Preferred Language
Articles
/
joe-650
Evaluation The Performance Geodetic of the Receivers Using Static Positioning Technique
...Show More Authors

Global Navigation Satellite System (GNSS) is considered to be one of the most crucial tools for different applications, i.e. transportation, geographic information systems, mobile satellite communications, and others. Without a doubt, the GNSS has been widely employed for different scientific applications, such as land surveying, mapping, and precise monitoring for huge structures, etc. Thus, an intense competitive has appeared between companies which produce geodetic GNSS hardware devices to meet all the requirements of GNSS communities. This study aims to assess the performance of different GNSS receivers to provide reliable positions. In this study, three different receivers, which are produced by different manufacturers, were fixed to form a triangle. Simultaneous observations were made in static mode (2.5 to 3 hours). This observation technique was carried out three times by changing the location of receivers in each time to ensure that three receivers observed each station three times. To evaluate the performance of each receiver, OPUS web-based processing software and TOPCON TOOLS were used to process the raw GNSS observations. The distances between adjacent stations were computed for each observation and compared to standard distances, which were measured using a total station. Furthermore, the internal angles were also computed and compared to those measured by Total Stations. The results showed that some calculated distances are closer to the corresponding distances measured by the total station. This indicates that the receivers involved in the composition of these distances are the most accurate.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis and Preliminary Pharmacological Evaluation of New Analogues of Diclofenac as Potential Anti-inflammatory Agents
...Show More Authors

         A group of amine derivatives [4-aminobenzenesulfonamide derivatives, 2-aminopyridine and 2-aminothiazole] incorporated to α-carbon of diclofenac a well known non-steroidal anti-inflammatory drug (NSAID) to increase bulkiness were designed and synthesized for evaluation as  a potential anti-inflammatory agents with expected COX-2 selectivity. In vivo acute anti-inflammatory activity of the selected final compounds (9, 12 and 13) was evaluated in rats using egg-white induced edema model of inflammation in a dose equivalent to (3 mg/Kg) of diclofenac sodium. All tested compounds  produced a significant reduction  in paw edema with respect to the effect of propylene glycol 50

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Nov 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of corrosion behavior of bioceramics coated commercially pure titanium and Ti-6Al-4V alloy
...Show More Authors

Background: This study report the corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy samples without coating and with hydroxyapatite, partial stabilized zirconia and mixture of partial stabilized zirconia and hydroxyapatite coating and comparison between them through electrochemical polarization tests in 37 0 C Hank's solution. Materials and methods: Electrophoretic deposition technique (EPD) was used to achieve the coating from each one of three types of the coating materials (HAP, PSZ and mixture of 50% HAP and 50%PSZ) on Cp Ti and Ti-6Al-4V alloy samples. The electrochemical corrosion test was performed when samples were exposed to Hank's solution prepared in the laboratory and the polarization potential, corrosion rate

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
EVALUATION OF ELECTRONIC GOVERNMENT SECURITY ISSUES APPLIED TO COMPUTER CENTER OF BAGHDAD UNIVERSITY (CASE STUDY)
...Show More Authors

Information security contributes directly to increase the level of trust between the government’s departments by providing an assurance of confidentiality, integrity, and availability of sensitive governmental information. Many threats that are caused mainly by malicious acts can shutdown the egovernment services. Therefore the governments are urged to implement security in e-government projects.
Some modifications were proposed to the security assessment multi-layer model (Sabri model) to be more comprehensive model and more convenient for the Iraqi government. The proposed model can be used as a tool to assess the level of security readiness of government departments, a checklist for the required security measures and as a commo

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 08 2025
Journal Name
Journal Of Baghdad College Of Dentistry
In-Vitro evaluation of load-deflection characteristics and force levels of nickel titanium orthodontic archwires
...Show More Authors

