Preferred Language
Articles
/
joe-663
Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) device is used to obtain photos of a board including (23) ground control points on it, those observed from two stations and adjusted by using equations of the 3D adjusted triangulation networks by lengths and angles (hybrid routine). (10) GCPs and (13) checkpoints were used to compare the Root Mean Square Error (RMSE) of checkpoints that result from using laser scan cameras with (RMSE) of the same checkpoints that result from using digital photos (Nikon 5200D).

The result of (RMSE) comparison was ) in the X direction, ) in the Y direction and ) in the Z direction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of Factors That Contribute to Bladder Cancer
...Show More Authors

Abstract Objective: The study aimed to assess the factors contributes of patient with bladder cancer and to find out the relationship between the factors of bladder cancer with certain variable. Methodology: A descriptive study to assessment of factors that contribute to bladder cancer that was carried out Al-Karama teaching hospital, Al-Kendy teaching hospital, Specialty Surgery teaching hospital and Al-Yarmok teaching hospital for the period of November 2003 to August 2004. A purposive (non-probability) sample of (100) patients with bladder cancer. An assessment from was constructed for the purpose of the st

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
Heliyon
Environmental assessment of Al-Hammar Marsh, Southern Iraq
...Show More Authors

View Publication
Scopus (25)
Crossref (14)
Scopus Crossref
Publication Date
Wed Oct 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Design of Self-Assessment Scale to Accreditation Standards
...Show More Authors

The process of self-assessment plays a key role in achieving quality educational institutions (college, department or program academic particular), because the assessment process provides reviews of the effectiveness of the criteria used in the enterprise, especially in the field of teaching and learning, and is result self-assessment providing self-assessment report. The self- assessment can be performed at different levels (college, academic department, Master, Ph.D. program, or courses). The importance of the research focused on to provide a measure of self-assessment helps profile officials in the implementation of the assessment process are clear and precise and fast, and to provide them to measure the availability requireme

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ieee Access
Assessment of Delamination Under Insulation Using Ridge Waveguide
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
The Effects of Soft Laser on Some Blood Parameters of Patients with Breast Cancer
...Show More Authors

Background: Soft Laser has been advantageous in medical applications and is widely used in clinical practice. It is applied because it doesn’t cause the significant thermal effects or tissue hurt when irradiated. The blood response to low power laser radiation provides information about processes of laser radiation interaction with live creatures. Objective: The aim of the current work was to evaluate the laser-induced changes of in vitro erythrocyte sedimentation rate (ESR), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration (MCHC) in patients with breast cancer by irradiating a human blood sample using a green laser and comparing its effects before and after irradiation with the same power density (100mW/c

... Show More
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Pulse Profile Rule in Laser Heating of Opaque Targets in Air
...Show More Authors

A theoretical model is developed to determine time evolution of temperature at the surface of an opaque target placed in air for cases characterized by the formation of laser supported absorption waves (LSAW) plasmas. The model takes into account the power temporal variation throughout an incident laser pulse, (i.e. pulse shape, or simply: pulse profile).
Three proposed profiles are employed and results are compared with the square pulse approximation of a constant power.

View Publication Preview PDF
Crossref
Publication Date
Sun Apr 01 2007
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The Anticipated Hazards Due to Errors In Using Laser In Medicine & Recommendationms for the Safe Use Of Medical Laser Systems in Iraqi Hospitaals
...Show More Authors

• Causes of Laser Hazard
I - Inherent Hazards to Laser Beam Direct or reflected laser beams have consequential health effects range from minor skin burn to irreversible eye injuries. The hazards depend on the
power output and wavelength of the used laser and depend on the exposure time and MPE. ti & 2)

View Publication Preview PDF
Publication Date
Sun May 26 2019
Journal Name
Iraqi Journal Of Science
A Random Laser Production Using Fluorescein Dye Doped TiO2 Nanoparticles
...Show More Authors

A random laser has been produced using Fluorescein dye solution in water, with concentration of (8 10-5 M); doped with (0.001g) TiO2 Nanoparticles with the particle size of (15.7 nm). A blue diode laser of 450 nm wavelength has been used as an optical pumping source. The wavelength of the random laser was 523 nm and the intensity was 5.44 mW

View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Preparation of Vaccine against Diabetic Foot Pathogenic Bacteria Using Low Level Diode Laser
...Show More Authors

Background: Since the invention of laser in 1960, lasers have been developed and approved in many fields. Lasers can now be regarded as practical tools with unique properties that have been utilized effectively in several applications in fields of medical and biological sciences.Objectives: The aim of the current study was to preparation of vaccines (live attenuated and killed) by irradiation of the bacteria by the low level diode laser.Methods: six bacterial isolates were isolated from human samples of diabetic foot infections, which used for preparation of vaccines. The experiment was conducted on fifteen adult male rabbits; they were divided into three groups with 5 rabbits each. Blood samples were collected from the marginal ear vein

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
International Medical Journal
Surface analysis of the PEKK coating on the cp ti implant using laser technique
...Show More Authors

Objective: Evaluation of the poly ether keton keton polymer (PEKK) coating material on the commercial pure titanium disks (CP Ti) with or without laser surface structuring. Design: In vitro experimental study of PEKK polymer coated material on the CP Ti disks with or without laser surface structuring. Materials and methods: coating the surface of the commercial pure titanium (CP Ti) disks with PEKK polymer was performed via using frictional mode CO2 laser, then the samples disks analyzed by using FESEM. Results: the FESEM reveal good adherence and distribution of the PEKK coated material over the CP Ti substrate by using the frictional mode CO2 laser at 2 watt and 6 ms pulse duration. Conclusion: the frictional mode CO2 laser considered an

... Show More
Preview PDF
Scopus (6)
Scopus