The effect of air injection device on the performance of airlift pump used for water pumping has been studied numerically and experimentally. An airlift pump of dimensions 42mm diameter and 2200 mm length with conventional and modified air injection device was considered. A modification on conventional injection device (normal air-jacket type) was carried out by changing injection angle from 90 (for conventional) to 22.5 (for modified). Continuity and Navier-Stokes equations in turbulent regime with an appropriate two-phase flow model (VOF) and turbulent model ( ) in two dimensions axisymmetry flow were formulated and solved by using the known package FLUENT version (14.5). The numerical and experimental investigations were carried out for both conventional and unconventional air-jackets at submergence ratio of 0.75 and air mass flow rate from 0.5, 2, 10, 50 and 85 kg/hr. Comparisons between the numerical and experimental results for both injection devices were made and fair agreements were found and the main results showed that the performance and maximum efficiency of airlift pump is increased for higher mass flow rate of injected air for the tested submergence ratio using unconventional airjacket
performance with average enhancement were 9% and 10% for performance and maximum efficiency respectively.
A theoretical and protection study was conducted of the corrosion behavior of carbon steel surface with different concentrations of the derivative (Quinolin-2-one), namly (1-Amino-4,7-dimethyl-6-nitro-1H-quinolin-2-one (ADNQ2O)). Theoretically, Density Functional Theory (DFT) of B3LYP/ 6-311++G (2d, 2p) level was used to calculate the optimized geometry, physical properties and chemical inhibition parameters, with the local reactivity to predict both the reactive centers and to locate the possible sites of nucleophilic and electrophilic attacks, in vacuum, and in two solvents (DMSO and H2O), all at the equilibrium geometry. Experimentally, the inhibition efficiencies (%IE) in the saline solution (of 3.5%) NaCl were st
... Show MoreBackground: Visfatin is a novel adipokine that mainly secreted by visceral adipose tissue, had an important role in inflammation and immune system. Creatine Kinase (CK) which is an enzyme that is involved in energy metabolism, found in large amounts in myocardium, brain and skeletal tissues. This study is carried out To evaluate the periodontal health status of the study groups (chronic periodontitis and chronic periodontitis with coronary atherosclerosis) and control groups, to measure the salivary levels of visfatin and Creatine Kinase in these groups and compare between them, and to determine the correlations between salivary visfatin and Creatine Kinase levels with the periodontal parameters in the three groups. Materials and Methods: e
... Show MoreAn essential issue in obstetrics is the prevalence of maternal and fetal complications in pregnant women with polycystic ovary syndrome (PCOS). The purpose of the present study was to investigate the prevalence of pregnancy complications among various phenotypes of pregnant women with PCOS.
To enhance the structural performance of concrete-filled steel tube (CFST) columns, various strengthening techniques have been proposed, including the use of internal steel stiffeners, external wrapping with carbon fiber-reinforced polymer (CFRP) sheets, and embedded steel elements. However, the behavior of concrete-filled stainless-steel tube (CFSST) columns remains insufficiently explored. This study numerically investigates the axial performance of square CFSST columns internally strengthened with embedded I-section steel profiles under biaxial eccentric loading. Finite element (FE) simulations were conducted using ABAQUS v. 6.2, and the developed models were validated against experimental results from the literature. A comprehen
... Show MoreSteady natural convection in a square enclosure with wall length (L= 20 cm) partially filled by saturated porous medium with same fluid (lower layer) and air (upper layer) is investigated. The conceptual study of the achievements of the heat transfer is performed under effects of bottom heating by constant heat flux (q=150,300,450,600W/m2 ) for three heaters size (0.2,0.14,0.07)m with symmetrically cooling with constant temperature on two vertical walls and adiabatic top wall. The relevant filled studied parameters are four different porous medium heights (Hp=0.25L,0.5L, 0.75L, L), Darcey number (Da1) 3.025×10-8 and (Da2) 8.852×10-4 ) and Rayleigh number range (60.354 - 241.41), (1.304×106 – 5.2166×106 ) for Da1 and Da2 cases respecti
... Show More
