Preferred Language
Articles
/
joe-663
Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) device is used to obtain photos of a board including (23) ground control points on it, those observed from two stations and adjusted by using equations of the 3D adjusted triangulation networks by lengths and angles (hybrid routine). (10) GCPs and (13) checkpoints were used to compare the Root Mean Square Error (RMSE) of checkpoints that result from using laser scan cameras with (RMSE) of the same checkpoints that result from using digital photos (Nikon 5200D).

The result of (RMSE) comparison was ) in the X direction, ) in the Y direction and ) in the Z direction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 10 2009
Journal Name
Iraqi Journal Of Laser
Immuno-hematological and biochemical changes in diabetic retinopathy patient`s blood after treatment by Nd-YAG laser
...Show More Authors

Diabetic retinopathy is one of most important complications of diabetes mellitus that can be treated by Nd:YAG laser. Laser is used in ophthalmic practice for photocoagulation and photodisruption. The purpose of this study is to evaluate changes in immunological ,hematological and biochemical values after treatment of diabetic retinopathy by laser. Blood samples from 10 patients suffering from diabetic retinopathy were taken before and after laser treatment to coagulate retina to prevent leakage and hemorraghe to avoid deterioration of vision.In group one (4 patients = 40%), blood tests were done one day after treatment. In group two (6 patients =60%) tests were done 7 days after treatment with laser. The study showed no clear changes in

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 30 2023
Journal Name
Optics Continuum
Ultrafast lithium disilicate veneer debonding time assisted by a CO<sub>2</sub> laser with temperature control
...Show More Authors

We report on using a CO2 (10.6 µm) laser to debond the lithium disilicate veneers. Sixty-four sound human premolar teeth and 64 veneer specimens were used in the study. The zigzag movement via CO2 laser handpiece along with an air-cooled jet to prevent temperature elevation above the necrosis temperature limit (5.5 C°) was applied. The optimal deboning irradiation time was super-fast, at about 5 seconds at 3 Watt CO2 laser power. It is 20 times less than any previously published work for veneers debonding. The enamel beneath the debonded veneers has been assessed by atomic force microscopy (AFM) and shear stress technique as criteria for the easiness of debonding. The

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Cavity Disinfection Using Er,Cr:YSGG Laser Induced Photoacoustic Streaming Technique: Rand kareem Jassim Hussein Ali Jawad*
...Show More Authors

Abstract:

Aim: The goal of this research was to study the influence of Er,Cr:YSGG laser at short pulse duration (60 µsec) on the number of streptococcus mutans bacteria in vitro.

Material and Methods:  twenty-eight extracted third molars free of caries, cracks, and other irregularities were used. For the testing of the materials, both the agar well technique and a tooth cavity model were employed. The agar wells of plates that had been inoculated with Streptococcus mutans previously were stuffed with the test materials, in order to conduct the tests. The zones of inhibition were assessed using millimeter measurements, after an incubation period of 48 hours .In order to a

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Using Low Level Laser (LLL for Treatment of Infected Mice with Carcinoma by Activating the Lymph Node Action without Drugs
...Show More Authors

Regional immune response with mammary gland carcinoma was
studied statistically. However, the prognostic value remains
conflicting. Thirty mice were used in this study which infected
were with mammary gland carcinoma. The tumor size of the animals
under study were measured before and after laser irradiation by using
a vernier and compared these results were with that of non irradiated
animals with laser (control group)
The aim of this study was to evaluate the effect of low level laser
therapy (LLLT) on increasing the response of immune system by
stimulating the lymph node action to decrease the cancer cell activity
and then decreasing the tumor size of an infected mice.
The results of the gross observati

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Laser Irradiation Effect on The Optical Properties of CoO<sub>2</sub>Thin Films deposited via Semi-Computerized Spraying System
...Show More Authors
Abstract<p>In this paper deals with the effect laser irradiation on the optical properties of cobalt oxide (CoO<sub>2</sub>) thin films and that was prepared using semi computerized spray pyrolysis technique. The films deposited on glass substrate using such as an ideal value concentration of (0.02)M with a total volume of 100 ml. With substrate temperature was (350 C), spray rate (15 ml/min).The XRD diffraction given polycrystalline nature with Crystal system trigonal (hexagonal axes). The obtained films were irradiated by continuous green laser (532.8 nm) with power 140 mW for different time periods is 10 min,20min and 30min. The result was that the optical properties of cobalt oxide thin films affe</p> ... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Preparation, Characterization & Biological activity for Some Iron(II) Complexes Containing Mixed Ligands (Benzilazine & Semicarbazone) & Study of Laser Effect on Them
...Show More Authors

The research included preparation of new iron(II) complexes with mixed ligands including benzilazine(BA) and semicarbazone ligands {benzilsemicarbazone- BSCH or benzilbis(semicarba-zone)- BBSCH2 or salicylaldehydesemicarbazone- SSCH2 or benzoinsemicarbazone- B'SCH2}.by classical and microwave methods. The resulted complexes have been characterized using chemical and physical methods. The study suggested that the above ligands form ionic complexes having formulae [Fe(SCHi)(BA)(Cl)m](Cl)2-m {where SCH, BSCH, BBSCH2, SSCH¬2 or B'SCH2 ligands; m=1 or 2}. Hexacoordinated mononuclear complexes have been investigated by this study and having octahedral geometries. The effect of laser ray type visible region have been studied on solid ligands and

... Show More
View Publication Preview PDF
Publication Date
Sun Oct 15 2023
Journal Name
Sumer 3
Treatment of shallow and deep white spot lesions with three different mouthwashes evaluated by laser fluorescence (an in vitro study)
...Show More Authors

This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks

... Show More
View Publication Preview PDF
Crossref (1)
Scopus Crossref
Publication Date
Tue Dec 13 2011
Journal Name
Iraqi Journal Of Laser
Intra Cellular Fluorescence for Monitoring The Physiological Changes and Biostimulation of Yeast Irradiated with Low Power 532nm CW Nd:YAG Laser
...Show More Authors

The purpose of this study is to investigate the biostimulation effect of 532 nm CW laser on the metabolism of Saccharomyces cerevisiae yeast. Cells were irradiated by 532 nm Nd:YAG laser using 0.153 W/cm2 power density at 30, 45, 60,180 and 300 seconds exposure times in their respective orders. Intrafluorescence parameters were measured by detection the autofluorescence intensity, proliferation rate and Imaging the fluorescent mitochondria using confocal laser scanning microscope. The results showed that the 30 and 45 second exposure times seem to have stimulated changes in the cells that led to increase proliferation, viability and mitochondrial activity. Autofluorescence of cells increased after 45 and 60 seconds exposure time. After 3

... Show More
View Publication Preview PDF