Preferred Language
Articles
/
joe-646
Fabrication of Copper-Graphite MMCs Using Powder Metallurgy Technique
...Show More Authors

Copper, and its, alloys and composites (being the matrix), are broadly used in the electronic as well as bearing materials due to the excellent thermal and electrical conductivities it has.

In this study, powder metallurgy technique was used for the production of copper graphite composite with three volume perc ent of graphite.  Processing parameters selected is (900) °C sintering temperature and (90) minutes holding time for samples that were heated in an inert atmosphere (argon gas). Wear test results showed a pronounced improvement in wear resistance as the percent of graphite increased which acts as solid lubricant (where wear rate was decreased by about 88% as compared with pure Cu). Microhardness and compressive strength increased (about 8% and 16%, for each of them) and reached to the maximum values at 1% graphite percentage as compared with pure Cu, then it decreased after that critical graphite concentration. Microstructure test indicated that the dark region in the copper matrix was increased as the percent of graphite increased and the reinforcement particles were homogeneously distributed which means that the powder metallurgy technique is suitable for such task.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jun 01 2020
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Different Hand and Finger Grip Patterns using Surface Electromyography and Hand Dynamometry
...Show More Authors

Recording an Electromyogram (EMG) signal is essential for diagnostic procedures like muscle health assessment and motor neurons control. The EMG signals have been used as a source of control for powered prosthetics to support people to accomplish their activities of daily living (ADLs). This work deals with studying different types of hand grips and finding their relationship with EMG activity. Five subjects carried out four functional movements (fine pinch, tripod grip and grip with the middle and thumb finger, as well as the power grip). Hand dynamometer has been used to record the EMG activity from three muscles namely; Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), and Abductor Pollicis Brevis (ABP) with different le

... Show More
View Publication
Crossref (7)
Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Study photometric properties of spiral galaxy NGC 4448 using CCD camera with multiband filters
...Show More Authors

The goal of our study is to perform detailed multiband surface photometry of the spiral galaxy NGC 4448 and its brightest star-forming regions. The structure and composition of the stellar population in the surface brightness galaxy NGC 4448 was studied using BVR CCD photometry. The observations were obtained on the 1.88 m optical telescope of Kottamia Astronomical Observatory (KAO), Egypt. A two-dimensional decomposition of the galaxy bulge and disk components is carried out. A powerful star forming region is observed near the galactic center. Based on the positions of the various components of the galaxy in two color diagrams. From the observations, the surface brightness profiles, Ellipticity profiles, position angle profiles and colo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 01 2011
Journal Name
Journal Of The Saudi Society Of Dermatology & Dermatologic Surgery
Treatment of pityriasis versicolor using 1% diclofenac gel and clotrimazole cream (comparative therapeutic study)
...Show More Authors

KE Sharquie, HM Al-Hamamy, AA Noaimi, IA Al-Shawi, Journal of the Saudi Society of Dermatology & Dermatologic Surgery, 2011 - Cited by 9

View Publication
Publication Date
Mon Feb 01 2021
Journal Name
Journal Of Engineering
Investigations on the Impact of Using Elliptic Groynes on the Flow in Open Channels
...Show More Authors

This paper presents a numerical simulation of the flow around elliptic groynes by using CFD ‎software. The flow was simulated in a flume with 4m long, 0.4m wide, ‎and 0.175m ‎high ‎‎with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow ‎‎inlet with a ‎constant the Groyne height of 10cm and a 1cm thickness, and the ‎width of Groynes equals ‎7cm‎. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of ‎0.0057‎m3/sec. The CFD ‎model showed a good ability to simulate the flow ‎around ‎Groynes with ‎ good accuracy. The results of ‎CFD software showed that when using double elliptic Groy

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Compound fractures of the hand metacarpals and phalanges treated by using mini-external fixator
...Show More Authors

