Preferred Language
Articles
/
joe-884
Kinetic Study of the Recovery of Phosphorus from Wastewater by Calcium Hydroxide Solution
...Show More Authors

This research presents a study for precipitating phosphorus (as phosphate ion) from simulated wastewater (5ppm initial concentration of phosphorus) using calcium hydroxide Ca(OH)2 solution. The removal of phosphorus by Ca (OH)2 solution is expected to be very effective since the chemical reaction is of acid-base type but Ca(OH)2 forms complex compound with phosphate ions called. Hydroxyapatite Ca5 (PO4)3OH. hydroxyapatite is slightly soluble in water. This research was directed towards sustainable elements as phosphorus. Kinetics of the dissolution reaction of hydroxyapatite was investigated to find the best factors to recover phosphorus. The effect of concentration of Ca(OH)2 (180- 380 ppm) on phosphorus precipitation on the outputs like the residual phosphorus concentration in the simulated solution, the percentage removal of phosphorus and the weight of the precipitate was also studied. The residual phosphorus decreased with increasing Ca(OH)2 concentration while the percentage removal, as well as the weight of the precipitate, increased with increasing Ca(OH)2 concentration at constant temperature and mixing speed. The best Ca(OH)2 concentration was obtained depending on the lowest amount of the residual phosphorus concentration. The best value obtained was 230 ppm at a fixed mixing speed of 400 rpm and a temperature of 20°C.  The best value for Ca(OH)2 concentration under fixed stirring speed and temperature was applied on a real wastewater taken from the detergent factory. The percentage removal was 30. 69% due to the complexity of the real sample. Oxalic acid was chosen to dissolve hydroxyapatite because it is an organic acid, less hazardous than mineral acids and of less cost. Kinetics of the dissolution reaction of hydroxyapatite in (160 ppm) concentration oxalic acid under ambient conditions (20°C and 1 atm (and mild stirring (200 rpm) was studied using the differential method for determining the order of the reaction which was 0.4296 and the rate constant 0.0743 (L/mg)-0.5704. min-1. The reaction was considered as a rate-controlled reaction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2024
Journal Name
Medical Journal Of Babylon
Viral Load of HBV and HCV Correlation to Torque Teno Virus (TTV) Co-Infection in Iraqi Patients
...Show More Authors
Abstract<sec> <title>Background:

While hepatitis viruses A–E are established, emerging evidence points to additional, novel viral hepatitis agents. The torqueteno virus (TTV) has garnered interest due to its prevalence among patients with hepatitis, suggesting potential hepatotropism.

Aim:

This study was conducted to detect TTV antigens in individuals infected with chronic hepatitis B (HBV) and/or C (HCV) using molecular diagnostics and to explore any associations between TTV presence and demographic characteristics of the cohort.

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Mon May 27 2019
Journal Name
Al-khwarizmi Engineering Journal
Prediction of Process Parameters That Affecting on Surface Roughness in Multi-Point Forming Process Using ANOVA Algorithm
...Show More Authors

 

Multipoint forming process is an engineering concept which means that the working surface of the punch and die is produced as hemispherical ends of individual active elements (called pins), where each pin can be independently, vertically displaced using a geometrically reconfigurable die. Several different products can be made without changing tools saved precious production time. Also, the manufacturing of very expensive rigid dies is reduced, and a lot of expenses are saved. But the most important aspects of using such types of equipment are the flexibility of the tooling. This paper presents an experimental investigation of the effect of three main parameters which are blank holder, rubber thickness and forming speed th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 25 2019
Journal Name
Engineering And Technology Journal
Synthesis, Characterization and Antibacterial activities of Uracil and Uracil–Oxalate Complexes with Cr(III) and Fe(III)
...Show More Authors

New complexes of the some trivalent transition metal ions of the uracil such as [M(Ura)3Cl3] and mixed ligand metal complexes with uracil and oxalic acid [M(Ura)2(OA)(OH2)Cl].H2O type, where (Ura)=Uracil, (OA= Oxalic acid dihydrate, (M= Cr+3 and Fe+3) were synthesized and characterized by the elemental analysis, FT.IR, electronic spectra, mass spectra and magnetic susceptibility as well as the conductivity measurements. Six–coordinated metal complexes were suggested for the isolated complexes of Cr+3 and Fe+3 with molecular formulas dependent on the nature of uracil and oxalic acid present. The proposed molecular structure for all complexes with their ions is octahedral geometries. The antibacterial efficiency was tested of metal salts, l

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Evaluation of Serum Malondialdehyde, Glutathione and Lipid Profile Levels in Iraqi Females with Type 2 Diabetes Mellitus
...Show More Authors

This study is carried out on patients with type 2 diabetes mellitus to assess the lipid profile, malondialdehyde and glutathione. Our study is concerned with 51 (Iraqi Arab females) patients of type 2 diabetes mellitus compared with 31 control subjects unified in age, sex and ethnic background. Lipid profile is measured by using commercially available kits, while the serum MDA and glutathione levels are measured by means of sandwich ELISA test using commercially available kits. Serum MDA is significantly higher (P<0.001) while glutathione is significantly lower (P<0.001) in type 2 diabetic patients when compared to the control. The normal levels of MDA (3.82 ± 0.77n mol/ml) and GSH (2.23 ± 0.54 µg/ml) recorded for the non-diabetic female

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Sep 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
Impact of Glycated Haemoglobin on salivary glucose among type 1 diabetic mellitus patients aged 18-22 years
...Show More Authors

Background: Diabetes mellitus consists of a group of diseases characterized by abnormally high blood glucose levels. Glycated haemoglobin (HbA1c) is a form of haemoglobin used to identify the average concentration of plasma glucose over prolonged periods of time. It is formed in a non-enzymatic pathway by normal exposure of hemoglobin to high levels of plasma glucose, The main alterations observed in the saliva of Type 1 diabetic patients are hyposalivation and alteration in its composition, particularly those related to the levels of glucose. The aim of the present study was to assess the effect of Glycated haemoglobin level on the level of salivary glucose which may have an effect on oral health condition. Materials and methods

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (89)
Crossref (80)
Scopus Clarivate Crossref
Publication Date
Tue Nov 01 2016
Journal Name
Polimery
Synthesis and monomer reactivity ratios of acrylamide with 3-(trimethoxysilyl)propyl methacrylate and tris(methoxyethoxy)vinylsilane copolymers
...Show More Authors

View Publication
Scopus (11)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Molecular Docking, Synthesis, characterization and preliminary cytotoxic evaluation of new 1, 3,4-Thiadiazole derivatives as EGFR inhibitors
...Show More Authors

View Publication
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref