This study was carried out to investigate the effects of magnetized water on accumulated infiltration depth. A test rig was designed and constructed for this purpose was installed at the water tests laboratory of the Department of Water Resources Engineering at the University of aghdad. The investigation was carried out by using two types of soil, different flow velocities throughout magnetizing device and different configuration of magnets over and under the water passage of the magnetizing device. The soils that were used in the experiments are clayey and sandy soils. Six different flow velocities throughout magnetizing device ranged between 0.29 to 1.19 cm/s and ten configurations of arranging the magnets over and under the water passage of the magnetizing device were used. The magnates are sintered neodymium-iron-boron type. Tests results obtained with magnetized water were compared with those of untreated water. Results showed that magnetizing water increases the accumulated infiltration depth for the two types of soil. The highest increase in the accumulated infiltration depth is achieved under low flow velocity throughout the magnetizing device and with ten magnets. This highest increase for the clayey and sandy soils was 98.2% and 34.2%, respectively.
Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and study the characterization of a relative humidity sensor based on a polymer-infiltrated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) reflection mode. The fabrication of the sensor only involves splicing and cleaving Photonic Crystal Fiber (PCF) with Single Mode Fiber (SMF). A stub of (LMA-10) PCF spliced to SMF (Corning-28). In the splice regions. The PCFI sensor operation based on the adsorption and desorption of water vapour at the silica-air interface within the PCF. The sensor shows a high sensitivity to RH variations from (27% RH - 95% RH), with a change in its reflected powe
... Show MoreThe plasma source can restrict the motion of charges that are localizing in the non equilibrium distribution of charge energy and reducing the electrons transport across magnetic field . The electrons & ions motion are controlled by ambipolar electric field and charge–atom collision . the source density for a given electron temperature and a given ion are considered to evaluate the diffusion coefficient . the ambipolar diffusion coefficient and the cross field diffusion coefficient for charge transfer are calculated through magnetized plasma in a uniform magnetic field , and an approximation ambipolar diffusion coefficient is evaluated. The result, showes how the diffusion process is gradually im
... Show MoreObjective: This experiment was conducted to study the effects of ionized water on certain egg quality traits and the levels of proteins and enzymes in the blood of the Japanese quail Coturnix japonica . Materials and Methods: One hundred 42-day-old quail were randomly distributed among five treatment groups with four replicates for each group. The following treatments were used: T1 (control): The birds were provided normal water, T2: The birds were provided alkaline water (pH = 8), T3: The birds were provided alkaline water (pH = 9), T4: The birds were provided acidic water (pH = 6) and T5: The birds were provided acidic water (pH = 5). A Complete Randomized Design (CRD) was used to investigate the effects of the studied treatments on diffe
... Show MoreGypseous soils are considered one of the most problematic soils. The skirted foundation is an alternative technology that works to improve the bearing capacity and reduce settlement. This paper investigates the use of square skirted foundations resting on gypseous soil subjected to concentric and eccentric vertical load with eccentricity values of 4, 8, and 17 mm in 16 experimental model tests. To obtain the results by using this type of foundation, a small-scale physical model was designed to obtain the load–settlement behavior of the square skirted foundation; the dimension of the square footing is 100 mm × 100 mm with 1 mm thickness, the skirt depth (
A number of glow discharge experiments has been carried out in a relatively large-volume metallic vacuum chamber containing argon at low pressure and immersed in an inhomogeneous magnetic field generated by a solenoidal coil capable of delivering 2100G. Two Paschen curves demonstrating the dependence of the discharge voltage on sparking parameter Pd and magnetic field strength B were deduced. A graphical correlation showing the behaviour of the voltage difference from the two curves on the ratio B/Pd was constructed. Investigations showed a reduction in the nominal impedance of the discharge device of nearly 20% when B reaches a value of 525G. Plasma confinement regions were found around the internal surface of the chamber at the entranc
... Show MoreDynamic loads highly influence soil properties and may cause real damage to structures and buildings. This article reports the experimental results from 24 tests to study the settlement of flexible and rigid raft foundation with different embedment depth rested on dense sandy soil. A small scale building model of dimension 200*200 mm and 320 mm in height was performed with reinforced concrete raft foundation of 10 mm thickness for flexible raft and 23 mm for rigid raft, The shaking table technique was used to simulate the seismic effect, the shaker was sat to give three different excitation frequencies 1,2,and3 Hz and displacement amplitude equal to 13 mm, the foundation was placed at
Objectives: The purpose of this in vitro study was to compare the effect of adding poloxamer surfactant to irrigant solutions on the penetration de..