This study was conducted to examine the discharge capacity of the reach of the Tigris River between Kut and Amarah Barrages of 250km in length. The examination includes simulation the current capacity of the reach by using HEC-RAS model. 247cross sections surveyed in 2012 were used in the simulation. The model was calibrated using observed discharges of 533, 800, 1025 and 3000m3/s discharged at Kut Barrage during 2013, 1995, 1995 and 1988, respectively, and its related water level at three gauge stations located along the reach. The result of calibration process indicated that the lowest Root Mean Square Error of 0.095 can be obtained when using Manning’s n coefficient of 0.026, 0.03 for the Kut- Ali Al Garbi and Ali Al Garbi- Amarah reaches respectively, and 0.03 for the flood plain of the whole reach under study. The reach under study has two lateral inflow streams, UmAljury, which joins Tigris River at station 51km, and Aljabab, which joins Tigris River at station 57km. The discharge of Aljabab varies between 0 and 400m3/s and the discharge of UmAljury varies between 0 and 50m3/s. The results showed that the current capacity of the main channel of the reach of the Tigris River between Kut and Amarah Barrages is 400m3/s. The water levels kept less 1m than both levees in case of discharging 1800m3/s from Kut Barrage, with no lateral inflows, and 1700m3/s with lateral inflow. The reach of Tigris River fails to accommodate the flood discharge of 3300m3/s which is the discharge of the flood of 1988 measured at Kut Barage. It can be concluded that the reach had large amount of sediment for the period from 1988 to 2012 and the reach capacity reduced to about half its capacity of 1988 during this period. The results of removing 12 islands and 2 sidebars by reshaping the current condition into trapezoidal cross-section will decrease the surface water levels by 20cm and flow of 1900m3/s can be discharged safely at Kut Barrage without any lateral inflow and 1800m3/s with lateral inflow from the tributaries. While, expand 58 narrow cross-sections that choking the flow, the water levels along the reach are lowered by an average of 20cm in addition to that 20cm when modifying the cross-sections at the islands and sidebars. In this case, flow of 2100m3/s can safely be discharged from Kut Barrage without any lateral inflow and 1900m3/s with lateral inflow. The result when modifying additional 111 cross-sections showed that the reach can safely accommodate a flood wave of 3300m3/s from Kut Barrage without any lateral inflow and 3000m3/s with lateral inflow.
In this present paper, an experimental study of some plasma characteristics in dielectric barrier discharge (DBD) system using several variables, such as different frequencies and using two different electrodes metals(aluminium (Al) and copper (Cu)), is represented. The discharge plasma was produced by an AC power supply source of 6 and 7 kHz frequencies for the nitrogen gas spectrum and for two different electrodes metals(Al and Cu). Optical emission spectrometer was used to study plasma properties (such as electron temperature ( ), electron number density ( ), Debye length ( ), and plasma frequency ( )). In addition, images were analysed for the plasma emission intensity at atmospheric air pressure.
In the present work, the effect of size of zinc dust particles on
AC argon discharge characteristics are investigated
experimentally. The plasma characteristics are determined by
using optical emission spectroscopy (OES) techniques. The
results illustrated that the electron temperature (Te) in the present
and absent of Zinc dust particle is reduced with increasing of
pressure. The electron temperature decreases with increasing of
Zinc dust size. Excitation temperature Tex is reduces with
increasing of Ar pressure in present and absent of zinc dust
particles. The present of Zinc dust reduce the Tex of Ar in both
Zinc dust size. The electron density increasing in the present and
absent of both zinc dust siz
Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreSubjects took physical fitness for health imposed on the area of research that have become an important and clear answer to the many problems resulting from the nature of dealing with modern life current actions that were needed to be hours of manual work has become accomplished by modern technology circumstance minutes, and mediated equipment And machinery. The lack of traffic rights and further burdens the intellectual and psychological pressures and the typical method of work has led to the identification of kinetic activity, thereby threatening public health in many ways stands at the forefront of these threats the problem of smoking, which causes many types of cancers, notably lung cancer. The most important reasons that led to This dr
... Show MoreObjective: To measure the serum levels of Fetuin-A, ischemia-modified albumin (IMA), and ferritin in hospitalized patients with severe COVID-19in Baghdad, Iraq. Moreover, to determine these biomarkers' cut-off valuesthat differentiate between severely ill patients and control subjects. Methods: This case-control study was done from 15 September to the end of December 2021 and involved a review of the files and collectionof blood samples from patients (n=45, group1) hospitalized in COVID-19 treatment centersbecause of severe symptoms compared tohealthy subjects as controls (n=44, group2). Results: Fetuin-A serum levels were not statistically different between patients and controls. In contrast, IMA and ferritin levels were significan
... Show MoreSevere periodontitis is ranked as the sixth most prevalent disease affecting humankind, with an estimated 740 million people affected worldwide. The diagnosis of periodontal diseases mainly relies upon assessment of conventional clinical parameters. However, these parameters reflect past, rather than current, clinical status or future disease progression and, likely, outcome of periodontal treatment. Specific and sensitive biomarkers for periodontal diseases have been examined widely to address these issues and some biomarkers have been translated as point-of-care (PoC) tests. The aim of this review was to provide an update on PoC tests for use in the diagnosis and management of periodontal diseases. Among the PoC tests developed so
... Show MoreIn this work a novel drug delivery system through modification of poly acrylic acid with Methionine as a spacer between the poly acrylic acid which was converted to its acyl chloride and reacted with Methionine as spacer unit which has been reacted with Ampicillin drug. In vitro drug release study had been conducted successfully in basic medium in pH 7.4 and acidic medium in pH 1.1 at 37?. Due to many problems associated with drug release and, this modification could decrease the side effect of drug. The prepared prodrug polymer was characterized by spectra method [FTIR and 1H?NMR]. Physical properties and intrinsic viscosity of drug polymer were determined. The good results were obtained in the presence of spacer unit with compar
... Show MoreAbstract The present work aims to study the performance of reinforced compacted clay soil by sand columns stabilized with sodium silicate to obtain more solid columns than the surrounding soil. The experimental work was carried out by using a lab model to evaluate the performance of both the floating and end bearing sand columns. The results showed that the improvement ratio for the soil reinforced with sand columns stabilized with sodium silicate reached 390% for the type of floating columns and 438% for end bearing columns.