Preferred Language
Articles
/
joe-68
Remediation of Contaminated Soil with Petroleum Industrial Wastewater
...Show More Authors

The contamination of soil with the wastes of oil industry products that are complex mixtures of hydrocarbons increased recently due to the large development of oil industries in Iraq. This study deals with the remediation of low permeability contaminated clayey soil by using the enhanced electrokinetic technique (EK). The contaminated soil samples obtained from Thi-Qar oil refinery plant in Al-Nassyriah city, where the byproducts of refinery plant are disposed into that site. The byproduct contaminant treated as total petroleum hydrocarbons (TPH) to avoid dealing and complexity of treating the individual minerals and compounds consisting the contaminant. The initial concentrations of TPH were (702.7, 1168, 1235) ppm in the contaminated soil samples NA10, NA11, and NA12  respectively. The remediation technique includes a bench-scale experimental study by applying the enhanced electrokinetic test on the soil sample NA12  that contains the higher concentration of TPH in compared with other soil samples. A constant DC voltage gradient of 1.0 VDC/cm was applied for a period of 10 days. This  echnology was enhanced by using flushing solution of ethanol and deionized water, which was mixed in ratios of 30% and 70% respectively. The results of this study showed that the removal of TPH at the anode was about 15% and the concentration of TPH decreased at anode, which reflect the migration of TPH towards the cathode.
 
 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2013
Journal Name
Http://www.i-csrs.org/volumes/gisars/vol.3/vol.3.1.1.july.12.pdf
Remote sensing technique to monitoring the risk of soil degradation using NDVI
...Show More Authors

In order to take measures in controlling soil erosion it is required to estimate soil loss over area of interest. Soil loss due to soil erosion can be estimated using predictive models such as Universal Soil Loss Equation (USLE). The accuracy of these models depends on parameters that are used in equations. One of the most important parameters in equations used in both of models is (C) factor that represents effects of vegetation and other land covers. Estimating land cover by interpretation of remote sensing imagery involves Normalized Difference Vegetation Index (NDVI), an indicator that shows vegetation cover. The aim of this study is estimate (C) factor values for Part of Baghdad city using NDVI derived from satellite Image of Landsat-7

... Show More
View Publication
Publication Date
Wed Sep 28 2022
Journal Name
Journal Of The College Of Education For Women
The Level of Aligning Scientific Research in Omani Universities with the Era of the Fourth Industrial Revolution in the Light of Oman’s 2040 vision and the Ways of its Development
...Show More Authors

The current research aims to reveal the reality of coping the scientific research in Omani universities in the Sultanate of Oman with the requirements of the Fourth Industrial Revolution in the light of Oman’s 2040 vision. It also aims derive some suggestions to develop the scientific research in these institutions. The study has adopted a qualitative approach in which interviews were conducted. The sample consisted of (16) leaders of governmental and private higher education institutions, as well as, some experts in the field of Fourth Industrial Revolution. The theoretical significance of the study is represented by its response to Oman’s vison in 2040. It is further in line with the previous international reports and educational s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Environmental Engineering And Management Journal
TREATMENT OF DAIRY WASTEWATER BY ELECTROCOAGULATION AND ULTRASONIC-ASSISTED ELECTROCOAGULATION METHODS
...Show More Authors

View Publication
Crossref (6)
Crossref
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Oily Wastewater Treatment Using Expanded Beds of Activated Carbon and Zeolite
...Show More Authors

Two types of adsorbents were used to treat oily wastewater, activated carbon and zeolite. The removal efficiencies of these materials were compared to each other. The results showed that activated carbon performed some better properties in removal of oil. The experimental methods which were employed in this investigation included batch and column studies. The former was used to evaluate the rate and equilibrium of carbon and zeolie adsorption, while the latter was used to determine treatment efficiencies and performance characteristics. Expanded bed adsorber was constructed in the column studies. In this study, the adsorption behavior of vegetable oil (corn oil) onto activated carbon and zeolite was examined as a function of the concentr

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Evaluating the Efficiency of some Wastewater Treatment Plants in Najaf Governorate
...Show More Authors
Abstract<p>Although there are many wastewater treatment plants, we still suffer from many problems resulting from a lack of experience or technical operating problems. In this research, the service’s efficiency is evaluated according to the design laws required for small factories in the province of Najaf, which works with filtering technology through point filtration, the old project in the Al-Baraka plant, and the second works. Within the biological treatment mbbr + activated sludge, which is a biomass technology where samples were taken from both plants and annual values of the pollutant rate after treatment in the old Al-Baraka plant project COD 64 mg/L and the demand for biochemical oxyge</p> ... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
REMOVAL OF OIL FROM WASTEWATER BY ADVANCED OXIDATION PROCESS / HOMOGENEOUS PROCESS
...Show More Authors

In the present work advanced oxidation process, photo-Fenton (UV/H2O2/Fe+2) system, for the treatment of wastewater contaminated with oil was investigated. The reaction was influenced by the input concentration of hydrogen peroxide H2O2, the initial amount of the iron catalyst Fe+2, pH, temperature and the concentration of oil in the wastewater. The removal efficiency for the system UV/ H2O2/Fe+2 at the optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=3, temperature =30o C) for 1000mg/L load was found to be 72%.

View Publication Preview PDF
Crossref (12)
Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Effecting of pH Parameter on Simulated Wastewater Treatment Using Electrocoagulation Method
...Show More Authors

The aim of the present research is to investigate the effecting of pH parameter on the feasibility of lead removal from simulated wastewater using an electrochemical system. Electrocoagulation method is one of electrochemical technology which is used widely to treat industrial wastewater. Parameters affecting this operation, such as initial metal concentration, applied current, stirrer speed, and contact time of electroprocessing were taken as 155ppm, 1.5 Ampere, 150 rpm, 60 minutes respectively. While pH of the simulated wastewater was in the range of  2 to 12 in the experiments. It was found from the results that pH is an important parameter affecting lead removal operation. The best value of pH parameter is appro

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (16)
Scopus Crossref
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
REUSE OF DOMESTIC WASTEWATER FOR IRRIGATION: CONCEPTUAL AND BASIC DESIGN ELEMENTS
...Show More Authors

In Iraq, water shortages and drought, especially during the hot summer months, necessitates that municipal authorities adopt water reuse projects like reusing treated domestic wastewater for crop irrigation. This work gives the conceptual and basic design elements for the necessary steps of filtration, UV irradiation and chlorination to make such a wastewater fit for agricultural use. A typical rural community of 50,000 people is considered as an example case for which functionality and relative simplicity of the proposed designs are prime factors. The objectives are 1) to show what is required and 2) that the presented information may be utilized to embark on the following phases of detailed design and execution of such projects.

View Publication Preview PDF
Publication Date
Thu Aug 05 2021
Journal Name
International Journal Of Renewable Energy Development
Desalination of Agricultural Wastewater by Solar Adsorption System: A Numerical Study
...Show More Authors

There are still areas around the world suffer from severe shortage of freshwater supplies. Desalination technologies are not widely used due to their high energy usage, cost, and environmental damaging effects. In this study, a mathematical model of single-bed adsorption desalination system using silica gel-water as working pair is developed and validated via earlier experiments. A very good match between the model predictions and the experimental results is recorded. The objective is to reveal the factors affecting the productivity of fresh water and cooling effect in the solar adsorption system. The proposed model is setup for solving within the commercially-available software (Engineering Equation Solver). It is implemented to so

... Show More
View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Biotreatment of AL-KARAMA Teaching Hospital Wastewater Using Aerobic Packed Bed
...Show More Authors

This study is aimed to use the aerobic packed bed in biotreatment of the wastewater which is discharge from AL-KARAMA teaching hospital in Baghdad. The performance of packed-bed treatment method was examined for elimination of the organic compounds from wastewater under aerobic conditions. In this research different parameters were studied. They were: inoculums concentration, circulation rate of wastewater through the bed, packing type and the temperature. Results showed that the system efficiently removed about 82% of the chemical oxygen demand (COD) and 80% of the Biological oxygen demand (BOD). Percent reduction in turbidity was about 92% and reduction in nitrate concentration was about 87%. It was found that best performance of the pack

... Show More
View Publication Preview PDF
Crossref