In this paper, an Anti-Disturbance Compensator is suggested for the stabilization of a 6-DoF quadrotor Unmanned Aerial vehicle (UAV) system, namely, the Improved Active Disturbance Rejection Control (IADRC). The proposed Control Scheme rejects the disturbances subjected to this system and eliminates the effect of the uncertainties that the quadrotor system exhibits. The complete nonlinear mathematical model of the 6-DoF quadrotor UAV system has been used to design the four ADRCs units for the attitude and altitude stabilization. Stability analysis has been demonstrated for the Linear Extended State Observer (LESO) of each IADRC unit and the overall closed-loop system using Hurwitz stability criterion. A minimization to a proposed multi-objective Output Performance Index (OPI) is achieved in the MATLAB environment to tune the IADRCs parameters using Genetic Algorithm (GA). The IADRC has been tested for the 6-DOF quadrotor under different tracking scenarios, including disturbance rejection and uncertainties elimination and compared with nonlinear and linear PID controllers. The simulations showed the excellent performance of the proposed compensator against the controllers used in the comparison.
The experiment was conducted in twodifferentsplaces, one of this experiment in the field was not under salt stress and the other experiment field was under salt stress.Those experiments were conducted in college of AgricultureDiyalaUniversity atautmyseason (2015 - 2016)to study the salt stress by usingseeds soaking with Hydrogen Peroxide and foliar application in different concentrations ofAbscisic acid.The experiment statistical design as RCBD was with three replicates.Soaking the seeds withHydrogen Peroxidetreatments 0 , 10 , 15 , 20 mmol.L-1. Three Abscisic acid levels0 , 15 , 30 mg.L1.α -Tocopherol, Catalase Enzyme, Membrane Stability Index,prolin
... Show MoreThis paper presents the dynamic responses of generators in a multi-machine power system. The fundamental swing equations for a multi-machine stability analysis are revisited. The swing equations are solved to investigate the influence of a three-phase fault on the network largest load bus. The Nigerian 330kV transmission network was used as a test case for the study. The time domain simulation approach was explored to determine if the system could withstand a 3-phase fault. The stability of the transmission network is estimated considering the dynamic behaviour of the system under various contingency conditions. This study identifies Egbin, Benin, Olorunsogo, Akangba, Sakete, Omotosho and Oshogbo as the key buses w
... Show MoreBased on the needs of the scientific community, researchers tended to find new iterative schemes or develop previous iterative schemes that would help researchers reach the fixed point with fewer steps and with stability, will be define in this paper the multi_implicit four-step iterative (MIFSI) which is development to four-step implicit fixed point iterative, to develop the aforementioned iterative scheme, we will use a finite set of projective functions ,nonexpansive function and finite set from a new functions called generalized quasi like contractive which is an amalgamation of quasi contractive function and contractive like function , by the last function and a set of sequential organized steps, we will be able to prove the existen
... Show MoreAbstract
Robust controller design requires a proper definition of uncertainty bounds. These uncertainty bounds are commonly selected randomly and conservatively for certain stability, without regard for controller performance. This issue becomes critically important for multivariable systems with high nonlinearities, as in Active Magnetic Bearings (AMB) System. Flexibility and advanced learning abilities of intelligent techniques make them appealing for uncertainty estimation. The aim of this paper is to describe the development of robust H2/H∞ controller for AMB based on intelligent estimation of uncertainty bounds using Adaptive Neuro Fuzzy Inference System (ANFIS). Simulatio
... Show MoreKurdistan power system is expanded along years ago. The electrical power is transmitted through long transmission lines. The main problem of transmission lines is active and reactive power losses. It is important to solve this issue, unless, the most of electrical energy will lost over transmission system. In this study, High Voltage Direct Current links/bipolar connection were connected in a power system to reduce the power losses. The 132kV, 50 Hz, 36 buses Kurdistan power system is used as a study case. The load flow analysis was implemented by using ETAP.16 program in which Newton-Raphson method for three cases. The results show that the losses are reduced after inserted HVDC links.
Abstract: This research aims to investigate and analyze the most pressing issues facing the Iraqi economy, namely economic stability and inclusive growth Consequently, the present study investigates the effect of inflation and unemployment, which are significant contributors to economic instability, on inclusive growth dimensions such as GDP, education, health, governance, poverty, income inequality, and environmental performance. From 1991 to 2021, secondary data were collected using World Bank Indicators (WDI) and Organization for Economic Cooperation and Development (OECD) databases. The researchers also employed the autoregressive distributed lag (ARDL) model to determine the relationship between variables. The study revealed that fluct
... Show MoreThe Pulse Coupled Oscillator (PCO) has attracted substantial attention and widely used in wireless sensor networks (WSNs), where it utilizes firefly synchronization to attract mating partners, similar to artificial occurrences that mimic natural phenomena. However, the PCO model might not be applicable for simultaneous transmission and data reception because of energy constraints. Thus, an energy-efficient pulse coupled oscillator (EEPCO) has been proposed, which employs the self-organizing method by combining biologically and non-biologically inspired network systems and has proven to reduce the transmission delay and energy consumption of sensor nodes. However, the EEPCO method has only been experimented in attack-free networks without
... Show MoreIn this study, depleted uranium concentrations were calculated in sediments Diyala River samples , where 14 samples of sediment along the Diyala River were collected , starting from the Rustumiya area and ending with the Tuwaitha area after its confluence with the River Tigris , using the solid - state nuclear track detectors technique (SSNTDs). We found that the highest concentration of depleted uranium was in the sample (A-13), and was taken from the Tuwaitha area with the specific activity of the amount (78.1 ± 8.5 Bq/kg ) and the lowest concentration of the depleted uranium was in the sample (A-7), and was taken from the Azwaip area with the
... Show MoreAbstract The strategic performance of the United States depends on dealing with the Middle East countries and its variants on several bases and motives that enabled them to achieve American hegemony and invest its interests at the expense of the region countries. Within this performance, the administration of the United State President Donald Trump presented the Strategic Document on December 18, 2017, which focused on the principle of "America First", to determine the direction of future US strategic performance in the formulation of means of cooperation and intersections or hostility in addition to interests and threats.The future vision of the Arab region and the Middle East as a whole, this strategy is based on the fact that
... Show MoreThis paper aims to improve the voltage profile using the Static Synchronous Compensator (STATCOM) in the power system in the Kurdistan Region for all weak buses. Power System Simulation studied it for Engineers (PSS\E) software version 33.0 to apply the Newton-Raphson (NR) method. All bus voltages were recorded and compared with the Kurdistan region grid index (0.95≤V ≤1.05), simulating the power system and finding the optimal size and suitable location of Static Synchronous Compensator (STATCOM)for bus voltage improvement at the weakest buses. It shows that Soran and New Koya substations are the best placement for adding STATCOM with the sizes 20 MVAR and 40 MVAR. After adding STATCOM with the sizes [20MVAR and 40MV
... Show More