Preferred Language
Articles
/
joe-662
Bond Stresses between Reinforcing Bar and Reactive Powder Concrete
...Show More Authors

A good performance of reinforced concrete structures is ensured by the bond between steel and concrete, which makes the materials work together, forming a part of solidarity. The behavior of the bond between the reinforcing bar and the surrounding concrete is significant to evaluate the cracking control in serviceability limit state and load capacity in the ultimate limit state. In this investigation, the bond stresses between reinforcing bar and reactive powder concrete (RPC) was considered to compare it with that of normal strength concrete (NSC). The push-out test with short embedment length is considered in this study to evaluate the bond strength, bond stress-slip relationship, and bond stress-crack width relationship for reactive powder concrete members. The compressive strength of concrete, the nominal diameter of reinforcement, concrete cover, and amount of steel fibers and embedded length of reinforcement were considered as variables in this study.

The test results show that the ultimate bond stress increased with increasing of the compressive strength of concrete, decreasing the nominal diameter of the reinforcing bar, increasing the concrete cover and increasing steel fiber content. In a bond stress-slip relationship, the NSC specimen shows a very short softening zone after reaching the peak point in comparisons with RPC specimen. In RPC, bond stress-slip relationship shows stiffer behavior when the steel fiber content was increased. RPC shows stepper softening zone due to the presence of steel fiber, and the absence of steel fiber cause push-out failure without descending part after peak point. Using NSC instead of RPC in anchorage between reinforcement and concrete, decrease the crack width produced due to radial tensile stresses through the push-out of reinforcing bar. In RPC, the absence of steel fiber, decrease the nominal diameter of the reinforcing bar, increase the concrete cover, decrease the embedded length of reinforcing bar cause push-out failure and vice versa cause splitting failure.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jan 15 2002
Journal Name
Abhath Al- Yarmouk [basic Sciences And Engineering]
Computer Program for Predicting Ultimate Strength of Structural Concrete Sections of General Shape
...Show More Authors

Publication Date
Fri Feb 26 2021
Journal Name
Life-cycle Civil Engineering: Innovation, Theory And Practice
Shear performance of a novel demountable connector for reusable steel-concrete composite structures
...Show More Authors

A novel demountable shear connector is proposed to link a concrete slab to steel sections in a way that resulting steel-concrete composite floor is demountable, i.e. it can be easily dismantled at the end of its service life. The proposed connectors consist of two parts: the first part is a hollow steel tube with internal threads at its lower end. The second part is a compatible partially threaded bolted stud. After linking the stud to the steel section, the hollow steel tube can be fastened over the threaded stud, which create a complete demountable shear connector. The connector is suitable for use in both composite bridges and buildings, and using cast in-situ slabs, precast solid slabs, or hollow-core precast slabs. A series of push-off

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Materials Today: Proceedings
Solving high sulfate content of sand used in concrete by magnetic water process
...Show More Authors

View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri May 01 2020
Journal Name
Civil Engineering Journal
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
...Show More Authors

This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,

... Show More
Crossref (1)
Crossref
Publication Date
Fri May 01 2020
Journal Name
Civil Engineering Journal
Post-Fire Behavior of Post-Tensioned Segmental Concrete Beams under Monotonic Static Loading
...Show More Authors

This paper presents a study to investigate the behavior of post-tensioned segmental concrete beams that exposed to high-temperature. The experimental program included fabricating and testing twelve simply supported beams that divided into three groups depending on the number of precasting concrete segments. All specimens were prepared with an identical length of 3150 mm and differed in the number of the incorporated segments of the beam (9, 7, or 5 segments). To simulate the genuine fire disasters, nine out of twelve beams were exposed to a high-temperature flame for one hour. Based on the standard fire curve (ASTM – E119), the temperatures of 300◦C (572◦F), 500◦C (932◦F), and 700◦C (1292◦F) were adopted. Consequently,

