Preferred Language
Articles
/
joe-735
Heat Transfer Analysis of Conventional Round Tube and Microchannel Condensers in Automotive Air Conditioning System
...Show More Authors

In this paper, an experimental analysis of conventional air-cooled and microchannel condensers in automotive vapor compression refrigeration cycle concerning heat transfer coefficient and energy using R134a as a refrigerant was presented. The performance of two condensers and cycles tested regarding ambient temperature which it was varied from 40oC to 65oC, while the indoor temperature and load have been set to be 23oC and 2200 W respectively. Results showed that the microchannel condenser has 224 % and 77 % higher refrigerant side and air side heat transfer coefficient respectively than the coefficients of the conventional condenser. Thus, the COP, in case of using the microchannel condenser, was found to be 20 % higher than that of the conventional cycle. Also, the microchannel condenser has a 50 % smaller volume than the conventional. Therefore, it provides more space in the car engine container occupied with other components.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Oct 17 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparison Between the Methods Estimate Nonparametric and Semiparametric Transfer Function Model in Time Series Using Simulation
...Show More Authors

Publication Date
Fri Jun 30 2023
Journal Name
The International Tinnitus Journal
Adenoidectomy and Endoscopic Myringotomy with and without ventilation tube insertion for Treatment of Otitis Media with Effusion in 6-12 years old Children
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (4)
Scopus Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Environmental Engineering And Science
Performance evaluation of coronavirus closure on air quality over central, southern and northern parts of Iraq
...Show More Authors

When the number of confirmed coronavirus disease cases rose in Iraq in the middle of February 2021, the Iraqi government performed a closure approach to constrain mobility and factory operations and enforce social distancing. In this research, the concentrations of air components (PM2.5, PM10, nitrogen dioxide (NO2) and ozone (O3)), which represent herein the degree of air quality index, were recorded, drawn and evaluated over central (Baghdad, the capital), northern (Kirkuk Province) and southern (Basra Province) Iraq before and during the closure. The experimental duration of this research was 6 months (from 1 January 2021 to 30 June 2021), which

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jan 13 2024
Journal Name
Journal Of Advanced Research In Fluid Mechanics And Thermal Sciences
Influence of Surrounding Air Temperature and Humidity upon the Performance of a Gas Turbine Power Plant
...Show More Authors

Nowadays, energy demand continuously rises while energy stocks are dwindling. Using current resources more effectively is crucial for the world. A wide method to effectively utilize energy is to generate electricity using thermal gas turbines (GT). One of the most important problems that gas turbines suffer from is high ambient air temperature especially in summer. The current paper details the effects of ambient conditions on the performance of a gas turbine through energy audits taking into account the influence of ambient conditions on the specific heat capacity ( , isentropic exponent ( ) as well as the gas constant of air . A computer program was developed to examine the operation of a power plant at various ambient temperature

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Wed Dec 31 2014
Journal Name
Al-khwarizmi Engineering Journal
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
...Show More Authors

Abstract

    This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season.     The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m

... Show More
View Publication Preview PDF
Publication Date
Wed May 15 2024
Journal Name
Iraqi Journal Of Applied Physics
Effect of Solvent on Spectroscopic Characteristics and Energy Transfer Processes of Some Laser Dyes
...Show More Authors

Scopus (1)
Scopus
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Micro and Nano Material on Critical Heat Flux (CHF) Enhancement
...Show More Authors

The Nano materials play a very important role in the heat transfer enhancement. An experimental investigation has been done to understand the behaviors of nano and micro materials on critical heat flux. Pool boiling experiments have used for several concentrations of nano and micro particles on a 0.4 mm diameter nickel chrome (Ni-Cr) wire heater which is heated electrically at atmospheric pressure. Zinc oxide(ZnO) and silica(SiO2) were used as a nano and micro fluids with concentrations (0.01,0.05,0.1,0.3,0.5,1 g/L), a marked enhancement in CHF have been shown in the results for nano and micro fluids for different concentrations compared to distilled water. The deposition of the nano particles on the heater surface was the rea

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Evaluation of Air Pollution Tolerance Index (APTI) by two species of terrestrial plants in some stations within Babylon Province, Iraq
...Show More Authors

This study deals with air pollution tolerance index (APTI) and anatomical variation in leaves of two species of terrestrial plants Ficus sp. and Conocarpus sp. that have bee commonly the separated along roadsides in many stations within Babylon province. APTI values of both species were less than 10 during study period which represented sensitivity of these plants to air pollution. There are Anatomical responses to pollution in the leaves of both studied species. Main adaptations included increased thickness of parenchyma cell walls with clear dark deposits in sections of Ficus sp. from sections of stations 2 and 4 which represent polluted stations. Conocarpus sp. main adaptation included stomata increased in density and decreased in size w

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed May 10 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Study for Charge Transfer Complexes Between p- Chloranil with Anions of Amide, Azide and Cyanide
...Show More Authors

    The complexes of para-chloranil as electron acceptor and the anions of amide, azide and cyanide as electron donors in aqueous ethanol as a solvent, were studied spectrophotometrically .     The reactions lead to the formation of charge transfer complexes. The CT complexes were stable in excess acceptor concentration, while they were underwent another transformations in excess donors concentrations.   Stoichiometries were determined, the molecular ratio was determined by continuous variation method (Job method) and is was  1:1 (donor: acceptor).   The maximum wavelength (λ max.), the energy (hÏ…CT), ionization potential (Ip) and activation energy (w ) of excited state f

... Show More
View Publication Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental Investigation for TiO2 nanoparticles as a Lubricant-Additive for a Compressor ofWindow Type Air-Conditioner
...Show More Authors

The coefficient of performance of a window type Air-Conditioner system can be improved if a reduction in the work of compressor can be achieved by a suitable technique. The present study investigates the effect of dispersing a low concentration of TiO2 nanoparticles in the mineral oil based lubricant, as well as on the overall performance of a window type Air-Conditioner system using R22 as the working fluid. An enhancement in the COP of the refrigeration system has been observed and the existence of an optimum volume fraction noticed, with low concentrations of nanoparticles suspended in the mineral oil. Results showed that the average compressor work reduced by 13.3%, which ultimately resulted in an increase of 11.99% in the COP due to

... Show More
View Publication Preview PDF
Crossref (4)
Crossref