Background: Nickel-titanium (NiTi) archwires have become increasingly popular because of their ability to release constant light forces, which are especially useful during initial alignment and leveling phase. The aim of the present study was to investigate and compare the load–deflection characteristics of four commercially available NiTi archwires. Materials and methods: 200 NiTi 0.014, 0.016, 0.018, 0.016x0.022 and 0.019x0.025-inch nickel–titanium archwires from four different manufacturers (3M, Ortho Technology, Jiscop and Astar) were tested. The load-deflection properties of these archwires were evaluated by a full arch bending test in both palatal and gingival directionsat 37°C temperature using a universal material t

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
Agricultural Engineering
Evaluation of Flat Fan Nozzles Operating Parameters Under Conditions of Accelerated Boundary and Destructive Wear
...Show More Authors
Abstract<p>Two tests were carried out to measure the standard flat fan nozzles wear during a specific period of an accelerated wear procedure. The first test aimed at getting 10% increase in the flow rate compared to the nominal flow rate, which is the threshold to replace the nozzles according to the nozzles testing standards. The second test was to wear the nozzles intensively (100 hours of accelerated wear), which represents the use of nozzles beyond the allowed threshold. The results showed that the flow rate reached 1.31 l·min<sup>−1</sup> (equal to 10% increase) for the tested nozzles after 35 hours of the wear test. For the second test, the 10% increase of the flow rate was r</p> ... Show More
Crossref (1)
Crossref
Publication Date
Wed Jul 26 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and Evaluation of Fast Dissolving Tablets of Taste-Masked Ondansetron Hydrochloride by Solid Dispersion
...Show More Authors

Ondansetron hydrochloride (ONH) is a very bitter, potent antiemetic drug used for the treatment and/or prophylaxis of chemotherapy or radiotherapy or postoperative induced emesis. The objective of this study is to formulate and evaluate of taste masked fast dissolving tablet (FDTs) of ONH to increase patient compliance.

 ONH taste masked granules were prepared by solid dispersion technique using Eudragit E100 polymer as an inert carrier. Solvent evaporation and fusion melting methods were used for such preparation.

Completely taste masking with zero release of drug in phosphate buffer pH 6.8was obtained from granules prepared by solvent evaporation method using drug: polymer ratio of 1:2, from which four formulas pas

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Thu May 31 2012
Journal Name
Journal Of Baghdad College Dentistry
An evaluation of water absorption of Giomer in comparison to other resin-based restorative materials
...Show More Authors

Background: Polymeric composites have been widely used as dental restorative materials. A fundamental knowledge and understanding of the behavior of these materials in the oral cavity is essential to improve their properties and performance. The goal of this study was to measure water sorption of four composite resins containing different filler and resin matrix contents. Materials and method: Resin composite specimens giomer (Beautifil II) Filtek™ P90, Filtek™ Z350 XT, and Tetric N Ceram were prepared in a cylindrical mould of 3mm thickness and 6mm diameter (n=10) and light cured . All specimens placed in silica-gel desiccators at 37˚C for seven days, a constant weight was obtained. All samples were immersed in deionized distill

... Show More
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Histological Evaluation of Effect of beta-Tricalcium Phosphate on Bone healing in Alloxan-Induced diabetes
...Show More Authors

Background: Improved glucose level control with insulin injections have allowed for the diabetic population to live longer and healthier lives. Unfortunately diabetes remains a worldwide epidemic disease with multiple health implications. Specifically, its effects upon fracture healing are compromised in diabetics with as high as 87% recovery delay relative to “healthy” counterparts. Current medical treatments for bone injuries have been largely focused on replacing the lost bone with allogenic or autogenous bone grafts, beta-tricalcium phosphate (β -TCP), a ceramic alloplast, has interconnected system of micropores, has been widely used as a biologically safe osteoconductive bone substitute. The aim of this study was histol

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Malaysian Journal Of Biochemistry & Molecular Biology
Evaluation influence of extract of Terfezia claveryi desert truffle, pezizaceae, against Streptococcus pneumoniae, in vivo
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sat Jan 25 2020
Journal Name
Indian Journal Of Forensic Medicine &amp; Toxicology
A Comparative Evaluation of Gutta-Percha and Sealer Removal of Rotary Niti File Retreatment Systems
...Show More Authors

Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area,

... Show More
View Publication Preview PDF
Crossref