Accuracy Assessment of Stonex X-300 Laser Scanner Cameras
...Show More Authors

Assessment the actual accuracy of laboratory devices prior to first use is very important to know the capabilities of such devices and employ them in multiple domains. As the manual of the device provides information and values in laboratory conditions for the accuracy of these devices, thus the actual evaluation process is necessary.

In this paper, the accuracy of laser scanner (stonex X-300) cameras were evaluated, so that those cameras attached to the device and lead supporting role in it. This is particularly because the device manual did not contain sufficient information about those cameras.

To know the accuracy when using these cameras in close range photogrammetry, laser scanning (stonex X-300) device is used to obtain photos of a board including (23) ground control points on it, those observed from two stations and adjusted by using equations of the 3D adjusted triangulation networks by lengths and angles (hybrid routine). (10) GCPs and (13) checkpoints were used to compare the Root Mean Square Error (RMSE) of checkpoints that result from using laser scan cameras with (RMSE) of the same checkpoints that result from using digital photos (Nikon 5200D).

The result of (RMSE) comparison was ) in the X direction, ) in the Y direction and ) in the Z direction.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Journal Of Engineering
An Extensive Literature Review on Risk Assessment Models (Techniques and Methodology) for Construction Industry
...Show More Authors

This study looks into the many methods that are used in the risk assessment procedure that is used in the construction industry nowadays. As a result of the slow adoption of novel assessment methods, professionals frequently resort to strategies that have previously been validated as being successful. When it comes to risk assessment, having a precise analytical tool that uses the cost of risk as a measurement and draws on the knowledge of professionals could potentially assist bridge the gap between theory and practice. This step will examine relevant literature, sort articles according to their published year, and identify domains and qualities. Consequently, the most significant findings have been presented in a manne

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 09 2021
Journal Name
International Journal Of Environmental Science And Technology
Water quality index toward a reliable assessment for water supply uses: a novel approach
...Show More Authors

View Publication
Scopus (18)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Wed Dec 12 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment Pregnant Women’s Knowledge Regarding Syphilis at Primary Health care centers in Baghdad City
...Show More Authors

Objectives: To assess pregnant women’s knowledge regarding syphilisand to find out the relationship between women’s knowledge regarding syphilis infection and demographic and reproductive variables. Methodology: A descriptive analytical study of non probable (purposive sample) of 250 pregnant women during their different gestational ages for the period (October 2nd to April 25th 2013) by using questionnaire format consists of demographic variables and items of women's knowledge regarding syphilis who are visiting primary health care centers in Al-Kharkh and Al-Rrusafa in Baghdad city. The coefficient relia

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 10 2009
Journal Name
Iraqi Journal Of Laser
Immuno-hematological and biochemical changes in diabetic retinopathy patient`s blood after treatment by Nd-YAG laser
...Show More Authors

Diabetic retinopathy is one of most important complications of diabetes mellitus that can be treated by Nd:YAG laser. Laser is used in ophthalmic practice for photocoagulation and photodisruption. The purpose of this study is to evaluate changes in immunological ,hematological and biochemical values after treatment of diabetic retinopathy by laser. Blood samples from 10 patients suffering from diabetic retinopathy were taken before and after laser treatment to coagulate retina to prevent leakage and hemorraghe to avoid deterioration of vision.In group one (4 patients = 40%), blood tests were done one day after treatment. In group two (6 patients =60%) tests were done 7 days after treatment with laser. The study showed no clear changes in

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Cavity Disinfection Using Er,Cr:YSGG Laser Induced Photoacoustic Streaming Technique: Rand kareem Jassim Hussein Ali Jawad*
...Show More Authors

Abstract:

Aim: The goal of this research was to study the influence of Er,Cr:YSGG laser at short pulse duration (60 µsec) on the number of streptococcus mutans bacteria in vitro.

Material and Methods:  twenty-eight extracted third molars free of caries, cracks, and other irregularities were used. For the testing of the materials, both the agar well technique and a tooth cavity model were employed. The agar wells of plates that had been inoculated with Streptococcus mutans previously were stuffed with the test materials, in order to conduct the tests. The zones of inhibition were assessed using millimeter measurements, after an incubation period of 48 hours .In order to a

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2023
Journal Name
Optics Continuum
Ultrafast lithium disilicate veneer debonding time assisted by a CO<sub>2</sub> laser with temperature control
...Show More Authors

We report on using a CO2 (10.6 µm) laser to debond the lithium disilicate veneers. Sixty-four sound human premolar teeth and 64 veneer specimens were used in the study. The zigzag movement via CO2 laser handpiece along with an air-cooled jet to prevent temperature elevation above the necrosis temperature limit (5.5 C°) was applied. The optimal deboning irradiation time was super-fast, at about 5 seconds at 3 Watt CO2 laser power. It is 20 times less than any previously published work for veneers debonding. The enamel beneath the debonded veneers has been assessed by atomic force microscopy (AFM) and shear stress technique as criteria for the easiness of debonding. The

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Nov 07 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of mothers' practices toward children with steroid – sensitive nephrotic syndrome at pediatrics hospitals in Baghdad city
...Show More Authors

Objective(s): To assess mothers' practices toward children with steroid – sensitive Nephrotic Syndrome (SSNS) who
are visiting nephrology consultation units, and to find out the relationships between their practices and the
demographical data for mother and child.
Methodology: A descriptive study was carried out at nephrology consultation units of Baghdad pediatrics hospitals
(Child's Central Pediatric Teaching Hospital, Al-kadimiyia Teaching Hospital, and Welfare Teaching Hospital) started
from February 18th to the end of July 2009. A purposive sample of (80) mothers who company their children were
selected. The data were collected through a constructed questionnaire, with two parts; the first part is concerned with<

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Experimental Study for Assessment of Cutting Density Effect on Hole Cleaning Efficiency in Inclined and Horizontal Wells
...Show More Authors

The poor hole cleaning efficiency could causes many problems such as high torque, drag, poor hydraulics and pipe stuck. These inherent problems result in an avoidable high operation cost which this study tried to address.  In this study, the effect of cutting density on hole cleaning efficiency in deviated and horizontal wells was investigated. Experiments were conducted using 40 feet (12 m) long of flow loop made from iron and PVC. However, the test section was made from PVC with (5.1m) long and (4” ID) for outer pipe and (2” OD) inner pipe. The cutting transport ratio (CTR) was determined from weight measurements for each test. Cutting Transport Ratio has been investigated for effects of the following parameters; flow rate, cu

... Show More
View Publication Preview PDF
Crossref (5)
Crossref