Preferred Language
Articles
/
joe-857
Using Ultrasonic Pulse Velocity Test to Assess the Effect of Water-Cement Ratio on the Compressive Strength of Concrete
...Show More Authors

This study aims to find the effect of water-cement ratio on the compressive strength of concrete by using ultrasonic pulse velocity test (UPVT). Over 230 standard cube specimens were used in this study, with dimensions of 150mm, and concrete cubes were cured in water at 20 °C. Also, the specimens used in the study were made of concrete with varied water-cement ratio contents from 0.48 to 0.59. The specimens were taken from Diyarbakir-Turkey concrete centers and tested at the structure and material science lab, civil engineering, faculty of engineering from Dicle University.  The UPV measurement and compressive strength tests were carried out at the concrete age of 28 days. Their UPV and compressive strength ranged between (3.89-4.66km/s) and (17.74-40.56MPa) respectively. The experimental results showed that although the UPV and the compressive strength of concrete are related, also, the UPV and compressive strength have a relation with the rate of the water-cement ratio of concrete.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 16 2025
Journal Name
Journal Of Physical Education
The Effect of Proprioceptive Neuromuscular Facilitation Exercises Combined with Superset Pyramid on Maximal Strength in Classic Physique Athletes’ Lower Extremities
...Show More Authors

View Publication
Publication Date
Thu Jan 16 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of waterlase laser and herbal alternative, green tea and Salvadora Persica (Siwak) extract on push-out bond strength
...Show More Authors

Background: The bond strength of root canal sealers to dentin was important for maintaining the integrity of the seal in root canal filling in both static and dynamic situations. In a static situation, it should eliminate any space that allowed the percolation of fluids between the filling and the wall while in a dynamic situation; it was needed to resist dislodgement of the filling during subsequent manipulation. Materials and Methods: Forty mandibular premolars were selected for this study. All canals were instrumented using ProTaper rotary instruments. Instrumentation was done with copious irrigation of 5.25% sodium hypochlorite. Roots were randomly divided into four groups according to the type of cleaning and method of root canal irrig

... Show More
View Publication Preview PDF
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Effect of Temperature on the Synthesis of Nano-Gamma Alumina Using Hydrothermal Method
...Show More Authors

Nano gamma alumina was prepared by double hydrolysis process using aluminum nitrate nano hydrate and sodium aluminate as an aluminum source, hydroxyle poly acid and CTAB (cetyltrimethylammonium bromide) as templates. Different crystallization temperatures (120, 140, 160, and 180) 0C and calcinations temperatures (500, 550, 600, and 650) 0C were applied. All the batches were prepared at PH equals to 9. XRD diffraction technique and infrared Fourier transform spectroscopy were used to investigate the phase formation and the optical properties of the nano gamma alumina. N2 adsorption-desorption (BET) was used to measure the surface area and pore volume of the prepared nano alumina, the particle size and the

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 28 2017
Journal Name
Journal Of Engineering
Effects of Magnetized Water on the Accumulated Depth of Infiltration
...Show More Authors

This study was carried out to investigate the effects of magnetized water on accumulated infiltration depth. A test rig was designed and constructed for this purpose was installed at the water tests laboratory of the Department of Water Resources Engineering at the University of  aghdad. The investigation was carried out by using two types of soil, different flow velocities throughout magnetizing device and different configuration of magnets over and under the water passage of the magnetizing device. The soils that were used in the experiments are clayey and sandy soils.  Six different flow velocities throughout magnetizing device ranged between 0.29 to 1.19 cm/s and ten configurations of arranging the magnets over and under th

... Show More
View Publication Preview PDF
Publication Date
Sat Oct 29 2022
Journal Name
Current Trends In Geotechnical Engineering And Construction
Optimal Bedding Selection with the Specific Soil Type According to the Thrust Forces Generated in the Water Distribution Networks Using the Restraining Joint System
...Show More Authors

