Preferred Language
Articles
/
joe-790
Non-deterministic Approach for Reliability Evaluation of Steel Beam
...Show More Authors

This paper aims to evaluate the reliability analysis for steel beam which represented by the probability of Failure and reliability index. Monte Carlo Simulation Method (MCSM) and First Order Reliability Method (FORM) will be used to achieve this issue. These methods need two samples for each behavior that want to study; the first sample for resistance (carrying capacity R), and second for load effect (Q) which are parameters for a limit state function. Monte Carlo method has been adopted to generate these samples dependent on the randomness and uncertainties in variables. The variables that consider are beam cross-section dimensions, material property, beam length, yield stress, and applied loads. Matlab software has been adopted to generate these pseudo-random variables dependent on its statistical characteristics such as coefficient of variance and probability density function that gathered from a review of literatures.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jun 05 2011
Journal Name
Baghdad Science Journal
Some Probability Characteristics Functions of the Solution of a Stochastic Non-Linear Fredholm Integral Equation of the Second Kind
...Show More Authors

In this research, some probability characteristics functions (probability density, characteristic, correlation and spectral density) are derived depending upon the smallest variance of the exact solution of supposing stochastic non-linear Fredholm integral equation of the second kind found by Adomian decomposition method (A.D.M)

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Engineering, Technology & Applied Science Research
Structural Behavior of Concrete One-Way Slab with Mixed Reinforcement of Steel and Glass Fiber Polymer Bars under Fire Exposure
...Show More Authors

Steel Reinforced Concrete (RC) frequently faces durability problems. In certain areas, Glass Fiber-Reinforced Polymer (GFRP) rebars are considered a non-corrodible substitute for steel reinforcement. Elevated temperatures have a significant impact on the mechanical characteristics and the adhesiveness of GFRP rebars to concrete, particularly when the polymeric matrix's glass transition temperature is approached or surpassed. Three simply supported reinforced concrete slabs were considered in the experimental program. Each specimen had identical dimensions of 1500×540×120 mm. For the fire resistance requirements, a 45 mm clear concrete cover and an exception of a 200 mm unexposed (cool) anchor zone at the ends were considered. The

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of The Mechanical Behavior Of Materials
Structural behavior of one-way slabs reinforced by a combination of GFRP and steel bars: An experimental and numerical investigation
...Show More Authors
Abstract<p>Glass- fiber-reinforced polymer (GFRP) offers a significant alternative to steel in reinforced concrete, with superior corrosion and fire resistance. Though less ductile and more brittle in stress–strain behavior than steel, it is very helpful to combine GFRP with steel reinforcement that improves the structural behavior. This research investigates the flexural characteristics of a one-way slab reinforced by a combination of GFRP and steel reinforcement. Three identical concrete slabs ((1500 × 550 × 120) mm and 43 MPa) were tested under static load with GFRP replacement ratios of (0, 20, and 40)%. The experimental data were utilized to verify a numerical model. The experimen</p> ... Show More
View Publication
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Mon Jun 01 2026
Journal Name
Egyptian Journal Of Agronomy
Field Performance Evaluation of Spring - Loaded Cultivator
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Sep 05 2020
Journal Name
Al-kindy College Medical Journal
Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesisMethods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and

... Show More
Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Evaluation of Textile Filter in Field Drains
...Show More Authors

The role of drain in agricultural lands is to remove excess surface and subsurface water to create a good environment for root growth and to increase crops yield. The main objective of this research was to evaluate the performance of closed drains when using textile filter instead of crushed gravel filter. The research has been executed in the laboratory using a sand tank model and by using two types of the soil. One of soils was light soil (sandy soil) and the other heavy soil (loamy soil). The tests were classified into four cases; each case was supplied discharge during 10 days. The results showed that the amount of out flow when using graded crushed gravel filter is greater than the amount of out flow in case of usin

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 05 2020
Journal Name
Al-kindy College Medical Journal
Evaluation Aseptic Loosening of Primary Hip Arthroplasty
...Show More Authors

Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Evaluation of Medication Errors in Hospitalized Patients
...Show More Authors

Objectives: Many medication errors occur in the hospital, and these can endanger patients. The purpose of this study was to evaluate the incidence of medication errors in hospitalized patients, and to categorize the most frequent types of errors, and to asses the possible measures that may prevent the occurrence of such errors.
Methods: A prospective, exploratory, and evaluative study, using direct observation method to detect medication errors in adult hospitalized patients in medical and surgical units in Baquba Teaching Hospital- Diyala-Iraq.. The files of 299 patients had been reviewed from July 2009 to September 2009, including medication orders and treatment sheets to detect existing errors. The detected errors were recorded and

... Show More
View Publication Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
Design and Evaluation of a Polarizer Filter
...Show More Authors

This research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.

View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Feb 23 2023
Journal Name
Chalcogenide Letters
Fabrication and evaluation of CuAlSe2/Si photodetector
...Show More Authors

In this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref