Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) device is used to obtain photos of a board including (23) ground control points on it, those observed from two stations and adjusted by using equations of the 3D adjusted triangulation networks by lengths and angles (hybrid routine). (10) GCPs and (13) checkpoints were used to compare the Root Mean Square Error (RMSE) of checkpoints that result from using laser scan cameras with (RMSE) of the same checkpoints that result from using digital photos (Nikon 5200D).

The result of (RMSE) comparison was ) in the X direction, ) in the Y direction and ) in the Z direction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
The influence of He-Ne Laser (632.8 nm) on Candida albicans isolated from complete upper dentures: In vitro study
...Show More Authors

The main objective of this study is to determine whether the use of He-Ne Laser (632.8 nm wavelength and power 0.5 mW) is an eligible and effective tool to kill or reduce the cell viability of Candida albicans isolated from complete upper dentures. Twenty one swabs were taken from the complete upper dentures. Only six swabs showed positive cultures for C. albicans. The isolate was divided into two groups, group I was not irradiated (control), and group II was irradiated by He-Ne Laser for different periods (10, 15, 20, and 30) min. After irradiation, the results showed a significant reduction in the viable cell count and colonies diameters especially at exposure periods 10 and 15 min. Although the low power He-Ne Laser was not eradicating t

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition
...Show More Authors

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for SnO2 doped ZnO prepared by pulse Nd:YAG laser deposition
...Show More Authors

 In this work, plasma parameters such as (electron temperature (Te), electron density (ne), plasma frequency (fp) and Debye length (λD)) were studied using spectral analysis techniques. The spectrum of the plasma was recorded with different energy values, SnO2 and ZnO anesthetized at a different ratio (X = 0.2, 0.4 and 0.6) were recorded. Spectral study of this mixing in the air. The results showed electron density and electron temperature increase in zinc oxide: tin oxide alloy targets. It was located  that  The intensity of the lines increases in different laser peak powers when the laser peak power increases and then decreases when the force continues to increase.

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
A Comparison between Er,Cr:YSGG 2780 nm Laser and Carbide Fissure Bur in Root-End resection
...Show More Authors

Aim: The Aim of the study is to compare between Er,Cr:YSGG 2780 nm laser and carbide fissure bur in root-end resection regarding the morphological variations, temperature changes and the duration of resection process.

Settings and Design: 5 W, 25 Hz, 50% water, 80% air,25.47 J/cm2 .

Material and method: twenty-one extracted single rooted teeth endodontically were treated, twenty teeth were obturated and divided into two groups according to method of resection. Group 1 root-end resected using cross cut carbide bur while group 2 root-end resected using laser with MGG6 sapphire tip of 600 μm diameter. Temperature on external root surface and duration of resection were recor

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 12 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The role of low level laser therapy on the expression of IL_1 beta in wound healing
...Show More Authors

Background: Low-level laser therapy (LLLT) has been extensively applied to improve wound healing due to some biostimulatory properties presented by laser arrays apparently able to accelerate the repair of soft tissue injuries. However, the role of proinflammatory interlukines not been studied yet. IL_1 ? represent one of the most important poroinflammatory interlukines that involved in wound healing. The goal of this study was to investigate the effect of 790-805nm diode laser on the expression of IL_1 ? during wound healing in mice. Materials and Methods: Standard-sized wounds (1.5cm) were carried out in the face of 96 white albino mice. Half of them underwent LLLT treatment (360 J/cm 2) at 790-805 nm delivered immediately after wound pro

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 27 2022
Journal Name
Journal Of Lasers In Medical Sciences
Influence of Fiber Laser (1064 nm) on Shear Bond Strength of Titanium Abutment and Resin Cement
...Show More Authors

Introduction: The present study was performed to evaluate the influence of a 1064 nm fiber laser on shear bond strength (SBS) at the interface of titanium and resin cement. Methods: Forty titanium discs of 6 mm × 3 mm (diameter and thickness respectively) were categorized into four groups (n=10): control group without any surface treatment and three groups treated with a fiber laser with 81 ns pulse duration, 30 kHz frequency, 10000 mm/s scanning speed, 0.05 mm spot size, and different average power values (3, 5 and 7 W) depending on the tested group. Titanium disc characterization was performed by the scanning electron microscope (SEM) and surface roughness tester. Phase analysis was achieved using an X-ray diffractometer (XRD). F

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Dec 13 2005
Journal Name
Iraqi Journal Of Laser
Stimulation of Phagocytic Activity of Human Polymorphonuclear Leukocytes in Vitro Using 10 mW He-Ne Laser.
...Show More Authors

Stimulative effect of 10 mW He-Ne laser on the phagocytic activity of human polymorphonuclear leukocytes( PMNs) has been studied in vitro. Normal polymorphonuclear leucocytes were isolated from the human peripheral blood. A mixture of 0.25 ml of Hanks solution, 0.25 ml of serum, 0.25 ml of Candida albicans suspension and 0.25 ml of PMNs suspension was prepared. The samples of mixture of PMNs and Candida were subdivided in 1 ml ependrof tubes and irradiated to He-Ne laser for 1, 3, 5, 10 and 20 min. The diameter of the irradiated area was 0.8 cm. For calculation of Phagocytic index before and after irradiation, the samples were incubated (37°C) at 5, 15, 30, 60 min. The slides of samples were prepared and stained using Giemsa stain. The

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Effect of Low Energy Laser on the Healing of Tooth Extraction Wound: (Histological Study in Rat)
...Show More Authors

Aims: This study was done to investigate the effect of low energy laser therapy on bone healing at the extraction site. Materials and methods:(24) male albino rats were exposed to the extraction procedure of the maxillary first molar on the first day of a seven day experiment and these animals were divided into two main groups; the control group and the laser group. The laser experiment involved using (Ga-As infrared diode laser) from optodent by directing the probe over the extraction site. The control group consisted of 4 rats, and the laser group was subdivided into 5 subgroups of 4 rats each. The laser dose was as follows: B1: a single dose of 5 minutes immediately after extraction.,

... Show More
View Publication Preview PDF
Publication Date
Tue Feb 02 2016
Journal Name
International Journal Of Modern Physics B
Preparation of iron oxide nanoparticles by laser ablation in DMF under effect of external magnetic field
...Show More Authors

We have studied the effect of applying an external magnetic field on the characteristics of iron oxide (IO) nanoparticles (NPs) synthesized by pulsed laser ablation in dimethylformamide (DMF). The NPs synthesized with and without applying of magnetic field were characterized by Fourier transformation infrared spectroscopy (FT-IR), UV–Vis absorption, scanning electron microscope (SEM), atomic force microscope (AFM), and X-ray diffraction (XRD). SEM results confirmed that the particle size was decreased after applying magnetic field.

View Publication
Scopus (17)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Study of Nonlinear Refraction and Nonlinear Absorption Coefficients of Different CdS Film Thickness by diode laser
...Show More Authors

In the present work, different thicknesses of CdS film were prepared by chemical bath deposition. Z-Scan technique was used to study the nonlinear refractive index and nonlinear absorption coefficients. Linear optical testing were done such as transmission test, and thickness of films were done by the interference fringes (Michelson interferometer). Z-scan experiment was performed at 650nm using CW diode laser and at 532nm wavelength. The results show the effect of self-focusing and defocusing that corresponds with nonlinear refraction n2. The effect of two-photon absorption was also studied, which correspond to the nonlinear absorption coefficient B.

View Publication Preview PDF
Crossref