Preferred Language
Articles
/
joe-784
Evaluation of Fatigue Behavior of Epoxy Coatings used for Potable Water Storage Tanks
...Show More Authors

In this paper, three types of epoxy-based coatings (Polyamide, pure Polyamine, and Polyamine reinforced by glass-flake) used as a lining for potable water tanks were studied using experimental and finite element methods. Tensile, impact, and fatigue tests were conducted on uncoated and coated AISI 316 stainless steel. The test results show that the applied epoxy based coating improves the mechanical properties, increases of fatigue crack resistance, and enhance the dynamic fracture toughness. The fatigue crack propagation is influenced by the compositions of epoxy coating, and the glass-flake improves the coating resistance to fatigue crack propagation compared to other types.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of Engineering
Evaluation of Alum/Lime Coagulant for the Removal of Turbidity from Al- Ahdab Iraqi Oilfields Produced Water
...Show More Authors

The removal of turbidity from produced water by chemical coagulation/flocculation method using locally available coagulants was investigated. Aluminum sulfate (alum) is selected as a primary coagulant, while calcium hydroxide (lime) is used as a coagulant aid. The performance of these coagulants was studied through jar test by comparing turbidity removal at different coagulant/ coagulants aid ratio, coagulant dose, water pH, and sedimentation time. In addition, an attempt has been made to examine the relationship between turbidity (NTU) and total suspended solids (mg/L) on the same samples of produced water. The best conditions for turbidity removal can be obtained at 75% alum+25% lime coagulant at coagulant dose of 80 m

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 25 2017
Journal Name
Al-khwarizmi Engineering Journal
A new Cumulative Damage Model for Fatigue Life Prediction under Shot Peening Treatment
...Show More Authors

 Abstract

In this paper, fatigue damage accumulation were studied using many methods i.e.Corton-Dalon (CD),Corton-Dalon-Marsh(CDM), new non-linear model and experimental method. The prediction of fatigue lifetimes based on the two classical methods, Corton-Dalon (CD)andCorton-Dalon-Marsh (CDM), are uneconomic and non-conservative respectively. However satisfactory predictions were obtained by applying the proposed non-linear model (present model) for medium carbon steel compared with experimental work. Many shortcomings of the two classical methods are related to their inability to take into account the surface treatment effect as shot peening. It is clear that the new model shows that a much better and cons

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 02 2021
Journal Name
Journal Of Engineering Science And Technology
INVESTIGATING THE EFFECT OF INLET APERTURE AND BAFFLE POSITION IN IMPROVING THE EFFICIENCY OF PRIMARY SETTLING TANKS
...Show More Authors

Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Effect ofweight percentage chopped carbon fibers on the mechanism of cracks propagation for Epoxy composites
...Show More Authors

In this research, the mechanism of cracks propagation for epoxy/ chopped carbon fibers composites have been investigated .Carbon fibers (5%, 10%, 15%, and 20%) by weight were used to reinforce epoxy resin. Bending test was carried out to evaluate the flexural strength in order to explain the mechanism of cracks propagation. It was found that, the flexural strength will increase with increasing the percentage weight for carbon fibers. At low stresses, the cracks will state at the lower surface for the specimen. Increasing the stresses will accelerate the speed of cracks until fracture accorded .The path of cracks is changed according to the distributions of carbon fibers

View Publication Preview PDF
Publication Date
Mon Mar 18 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of optimal shot peening time on fatigue life for aluminum alloy 6061-T651
...Show More Authors

The compressive residual stresses generated by shot peening, is increased in a direct proportional way with shot peening time (SPT). For each metal, there is an optimum shot peening time (O.S.T) which gives the optimum fatigue life. This paper experimentally studied to optimize shot peening time of aluminium alloy 6061-T651 as well as using of and analysis of variance (ANOVA).

Two types of fatigue test specimens’ configuration were used, one without notch (smooth) and the other with a notch radius (1,25mm), each type was shot peened at different time. The (O.S.T) was experimentally estimated  to be 8 minutes reaching the surface stresses at maximum peak of -184.94 MPa.

A response surface methodology (RSM) is presen

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
content Analysis for Some Type of Pillows used in Iraqi houses
...Show More Authors

content Analysis for Some Type of Pillows used in Iraqi houses

View Publication Preview PDF
Publication Date
Sun Sep 06 2015
Journal Name
Baghdad Science Journal
Evaluation of the level of Some Heavy Metals in Tobacco of Domestic and Imported Cigarette Brands Used in Iraq
...Show More Authors

Smoking-related diseases can be attributed to the inhalation of many different toxins, including heavy metals, which have a host of harmful health effects. The primary objective of this study was to determine whether local and imported cigarette brands used in Iraq , have they elevated levels of metals or not .Three metals Lead (Pb) , Cadmium (Cd) and Chromium(Cr) were determined in tobacco of seventeen brands of imported cigarettes commonly available in Iraq and three Iraqi domestic cigarettes , which were randomly taken from retail market in Baghdad by using flame atomic absorption spectrometry. The produced data of imported and local cigarette brands were discussed and compared together and with studies from elsewhere .The result

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Jul 01 2017
Journal Name
Energy Procedia
Epoxy/Silicone Rubber Blends for Voltage Insulators and Capacitors Applications
...Show More Authors

View Publication
Scopus (39)
Crossref (34)
Scopus Clarivate Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Improving Fatigue Life of Bolt Adapter of Prosthetic SACH Foot
...Show More Authors

In this research an analysis for improving the fatigue behavior (safety factor of fatigue) of non- articular prosthetic foot (SACH) in the region (Bolt Adapter).The laser peening was carried to the fatigue specimens to improving the fatigue properties of bolt’s material. The tests of mechanical properties and fatigue behavior were carried for material that the bolt manufacture from it, a region where the failure occur and inserted of these properties to the program of engineering analysis (Ansys) to calculate the safety factor of fatigue. The results showed that the safety factor after hardening by laser is increased by 42.8%.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-khwarizmi Engineering Journal
Morphology and Mechanical Properties of (Epoxy/PVC) Blend
...Show More Authors

Abstract

     In this research, the morphology and mechanical properties of (Epoxy/PVC) blend were investigated.  (EP/PVC) blend was prepared by manual mixing of epoxy resin with different weight ratios of (Poly vinyl chloride (PVC) after dissolving it in cyclohexanon). Five sheets of polymer blends in wt% included (0%, 5%, 10%, 15% and 20%) of PVC were prepared at room temperature. Tests were carried out to study some mechanical properties for these blends and compared with the properties of pure epoxy. The morphology of the prepared materials was examined to study the compatibility nature between the two polymers under work. It was found that the best ratio of addition is (20%) of PVC.

... Show More
View Publication Preview PDF