Background: A review of articles of method in treating compound phalangeal fractures by using mini-external fixator, elaborating the anatomy, mechanics, modalities of treatment, and complications of these types of fractures. Also, it compares between different studies regarding the functional results and final outcome. External fixation of phalangeal fractures is a good method for osteo synthesis in certain situations. The simplicity of the surgical procedure and the minimal disruption of the normal bone architecture also make it appealing.Objectives: Evaluating the functional results of the use of mini-external fixator for the treatment of compound fractures of phalangeal bones of the hand.Method: Our study consists of 15 patients, 12 w

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Reservoir Hydraulic Flow Units and Permeability Estimation Using Flow Zone Indicator Method
...Show More Authors

   Reservoir characterization plays a crucial role in comprehending the distribution of formation properties and fluids within heterogeneous reservoirs. This knowledge is instrumental in constructing an accurate three-dimensional model of the reservoir, facilitating predictions regarding porosity, permeability, and fluid flow distribution. Among the various methods employed for reservoir characterization, the hydraulic flow unit stands out as a widely adopted approach. By effectively subdividing the reservoir into distinct zones, each characterized by unique petrophysical and geological properties, hydraulic flow units enable comprehensive reservoir analysis. The concept of the flow unit is closely tied to the flow zone indicator, a cr

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Sep 02 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Desulphurization of Simulated Oil Using SAPO-11 with CNT's as Adsorbent: A Kinetic Study
...Show More Authors

In this study, sulfur was removed from imitation oil using oxidative desulfurization process. Silicoaluminophosphate (SAPO-11) was prepared using the hydrothermal method with a concentration of carbon nanotubes (CNT) of 0% and 7.5% at 190 °C crystallization temperature. The final molar composition of the as-prepared SAPO-11 was Al2O3: 0.93P2O5: 0.414SiO2. 4% MO/SAPO-11 was prepared using impregnation methods. The produced SAPO-11 was described using X-ray diffraction (XRD) and Brunauer-Emmet-Teller (N2 adsorption–desorption isotherms). It was found that the addition of CNT increased the crystallinity of SAPO-11. The results showed that the surface area of SAPO-11 containing 7.5% CNT was 179.54 m2/g, and the pore volume was 0.31

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Optimal Dimensions of Small Hydraulic Structure Cutoffs Using Coupled Genetic Algorithm and ANN Model
...Show More Authors

A genetic algorithm model coupled with artificial neural network model was developed to find the optimal values of upstream, downstream cutoff lengths, length of floor and length of downstream protection required for a hydraulic structure. These were obtained for a given maximum difference head, depth of impervious layer and degree of anisotropy. The objective function to be minimized was the cost function with relative cost coefficients for the different dimensions obtained. Constraints used were those that satisfy a factor of safety of 2 against uplift pressure failure and 3 against piping failure.
Different cases reaching 1200 were modeled and analyzed using geo-studio modeling, with different values of input variables. The soil wa

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Mon Mar 07 2022
Journal Name
Journal Of Educational And Psychological Researches
Appropriateness of the Multi-Attitude Suicide Tendency (MAST) scale using a saudi adolescent sample
...Show More Authors

The current study aimed to standardize the multi-position suicidal tendency scale MAST in the Saudi environment as well as to assess suicidal tendencies in adolescents. Moreover, the study aimed to test the psychometric characteristics of the scale among a sample of (490) high school and undergraduate students, in the adolescence who ranging in age from (16-21) years. The scale demonstrated satisfactory internal consistency in terms of validity and reliability tests. as the results showed of exploratory factor analysis to the four dimensions of suicidal tendencies loading on two factors that accommodate 74.60% of the overall variance of the scale (1) the attitude toward life,  and absorbs 43, 20% of the total variance of the scale,

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
International Journal Of Hydrogen Energy
Improvement of photofermentative biohydrogen production using pre-treated brewery wastewater with banana peels waste
...Show More Authors

View Publication
Scopus (72)
Crossref (67)
Scopus Clarivate Crossref