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Sep 03 2021
Journal Name
Buildings
Structural Efficiency of Hollow Reinforced Concrete Beams Subjected to Partial Uniformly Distributed Loading
...Show More Authors

Reinforced concrete (RC) beams containing a longitudinal cavity have become an innovative development and advantage for economic purposes of light-weight members without largely affecting their resistance against the applied loads. This type of openings can also be used for maintenance purposes and usage space of communication lines, pipelines, etc. RC beams are primarily loaded in the plane of the members, which are two-dimensional in a plane stress state and the dominant structural behaviours include bending, shear, or combination of both. In the present study, six numerical models of RC beams with and without openings were simulated by using commercial finite element software ANSYS to evaluate the structural behaviours of those b

... Show More
View Publication
Scopus (17)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental Study on the Behaviours of Post-tensioned Concrete Members with Unbonded Tendons
...Show More Authors
Abstract<p>This paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength, <italic>f<sub>c</sub> </italic>′; jacking stress, <italic>f<sub>j</sub> </italic>; and the prestressing index, ω. Increasing the concrete compressive strength from 35 MPa to 60 MPa was seen to lead to an increase in load-carrying capacity by about 10%. The load capacity was also affected, though to a lesser extent, by the jacking stress. The failure lo</p> ... Show More
View Publication
Publication Date
Tue Nov 15 2022
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
A-mechanical properties of engineered cementitious composite concrete produced from Portland limestone cement
...Show More Authors

Conventional concretes are almost unbending, and even a small amount of strain potential leaves them brittle. This lack of bendability is a major source of strain loss, and it has been the main goal behind the development of bendable concrete, often known with engineered ce ment composites, or ECC. This form of concrete has a lot more flexibility than regular concrete. Micromechanical polymer fibers are used to strengthen ECC. In most cases, ECC uses a 2% amount of thin, separated fibers. As a result, bendable concrete deforms but unlike traditional concrete, it does not crack. This study aims to include this kind of concrete, bendable concrete, which can be used to solve concrete problems. Karasta (CK) and Tasluja (CT) Portland Lime

... Show More
Publication Date
Sun Aug 01 2021
Journal Name
Journal Of Engineering
Reuse of Glass waste as a partial replacement to fine aggregates in concrete
...Show More Authors

As human societies grow, the problem of waste management becomes one of the pressing issues that need to be addressed. Recycling and reuse of waste are effective waste management measures that prevent pollution and conserve natural resources. In this study, the possibility of using glass waste as an alternative was used as a partial weight substitute for fine aggregates with replacement ratios of 10, 20, 30, and 40% by the weight, and formed into test models (15 cm * 15 cm ) cube and (15 cm * 30 cm) cylinder, then matured and tested their strength compression and tensile strength at the age of 7 and 28 days and compared with a reference or conventional concrete with a mixing ratio (1: 1.5: 3) as well as testing its worka

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Jun 04 2025
Journal Name
Engineering, Technology &amp; Applied Science Research
Investigating Fiber Reinforcement Effects on the Performance of Concrete Pavements under Repeated Load
...Show More Authors

Concrete pavements are essential to modern infrastructure, but their low tensile and flexural strengths can cause cracking and shrinkage. This study evaluates fiber reinforcement with steel and carbon fibers in various combinations to improve rigid pavement performance. Six concrete mixes were tested: a control mix with no fiber, a mix with 1% steel fiber (SF1%), a mix with 1% carbon fiber (CF1%), and three hybrid mixes with 1% fiber content: 0.75% steel /0.25% carbon fiber (SF0.75CF0.25), 0.25% steel /0.75% carbon fiber (SF0.25CF0.75), and 0.5% steel /0.5% carbon fiber ((SF0.5CF0.5). Laboratory experiments including compressive, flexural, and splitting tensile strength tests were conducted at 7, 28, and 90 days, while Finite Element Analys

... Show More
View Publication
Scopus Crossref