Preferred Language
Articles
/
joe-662
Bond Stresses between Reinforcing Bar and Reactive Powder Concrete
...Show More Authors

A good performance of reinforced concrete structures is ensured by the bond between steel and concrete, which makes the materials work together, forming a part of solidarity. The behavior of the bond between the reinforcing bar and the surrounding concrete is significant to evaluate the cracking control in serviceability limit state and load capacity in the ultimate limit state. In this investigation, the bond stresses between reinforcing bar and reactive powder concrete (RPC) was considered to compare it with that of normal strength concrete (NSC). The push-out test with short embedment length is considered in this study to evaluate the bond strength, bond stress-slip relationship, and bond stress-crack width relationship for reactive powder concrete members. The compressive strength of concrete, the nominal diameter of reinforcement, concrete cover, and amount of steel fibers and embedded length of reinforcement were considered as variables in this study.

The test results show that the ultimate bond stress increased with increasing of the compressive strength of concrete, decreasing the nominal diameter of the reinforcing bar, increasing the concrete cover and increasing steel fiber content. In a bond stress-slip relationship, the NSC specimen shows a very short softening zone after reaching the peak point in comparisons with RPC specimen. In RPC, bond stress-slip relationship shows stiffer behavior when the steel fiber content was increased. RPC shows stepper softening zone due to the presence of steel fiber, and the absence of steel fiber cause push-out failure without descending part after peak point. Using NSC instead of RPC in anchorage between reinforcement and concrete, decrease the crack width produced due to radial tensile stresses through the push-out of reinforcing bar. In RPC, the absence of steel fiber, decrease the nominal diameter of the reinforcing bar, increase the concrete cover, decrease the embedded length of reinforcing bar cause push-out failure and vice versa cause splitting failure.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 20 2021
Journal Name
Earth And Environmental Science
Time Dependent Behavior of Engineered Cementitious Composite Concrete Produced from Portland Limestone Cement
...Show More Authors

Conventional concretes are nearly unbendable, and just 0.1 percent of strain potential makes them incredibly brittle and stiff. This absence of bendability is a significant cause of strain failure and has been a guiding force in the production of an elegant substance, bendable concrete, also known as engineered cement composites, abbreviated as ECC. This type of concrete is capable of displaying dramatically increased flexibility. ECC is reinforced with micromechanical polymer fibers. ECC usually uses a 2 percent volume of small, disconnected fibers. Thus, bendable concrete deforms but without breaking any further than conventional concrete. This research aims to involve this type of concrete, bendable concrete, that will give solut

... Show More
Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Engineering
The Effect of Cement and Admixture Types on the Resistance of High Performance Concrete to Internal Sulphate Attack
...Show More Authors

This work is concerned with the study of the effect of cement types, particularly OPC and SRPC, which are the main cement types manufactured in Iraq. In addition, study the effect of mineral admixtures, which are HRM and SF on the resistance of high performance concrete (HPC) to internal sulphate attack. The HRM is used at (10%) and SF is used at (8 and 10)% as a partial replacement by weight of cement for both types. The percentages of sulphate investigated are (1,2 and 3)% by adding natural gypsum as a partial replacement by weight of fine aggregate. The tests carried out in this work are: compressive strength, flexural strength, ultrasonic pulse velocity, and density at the age of 7, 28, 90 and 120 days.

The r

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
Influence of Internal Sulfate Attack on Some Properties of High Strength Concrete
...Show More Authors

One of the most important problems that faces the concrete industry in Iraq is the deterioration due to internal sulfate attack , since it reduces the compressive strength and increases the expansion of concrete. Consequently, the concrete structure may be damage .The effects of total and total effective sulfate contents on high strength concrete (HSC) have been studied in the present study. The research studied the effect of sulfate content in cement , sand and gravel , as well as comparing the total sulfate content with the total effective SO3 content. Materials used were divided into two groups of SO3 in cement ,three groups of SO3 in sand ,and two groups of SO3 in gravel. The results show that considering the total effective sulfate con

... Show More
Preview PDF
Publication Date
Sat Aug 01 2015
Journal Name
Journal Of Engineering
Influence of Internal Sulfate Attack on Some Properties of High Strength Concrete
...Show More Authors

One of the most important problems that faces the concrete industry in Iraq is the deterioration due to internal sulfate attack , since it  reduces the compressive strength and increases the expansion of concrete. Consequently, the concrete structure may be damage .The effects of total and total effective sulfate contents on high strength concrete (HSC) have been studied in the present study.

The research studied the effect of sulfate content in cement , sand and gravel , as well as comparing  the total sulfate content with the total effective SO3 content. Materials used were divided into two groups of SO3 in cement ,three groups of SO3 in sand ,and two groups of SO

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 02 2015
Journal Name
Desalination And Water Treatment
Effect of pH on the performance of olive pips reactive barrier through the migration of copper-contaminated groundwater
...Show More Authors

Scopus (14)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Wed Dec 28 2016
Journal Name
Environmental Technology
Remediation of groundwater contaminated with the lead–phenol binary system by granular dead anaerobic sludge-permeable reactive barrier
...Show More Authors

Scopus (18)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Desalination And Water Treatment
Numerical modeling of performance of olive seeds as permeable reactive barrier for containment of copper from contaminated groundwater
...Show More Authors

Scopus (17)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Physica B: Condensed Matter
Effect of gas mixing ratio on structural characteristics of titanium dioxide nanostructures synthesized by DC reactive magnetron sputtering
...Show More Authors

View Publication
Scopus (26)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Mon Sep 07 2020
Journal Name
Environmental Science And Pollution Research
The biosorption of reactive red dye onto orange peel waste: a study on the isotherm and kinetic processes and sensitivity analysis using the artificial neural network approach
...Show More Authors

View Publication
Scopus (26)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Mon Jun 27 2022
Journal Name
Sustainability
Thermal Properties of Hydrated Lime-Modified Asphalt Concrete and Modelling Evaluation for Their Effect on the Constructed Pavements in Service
...Show More Authors

Flexible pavements are subjected to three main distress types: fatigue crack, thermal crack, and permanent deformation. Under severe climate conditions, thermal cracking particularly contributes largely to a considerable scale of premature deterioration of pavement infrastructure worldwide. This challenge is especially relevant for Europe, as weather conditions vary significantly throughout the year. Hydrated lime (HL) has been recognized as an effective additive to improve the mechanical properties of asphalt concrete for pavement applications. Previous research has found that a replacement of conventional limestone dust filler using hydrated lime at 2.5% of the total weight of aggregates generated an optimum improvement in the mec

... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Clarivate Crossref