A study has been performed to compare the beddings in which ductile iron pipes are buried. In water transmission systems, bends are usually used in the pipes. According to the prescribed layout, at these bends, unbalanced thrust forces are generated that must be confronted to prevent the separation of the bend from the pipe. The bed condition is a critical and important factor in providing the opposite force to the thrust forces in the restraint joint system. Due to the interaction between the native soil and the bedding layers in which the pipe is buried and the different characteristics between them. Also, the interaction with the pipe material makes it difficult to calculate the real forces opposite to the thrust forces and the way they

... Show More
View Publication
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Australian Journal Of Mathematical Analysis And Applications
Formulation of approximate mathematical model for incoming water to some dams on Tigris and Euphrates Rivers using spline function
...Show More Authors

n this paper, we formulate three mathematical models using spline functions, such as linear, quadratic and cubic functions to approximate the mathematical model for incoming water to some dams. We will implement this model on dams of both rivers; dams on the Tigris are Mosul and Amara while dams on the Euphrates are Hadetha and Al-Hindya.

View Publication
Scopus
Publication Date
Sat Mar 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Minimizing error in robot arm based on design optimization for high stiffness to weight ratio
...Show More Authors

In this work the effect of choosing tri-circular tube section had been addressed to minimize the end effector’s error, a comparison had been made between the tri-tube section and the traditional square cross section for a robot arm, the study shows that for the same weight of square section and tri-tube section the error may be reduced by about 33%.

A program had been built up by the use of MathCAD software to calculate the minimum weight of a square section robot arm that could with stand a given pay load and gives a minimum deflection. The second part of the program makes an optimization process for the dimension of the cross section and gives the dimensions of the tri-circular tube cross section that have the same weight of

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
study the effects of the polluted waste water on the environment
...Show More Authors

to study the discribrion and the pollution in the environment in the south of baghdad samples of waste water from industrail units using the mercury in its process also

View Publication Preview PDF
Publication Date
Wed Feb 02 2022
Journal Name
Iraqi Journal Of Science
The evaluation effect of TiO2 nano particles on different bacterial strains isolated from water purification stations in Baghdad
...Show More Authors

The antibacterial activities of some nanoparticles, makes them attractive as a new agents against pathogenic bacteria. In this research, the antimicrobial effects of Titanium dioxide-nano-particles against seven bacterial isolates (E.coli, Enterobacter aerogenes, Pseudomonas alcaligenes, Aeromonas veronii, Aeromonas hydrophila, Serratia marcescens and Staphylococcus aureus) being isolated from different Baghdad water purification stations investigated. The physiochemical characters, which influence the quality of the drinking water for the air and water, demonstrated.The characterization of nanoparticles investigated by using Scanning Electrone Microscope, FTIR, and UV-Visible Spectrophotometer. The activity of different concentration of

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 23 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ESTIMATION OF SOME CHEMICAL AND PHYSICAL PROPERTIES USING A WATER TREATMENT UNIT VORTISAND COMPARED TO THEIR CONCENTRATION IN WATER PRODUCED BY TRIDINTINAL DRINKING WATER PROJECTS IN BAGHDAD.: ESTIMATION OF SOME CHEMICAL AND PHYSICAL PROPERTIES USING A WATER TREATMENT UNIT VORTISAND COMPARED TO THEIR CONCENTRATION IN WATER PRODUCED BY TRIDINTINAL DRINKING WATER PROJECTS IN BAGHDAD.
...Show More Authors

This study was conducted to determine the ability of water treatment system (Vortisand) to reduce some chemical and physical properties for tigris river raw water, It consisted of turbidity, electrical conductivity, pH, total hardness, calcium Hardness as well as temperature in order to determine the unit`s efficiency for reducing their concentration as compared to those in the water produced by some classical potable water projects (Dora and Wathba) in Baghdad. Samples were collected during the cold months (December 2016 and January 2017) and during the hot months (May and June 2017). The results showed that this system has the ability to reduce some properties such as turbidity, the values were 215NTU in raw water and decreased to NTU

... Show More
View Publication Preview PDF