Preferred Language
Articles
/
joe-823
Investigation of Optimum Heat Flux Profile Based on the Boiling Safety Factor
...Show More Authors

An experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water temperature at cooling channel inlet is kept constant at (25°C). Copper test section of (0.6 m) length (0.025m) inner diameter is used during the experiments. The electrical heater used for water heating is wrapped around the copper pipe covering (50 cm) of its length. Calibrated thermocouples are distributed along pipe surface at distances (0.1, 0.2, 0.3, 0.4 and 0.5 m) from pipe inlet to measure pipe surface temperature. The results shows that the heat source with heat flux profile of type (c) is the most reliable one from thermo-hydraulic safety point of view for both types of heat sources, as it ensures a maximum boiling safety factor (K) of (1.6, 1.7, 2) at water flow rates of (5, 7 and 9 lit/min) respectively based on maximum heat capacity of (2665 w), while the heat source with heat flux profile of type (d) which posses minimum boiling safety factors of (1, 1.2, 1.3) at water flow rates of (5, 7 and 9 lit/min) respectively based on same heat capacity value is the worst one from same point of view.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Comparison of protein — A with clumping factor, hemolysis and coagulase tests for identification of Staphylococci isolated from Nasal swabs of healthy carriers
...Show More Authors

Thirty nine (12.8%) isolates of Staphylococcus aureus were isolated from 304 healthy human (Nasal swabs). It was found that percentage of males that have S. aureus is more than female's percentage. These isolates (39) were tested with different tests. Twenty seven isolates (69.23 %) were positive for Staphylococcus protein —A (SPA) ,thirty seven ( 94.8 %) were positive for tube coagulase , thirty five ( 89.7 % ) were positive with clumping factor and thirty two ( 82.05 %) had 13 — hemolytic on blood agar. It was found that 100% of the isolates (39 isolates) were positive with one, two or three tests (tube coagulase, clumping factor and SPA).

View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Cost technique based on ABCII specifications and its effect in the Implementation of contracting contracts: Applied research in Al-Mansour general company for construction contracting
...Show More Authors

The problem of research was to identify after the use of cost technology based on specifications in the validity of determining and measuring the costs of the implementation of contracting, by applying to al-Mansour General Construction Contracting Company as an appropriate alternative to the traditional costing system currently adopted, which is characterized by many shortcomings and weaknesses Which has been reflected in the validity and integrity of the calculations. To solve this problem, the research was based on the premise that: (The application of cost technology based on specifications will result in calculating the cost of the product according to the specification required by the customer, to meet his wishes properly and witho

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)
...Show More Authors

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental paramete

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Aug 05 2018
Journal Name
Journal Of Entomology And Zoology Studies
Some biochemical traits in broiler chicken as affected by insulin-like growth factor-1 (IGF-1) gene polymorphisms
...Show More Authors

This study was conducted during the period 1/9/2014 – 1/2/2015 and aimed to identify the polymorphisms of IGF-1 gene in broiler chickens and their effects on some biochemical traits. A total of 300 one-day-old broiler chicks (Cobb500, n=150; Hubbard F-15, n=150) were evaluated in this study. Blood samples were individually collected from all birds for DNA extraction. PCR-RFLP method being used for determination the genotypes of IGF-1 gene which then correlated with biochemical traits studied. Cobb500 broilers with TT genotype had significantly (p˂0.05) higher serum triglycerides values than those of TC and CC genotypes. Low density lipoprotein (LDL) were significantly (p˂0.05) higher in Hubbard F-15 broilers with TT genotype than those

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 01 2018
Journal Name
J Of Baghdad College Of Dentistry
Serum Tumor Necrosis Factor Alpha and High Sensitive C-Reactiveprotein as Biomarkersin Periodontitis in Iraqi Patients with Osteoarthritis
...Show More Authors

Publication Date
Wed Oct 11 2023
Journal Name
Journal Of Educational And Psychological Researches
The Degree of Student Teachers Acquisition at Sultan Qaboos University in Skills of Teaching Arabic via A Virtual Micro-Teaching Lab Based on their Point of View
...Show More Authors

The study aims to investigate the degree of student teachers at Sultan Qaboos University acquired skills in teaching Arabic via a virtual micro-teaching lab, as well as to reveal the difficulties they faced and their development proposals. To do this, the researchers developed a questionnaire divided into four dimensions: planning, implementation, evaluation, and

ethical values for the teaching profession, in addition to two open-ended questions to identify difficulties and suggestions. It was administered to (30) student teachers. The results revealed that the average degree of student-teacher acquisition of skills was high in its four dimensions. It ranged between (39.2) to (82.2), while the overall average was (56.2).

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 26 2022
Journal Name
Nanomaterials
Improved Melting of Latent Heat Storage Using Fin Arrays with Non-Uniform Dimensions and Distinct Patterns
...Show More Authors

Employing phase-change materials (PCM) is considered a very efficient and cost-effective option for addressing the mismatch between the energy supply and the demand. The high storage density, little temperature degradation, and ease of material processing register the PCM as a key candidate for the thermal energy storage system. However, the sluggish response rates during their melting and solidification processes limit their applications and consequently require the inclusion of heat transfer enhancers. This research aims to investigate the potential enhancement of circular fins on intensifying the PCM thermal response in a vertical triple-tube casing. Fin arrays of non-uniform dimensions and distinct distribution patterns were des

... Show More
View Publication
Scopus (36)
Crossref (35)
Scopus Clarivate Crossref
Publication Date
Fri Mar 29 2024
Journal Name
Iraqi Journal Of Science
Determination of Timewise-Source Coefficient in Time-Fractional Reaction-Diffusion Equation from First Order Heat Moment
...Show More Authors

     This article aims to determine the time-dependent heat coefficient together with the temperature solution for a type of semi-linear time-fractional inverse source problem by applying a method based on the finite difference scheme and Tikhonov regularization. An unconditionally stable implicit finite difference scheme is used as a direct (forward) solver. While by the MATLAB routine lsqnonlin from the optimization toolbox, the inverse problem is reformulated as nonlinear least square minimization and solved efficiently. Since the problem is generally incorrect or ill-posed that means any error inclusion in the input data will produce a large error in the output data. Therefore, the Tikhonov regularization technique is applie

... Show More
Preview PDF
Scopus Crossref
Publication Date
Fri Nov 26 2021
Journal Name
Nanomaterials
Solidification Enhancement in a Multi-Tube Latent Heat Storage System for Efficient and Economical Production: Effect of Number, Position and Temperature of the Tubes
...Show More Authors

Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that

... Show More
View Publication
Scopus (12)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref