Preferred Language
Articles
/
joe-823
Investigation of Optimum Heat Flux Profile Based on the Boiling Safety Factor
...Show More Authors

An experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water temperature at cooling channel inlet is kept constant at (25°C). Copper test section of (0.6 m) length (0.025m) inner diameter is used during the experiments. The electrical heater used for water heating is wrapped around the copper pipe covering (50 cm) of its length. Calibrated thermocouples are distributed along pipe surface at distances (0.1, 0.2, 0.3, 0.4 and 0.5 m) from pipe inlet to measure pipe surface temperature. The results shows that the heat source with heat flux profile of type (c) is the most reliable one from thermo-hydraulic safety point of view for both types of heat sources, as it ensures a maximum boiling safety factor (K) of (1.6, 1.7, 2) at water flow rates of (5, 7 and 9 lit/min) respectively based on maximum heat capacity of (2665 w), while the heat source with heat flux profile of type (d) which posses minimum boiling safety factors of (1, 1.2, 1.3) at water flow rates of (5, 7 and 9 lit/min) respectively based on same heat capacity value is the worst one from same point of view.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
Biochemical & Cellular Archives
The impact of follicular fluid growth differentiation factor 8 levels on IVF /ICSI outcomes
...Show More Authors

Clinical index is needed to predict the outcome of pregnancy after in vitro fertilization/intracytoplasmic sperm injection-embryo transfer (IVF/ICSI-ET) for infertile patients. Growth differentiation factor-8 (GDF-8), also known as myostatin, is one of transforming growth factor-â superfamily localized in antral follicles in normal and PCOS ovaries but its function in female reproductive system is still unknown. Aim of the study is to assess the correlation between levels of GDF8 in follicular fluid (FF) with outcomes of in vitro fertilization (IVF/ICSI) in women with and without PCOS. A prospective case control study was performed enrolling (40) patients with PCOS and (40) non-PCOS women (male infertility) undergoing IVF/ICSI. The collect

... Show More
Scopus
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of Energy Storage
Effects of non-uniform fin arrangement and size on the thermal response of a vertical latent heat triple-tube heat exchanger
...Show More Authors

View Publication
Scopus (43)
Crossref (40)
Scopus Clarivate Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Composites Science
Sawdust-Based Concrete Composite-Filled Steel Tube Beams: An Experimental and Analytical Investigation
...Show More Authors

Incorporating waste byproducts into concrete is an innovative and promising way to minimize the environmental impact of waste material while maintaining and/or improving concrete’s mechanical characteristics and strength. The proper application of sawdust as a pozzolan in the building industry remains a significant challenge. Consequently, this study conducted an experimental evaluation of sawdust as a fill material. In particular, sawdust as a fine aggregate in concrete offers a realistic structural and economical possibility for the construction of lightweight structural systems. Failure under four-point loads was investigated for six concrete-filled steel tube (CFST) specimens. The results indicated that recycled lightweight co

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jun 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of Curcumin at Various Doses on the Pharmacokinetic Profile of Tacrolimus in Healthy Rabbits
...Show More Authors

The purpose of present study is to evaluate the effect of co-administration of curcumin (CUR) at various doses on the pharmacokinetic (PK) profile of tacrolimus (TAC), a CYP 3A4 substrate in healthy male rabbits. Healthy male rabbits (n=18) were employed in an in vivo, parallel-randomized study. Three groups of rabbits were selected and separated: The rabbits in the first group (control group) received 1 mg/kg TAC orally. Blood samples (1.5-2 mL) were drawn from rabbits' ear marginal veins at the following time frames:  15.0, 30.0, 45.0, 60.0, 90.0, 120.0, 150.0, 180.0 and 300 minutes after TAC administration post dosing and analyzed by using a TAC chemiluminescent enzyme immunoassay (CLIA) detection kit. In the second and third gro

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
THE EFFECT OF SPACE VOLUME ON FREE CONVECTION HEAT TRANSFER FOR ONGITUDINAL FINNED CYLINDER WITH DIFFERENT SLOPE NGLES
...Show More Authors

This study deals with free convection heat transfer for the outer surface of two
cylinders of the shape of (Triangular & Rectangular fined cylinders with 8-fins),
putted into two different spaces; small one with dimension of (Length=1.2m,
height=1m, width=0.9m) and large one with dimension of (Length=3.6m, height =3m,
width=2.7m). The experimental work was conducted with air as a heat transport
medium. These cylinders were fixed at different slope angles (0o, 30o, 60o and 90o)
.The heat fluxes were (279, 1012, 1958, 3005, 4419) W/m2, where heat transferred by
convection and radiation. In large space, the results show that the heat transfer from
the triangular finned cylinder is maximum at a slope angle equals

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Journal Of Engineering
Influence of Design Efficiency of Water Supply Network Inside Building on its Optimum Usage: Review
...Show More Authors

The water supply network inside the building is of high importance due to direct contact with the user that must be optimally designed to meet the water needs of users.  This work aims to review previous research and scientific theories that deal with the design of water networks inside buildings, from calculating the amount of consumption and the optimal distribution of the network, as well as ways to rationalize the use of water by the consumer.  The process of pumping domestic water starts from water treatment plants to be fed to the public distribution networks, then reaching a distribution network inside the building till it is  provided to the user.  The design of the water supply network inside the building is

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Convective Heat Transfer of Fluid Flowing Across a Vertical Plate
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Jul 19 2022
Journal Name
Arabian Journal For Science And Engineering
Investigation of the Impacts of Nanomaterials on the Micromechanical Properties of Gypseous Soils
...Show More Authors

View Publication Preview PDF
Scopus (17)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technolog
Effect Of heat Treatment On The Optical Properties Of CuInSe2 Thin Films
...Show More Authors

CuInSe2(CIS) thin films have been prepared by use vacuum thermal evaporation technique, of thickness750 nm with rate of deposition 1.8±0.1 nm/sec on glass substrate at room temperature and pressure (10-5) mbar. Heat treatment has been carried out in the range (400-600) K for all samples. The optical properties of the CIS thin films are been studied such as (absorption coefficient, refractive index, extinction coefficient, real and imaginary dielectric constant) by determined using Measurement absorption and transmission spectra. Results showed that through the optical constants we can make to control it are wide applications as an optoelectronic devices and photovoltaic applications.

View Publication
Publication Date
Thu Jan 07 2016
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
Effect Of heat Treatment On The Optical Properties Of CuInSe2 Thin Films
...Show More Authors

CuInSe2 (CIS)thin films have been prepared by use vacuum thermal evaporation technique, of 750 nm thickness, with rate of deposition 1.8±0.1 nm/sec on glass substrate at room temperature and pressure (10-5) mbar. Heat treatment has been carried out in the range (400-600) K for all samples. The optical properties of the CIS thin films are been studied such as (absorption coefficient, refractive index, extinction coefficient, real and imaginary dielectric constant)by determined using Measurement absorption and transmission spectra. Results showed that through the optical constants we can made to control it is wide applications as an optoelectronic devices and photovoltaic applications.

Preview PDF