Preferred Language
Articles
/
joe-794
Post-buckling Analysis of Cold-form Steel Column
...Show More Authors

For the time being, the cold-formed sections are widely used due to their simple manufacturing and construction processes. To be feasible, the strength of cold-formed columns should be determined based on their post-buckling behavior. Post-buckling relations are cumbersome and need design aids similar to those of American Iron and Steel Institute (AISI) to be applicable. These design aids have been developed to sections and materials other than those available in the local market. Therefore, this paper tries to develop a general finite element model to simulate the postbuckling behavior of cold-formed steel columns. Shell element has been used to discretize the web, flanges, and lips of the column. A linear bucking analysis with subspace Eigen value scheme has been achieved to determine the global, distortional, and local mode shapes. Subsequently, these modes have been used to generate the correspond imperfections. Finally, the modified Riks method has been used to solve the nonlinear equations of equilibrium and to a void the possible snap through phenomenon. Comparing with the traditional analyses using the effective width method and the direct strength method indicates that the finite element analysis is adequate and can be used for practical applications when dealing with local sections and materials.

Finally, different case studies with different column spans have been considered to show the behavior of the column for different slenderness ratios.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Analysis and Control of PWM Buck-Boost AC Chopper Fed Single-Phase Capacitor Run Induction Motor
...Show More Authors

Single phase capacitor-run induction motors (IMs) are used in various applications such as home appliances and machine tools; they are affected by the sags or swells and any fault that can lead to disturb the supply and make it produce rms voltage below or above the rated motor voltage, which is 220V. A control system is designed to regulate the output voltage of the converter irrespective to the variation of the load and within a specific range of supply voltage variation. The steady-state equivalent circuit of the Buck-Boost chopper type AC voltage regulator, as well as the analysis of this circuit are presented in this paper. Switching device for the regulator is an IGBT Module. The proposed chopper uses pulse width modulation (PWM) c

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Human Sport And Exercise - 2019 - Spring Conferences Of Sports Science
Analysis of some variable kinematical to triple jump world champions for the world championships in 2013
...Show More Authors

View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Fri May 03 2024
Journal Name
Optical And Quantum Electronics
Design and analysis of a dual-core PCF biosensor based on SPR for cancerous cells detection
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Results In Engineering
Stability analysis for the phytoplankton-zooplankton model with depletion of dissolved oxygen and strong Allee effects
...Show More Authors

View Publication Preview PDF
Scopus (14)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Fri Sep 27 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Clinical Assessment and Cytomorphometric Analysis of Buccal Mucosal Cells in Behçet’s Disease Patients
...Show More Authors

Background: Behçet’s disease (BD) is a disorder of systemic inflammatory condition. Its important features are represented by recurrent oral, genital ulcerations and eye lesions. Aims. The purpose of the current study was to evaluate and compare cytological changes using morphometric analysis of the exfoliated buccal mucosal cells in Behçet’s disease patients and healthy controls, and to evaluate the clinical characteristics of Behçet’s disease. Methods. Twenty five Behçet’s disease patients have been compared to 25 healthy volunteers as a control group. Papanicolaou stain was used for staining the smears taken from buccal epithelial cells to be analyzed cytomorphometrically. The image analysis sof

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Oral manifestations, biochemical, and IL-6 analysis of saliva in major depressive disorder patients under treatment
...Show More Authors

Background: Major depressive disorder (MDD) is mental disorder characterized by an all-encompassing low mood accompanied by low self-esteem, and by loss of interest or pleasure in normally enjoyable activities. The aims of the study: were to determine the prevalence of oral manifestation among patients with major depressive disorder receiving antidepressant drugs, and detect alkaline phosphatase (ALP), Total Salivary proteins (TSP), and Interleukin-6 (IL-6) in relation to MDD patients under treatment and to compare with healthy controls. Materials and method: (50) MDD patients; between the ages of 20 years and 60 years.The depression patients are divided into (25) patients under treatment with fluoxetine (Prozac), and (25) patients under tr

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Residual strength and strengthening capacity of reinforced concrete columns subjected to fire exposure by numerical analysis
...Show More Authors
Abstract<p>This study is a numerical investigation of the performance of reinforced concrete (RC) columns after fire exposure. This study aims to investigate the effect of introducing lateral ties and using the RC jacket on improving post-fire behavior of these columns, the effect of the duration of the fire on ultimate load of columns. The analysis was performed through ABAQUS, a 3D – non-linear finite element program. 4 m tall lengthening square RC column with a cross- section of 0.4 m × 0.4 m was used as a test specimen. The RC column was reinforced by 4Ø28 mm longitudinal bars bonded by steel tie bars of Ø10 mm spaced at 400 mm. The firing temperature was increased to 60</p> ... Show More
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jun 05 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Histological and histomorphometric analysis of strontium chloride coated commercially pure titanium implant compared with hydroxyapatite coating
...Show More Authors

Background: In recent years, the immediate loading of dental implants has become more accepted as a standard protocol for the treatment of the edentulous area. Success in implant dentistry depends on several parameters that may improve phenomenon of osseointegration and new bone formation in close contact with the implant. The aim of study was to evaluate the effect of strontium chloride coating of screw shape commercially pure titanium dental implant osseointegration at bone - implant interface by histomorphometric analysis and compare with hydroxyapatite coating at 2 time periods (2 weeks and 6 weeks). Materials and methods: Electrophoretic Deposition Technique (EPD) was used to obtain a uniform coating layer on commercially pure titanium

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering Science And Technology
GEOMETRIC NONLINEAR TIME DOMAIN SPECTRALMATCHING SEISMIC ANALYSIS OF BASE ISOLATED HIGHRISE BUILDINGS INCLUDING P-DELTA EFFECT
...Show More Authors

Time-domain spectral matching commonly used to define seismic inputs to dynamic analysis in terms of acceleration time history compatible with a specific target response spectrum is used in this study to investigate the second-order geometric effect of P-delta on the seismic response of base-isolated high-rise buildings. A synthetic time series is generated by adjusting reference time series that consist of available readings from a past earthquake of the 1940 El Centro earthquake adopted as an initial time series. The superstructure of a 20-story base isolated building is represented by a 3-D finite element model using ETABS software. The results of the base isolated building show that base isolation technique significantly reduces inter-s

... Show More
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Polymeric Membrane Sensors for the Selective Determination of Metoclopramide Hydrochloride and their Applications to Pharmaceutical Analysis
...Show More Authors

Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e

... Show More
View Publication Preview PDF
Crossref