Performance Enhancement of an Air Cooled Air Conditioner with Evaporative Water Mist Pre-cooling
...Show More Authors

The present paper deals with experimental investigation of the performance of air cooled split air conditioner, with evaporative water mist pre cooling to increase the cooling capacity and reduce the consumption power under hot and dry climate. This investigation considers how the performance can be enhanced by using water mist to pre-cool ambient air entering the condensers by adiabatic cooling process which depends on the ambient air wet bulb temperature; as well the condensing temperature and condensing pressure will be decreased accordingly. So the cooling capacity would be increased and consumption power would be decreased, consequently the energy ratio, EER would be improved. The performance of air cooled air conditioner with water mist pre cooling;
ECAC was compared to the performance of air cooled air conditioner, ACAC which tested under the same ambient condition that is ranged from 25 oC to 52 oC. Test results show that ECAC operating at EER of 10.5 BTV/W. The ECAC had an EER of 47 % higher than that of ACAC under the same and most serve hot and dry condition of 52 oC and 10% relative humidity. 
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Environmental Assessment of Polycyclic Aromatic Hydrocarbon Concentrations in Air at Thermal South Power Station of Baghdad
...Show More Authors

Sixteen polycyclic aromatic hydrocarbons (PAHs) concentrations were measured in aerosol samples collected for the period from April 2012 to February 2013 at thermal south power station of Baghdad. Fourty one aerosol sample were extracted with (1:1) dichloromethane and methanol using soxhlet for seventeen hour. The extraction solution was analyzed applying GC/MS. The PAH concentrations outside thermal south power station were higher than those inside it, and higher in summer season than in winter. Naphthalene, pyrene, Anthracene, Indeno [1, 2, 3-cd] pyrene and Phenanthrene were the most abundant PAHs detected in all points at the site sampling. The total polycyclic aromatic hydrocarbon (TPAH) and total suspended particles (TSP) concentrat

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
THEORETICAL AND EXPERIMENTAL STUDY ON THERMAL PERFORMANCE OF CLOSED WET COOLING TOWER
...Show More Authors

Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Special Topics & Reviews In Porous Media: An International Journal
EXPERIMENTAL AND NUMERICAL INVESTIGATION OF A DOUBLE PASS SOLAR AIR HEATER PROVIDED WITH POROUS ABSORBER PLATE FOR DRYING APPLICATIONS
...Show More Authors

This investigation integrates experimental and numerical approaches to study a novel solar air heater aimed at achieving an efficient design for a solar collector suitable for drying applications under the meteorological conditions of Iraq. The importance of this investigation stems from the lack of optimal exploitation of solar energy reaching the solar collector, primarily attributable to elevated thermal losses despite numerous designs employed in such solar systems. Consequently, enhancing the thermal performance of solar collectors, particularly those employed in crop drying applications, stands as a crucial focal point for researchers within this domain. Two identical double-pass solar air heaters were designed and constructed for

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2024
Journal Name
Results In Engineering
Experimental and analytical study of the energy and exergy performance for different evaporative pads in hot and dry climate
...Show More Authors

In this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D

... Show More
View Publication
Scopus (15)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
'Influence of Draft Tube Diameter on Operation Behavior of Air Lift Loop Reactors
...Show More Authors

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Enhancement of Hoisting System Performance
...Show More Authors

In this paper it is required to enhance the performance of a mechanical system (here: a Hoisting System) where it is preferred to lift a different payloads with approximately the same speed of lifting and keeping at the same time the good performance, and this of course needs some intelligence of the system which will be responsible on measuring the present load and taking into account the speed and performance desired in order to achieve the requirements or the criteria. The process therefore is a Mechatronics System design which includes a measuring system, a control or automation technique, and an actuating system. The criteria built here in this research using a given Hoist system's characteristics and parameters and changing one of

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Effect of sintering time on Bi1.6Pb0.4Sr1.8Ba0.2Ca2Cu3O10+? compound quenched in air and liquid nitrogen
...Show More Authors

High temperature superconductor with nominal composition Bi1.6Pb0.4Sr1.8Ba0.2Ca2 Cu3O10+? was prepared by solid state reaction method. Two sets of samples have been prepared .The first one was quenched in air; the second set was quenched in liquid nitrogen. X-ray diffraction analyses showed an orthorhombic structure with two phases, high –Tc phase (2223) and low-Tc phase (2212) in addition to that impure phase was found. It has been observed that quenched in air samples display a sharp superconducting transition and a higher-Tc phase than that of the quenched in liquid nitrogen samples.

View Publication Preview PDF
Crossref
Publication Date
Mon May 28 2018
Journal Name
Iraqi Journal Of Science
Use Citrus aurantium plant as bio-indicator of air pollution in Baghdad city
...Show More Authors

The current study was conducted to demonstrate the effects of air pollution on different biochemical parameters inCitrus aurantium plant and calculation the Air Pollution Tolerance Index (APTI). Five sites were selected tocollect plant leaves, four of them within the city of Baghdad, namely Al-Jadriya, Al-Andlous, Al-Doura and closeto the private generators to represent the urban areas and Abu Ghraib site to represent the rural area. Seasonalsamples were collected for the period from October 2016 to June 2017. Eleven biochemical parameters totalchlorophyll, ascorbic acid, leaf extract pH, relative water content, total nitrogen, total protein content, total sugarcontent, proline, electrical conductivity, cadmium and lead. The results of Citr

... Show More
Scopus (2)
Scopus