Due to the deliberate disposal of industrial waste, a great amount of petroleum hydrocarbons pollute the soil and aquatic environments. Bioremediation that depends on the microorganisms in the removal of pollutants is more efficient and cost-effective technology. In this study, five rhizobacteria were isolated from Phragmites australis roots and exposed to real wastewater from Al-Daura refinery with 70 mg/L total petroleum hydrocarbons (TPH) concentration. The five selected rhizobacteria were examined in a biodegradation test for seven days to remove TPH. The results showed that 80% TPH degradation as the maximum value by Sphingomonas Paucimobilis as identified with Vitek® 2 Compact (France).
capable of the measuring with a high degree of precision in a single instrument. Total stations device are used for station setting up, setting-outmany points from one station. Their major purpose of this work is to take advantage of total station for setting up building and to establish 3D representation using AutoCAD program. The area of the study was Civil Engineering Department at Baghdad University campus AL Jadiriyah. The completion of the work is done in two stages; 1. The field work: In this stage, the Total Station Nikon Nivo-5C was selected for the current study. This device was measured horizontal and vertical distance, elevations, and coordinates from a single set up. This data directly stored on memory. 2. The office work: In t
... Show MoreSurficial sediment samples were collected from four stations at Shatt Al-Hilla from Western Zoer area to Almaimirh in Babylon province for the period from August 2016 to April 2017.The level of contamination in the sediments of Shatt Al-Hilla, by Lead (Pb), Copper (Cu), Nickle (Ni), Manganese (Mn), Zinc (Zn), Arsenic (As), and Cobalt (Co) has been evaluated using the index of Geo-accumulation (I-Geo), Contamination factor (CF), pollution load index (PLI) and Potential ecological risk index (Eire). In the present study the levels of heavy metals in sediment samples were found in the range of (10-15.22 ppm) for Pb, (25.6-46.09 ppm) for Cu,(144.9-413.7 ppm) for Ni, (666.1- 906.3 ppm) for Mn, (68.69- 119.2 ppm) for Zn, for As (5.22- 8.25 ppm
... Show MoreThe concerns about water contaminants affect most developing countries bypassing rivers over them. The issue is challenging to introduce water quality within the allowed limits for drinking, industrial and agricultural purposes. In the present study, physical-chemical parameters measurements of water samples taken from eleven stations were collected during six months in 2020 through flow path along the whole length of Tigris River inside AL Kut city (center of Wassit government) were investigated for six parameters are total hardness TH, hydrogen ion pH, biological oxygen demand BOD5, total dissolved solids TDS, nitrate NO3, and sulfate SO4. The water quality analysis results were compared with the maximum allowable limit concentrat
... Show MoreArsenic is a prevalent and pervasive environmental contaminant with varied amounts in drinking water. Arsenic exposure causes cancer, cardiovascular, liver, nerve, and ophthalmic diseases. The current study aimed to find the best conditions for eliminating arsenic from simulated wastewater and their effect on biomarkers of hepatic in mice. Adsorption tests including pH, contact duration, Al-kheriat dosage, and arsenic concentrations were evaluated. Seventy-two healthy albino mice (male) were accidentally allocated into nine groups (n = 8), the first group was considered as healthy control, the second group (AL-Kheriat), and other groups received AL-Kheriat and arsenic 25, 50, 75, 100, 125, 150 and 175 mg/kg, respectively. Next 10 days, the
... Show MoreGeographic information system (GIS) is utilized in a variety of tasks such as, resource management, urban planning, emergency planning in case of accident, and rapid response etc. The aim of this study is to produce a digital map with the aid of GIS and a survey data. A survey data is conducted with Total Station technique on sanitary planning positions. The campus of Baghdad University is chosen to test the execution and accuracy of the results for sewer manholes locations. During the field survey, Total Station (Nikon Nivo) is used to identify the 3-D coordinates for each location. Finally, Geographical Information System (GIS) are utilized to present the digital map of the network sewer pipe line to the end users. Although Geographic Inf
... Show MoreHistidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa
... Show MoreTo assess the total hip replacement patients’ knowledge of home – care regarding pain management, medication therapy, wound care, mobility limitation and complications may occur in the post hip replacement surgery, and to assess relationship between some variables such as, age level of education, sex & marital status with home- care knowledge. A descriptive study was used to assess the hip-replacement patient home-knowledge, a purposive sampling of (60) hip-replaced –patients were selected from Gazy Alhariri Hospital (central of surgical profession ) and Alwasity Hospital ( plastic surgery) , the questionnaire obtains two parts , part one, which included socio-demographical characteristics of the samp
... Show MoreAbstract
The current study was conducted to assess the effect of advancing age on total serum IgE level in asthmatic patients. To this purpose, 90 asthmatic patients and 30 healthy individuals ( control group ) were enrolled. Asthmatic patients were categorized into four groups. Group A consisted of asthmatic patients (9) whose age was more than 20 and up to 30 y. Group B contained asthmatics (13) of age more than 30 and up to 40 y. Group C comprised those (23) of more than 40 and up to 50 y. Group D consisted asthmatic patients (45) of age more than 50 y. Total serum IgE level significantly changed in group D patients when compared with those of
In this research a local adsorbent was prepared from waste tires using two-step pyrolysis method. In the carbonization process, nitrogen gas flow rate was 0.2L/min at carbonization temperature of 500ºC for 1h. The char products were then preceded to the activation process at 850°C under carbon dioxide (CO2) activation flow rate of 0.6L/min for 3h. The activation method produced local adsorbent material with a surface area and total pore volume as high as 118.59m2 /g and 0.1467cm3/g, respectively. The produced . local adsorbent (activated carbon) was used for adsorption of lead from aqueous solution. The continuous fixed bed column experiments were conducted. The adsorption capacity performance of prepared activated carbons in this work
... Show More