opposite) meaning; similar (or opposite) in stylistic characteristics; united by a common type of word formation; related to a common descent and belonging to a vocabulary of much or little use, etc. The results of the most prominent linguists and specialists who dealt with this topic will be presented, in addition to presenting their different views on word formation. The words of the Russian language consist of mor vimat that participate

... Show More
Publication Date
Sun Dec 30 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimating of Pore Pressure Gradient in Lower Fars Formation
...Show More Authors

In petroleum industry, the early knowledge of “pore pressure gradient” is the basis in well design and the extraction of these information is more direct when the pore pressure gradient is equal to normal gradient; however, this matter will be more complex if it deviate from that limit which is called “abnormal pore pressure”, if this variable does not put in consideration, then many drilling problems will occur might lead to entire hole loss. To estimate the pore pressure gradient there are several methods, in this study; Eaton method’s is selected to extract the underground pressure program using drilling data (normalized rate of penetration) and logs data (sonic and density log). The results shows that an abnormal high press

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Bulletin Of The Iraq Natural History Museum (p-issn: 1017-8678 , E-issn: 2311-9799)
MICROFCIES OF TEL HAJAR FORMATION IN SOUTH-WEST IRAQ
...Show More Authors

The Tel Hajar formation in the studied area has been divided into five microfacics units:

1) Fine hiogenic dolomite facies.

2) Sandy rich dolomite facies.

3) Dolomite diagenetic facies.

4) Recrystal1ized wackestone in microfacies.

5) Mudsione facies.

Microfacics reflect shallow marine water with open Circulation in the lower part of the formation and the environment of the upper is enclosed between upper tide and tide. The most important diagenesis was recrystallization and spary calcite deposit inside fossils chambers and pores.

View Publication Preview PDF
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Comparative Permeability Estimation Method and Identification of Rock Types using Cluster Analysis from Well Logs and Core Analysis Data in Tertiary Carbonate Reservoir-Khabaz Oil Field
...Show More Authors

Characterization of the heterogonous reservoir is complex representation and evaluation of petrophysical properties and application of the relationships between porosity-permeability within the framework of hydraulic flow units is used to estimate permeability in un-cored wells. Techniques of flow unit or hydraulic flow unit (HFU) divided the reservoir into zones laterally and vertically which can be managed and control fluid flow within flow unit and considerably is entirely different with other flow units through reservoir. Each flow unit can be distinguished by applying the relationships of flow zone indicator (FZI) method. Supporting the relationship between porosity and permeability by using flow zone indictor is ca

... Show More
View Publication Preview PDF
Crossref (1)
Crossref