Preferred Language
Articles
/
joe-633
Zeta Potential, Effective Membrane Charge and Donnan Potential for TiO2 NF Ceramic Membrane
...Show More Authors

Nanofiltration (NF) ceramic membrane have found increasing applications particularly in wastewater and water treatment. In order to estimate and optimize the performance of NF membranes, the membrane should be characterized correctly in terms of their basic parameters such as effective pore radius (rp) and equivalent effective thickness as well as effective surface charge ( ), the effective charge density ( ) and Donnan potential ( ). The impact of electrokinetic (zeta) potential on the membrane surface charge density, effective membrane charge density and Donnan potential at two different concentrations of the reference solutions 0.001, 0.01 M sodium chloride at various pH values from 3 to 9, and effective pore radius (rp) for nominal 0.9 nm  ceramic TiO2 NF membrane were evaluated. Experiments were conducted at cross flow (1.0 m/s) using Microelectrophoresis technique for measuring membrane zeta potential, effective pore radius, and Donnan steric pore model (DSPM). The TiO2 membrane isoelectric point (net membrane charge equals zero) was found at pH of 3.7, 3.5 for 0.001 and 0.01 M NaCl respectively. The results showed that the NF membrane zeta potential changes its sign from positive to negative after the isoelectric point. The evaluated effective pore radius was found to be equal to 0.56 nm by using (DSPM) and the membrane equivalent effective thickness equals to (2×10-6 m).

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Nov 22 2023
Journal Name
Drug And Chemical Toxicology
Preparation, characterization, and toxicity evaluation of microemulsion formulation containing prunetin for potential oral applications
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Nov 01 2023
Journal Name
The Saudi Dental Journal
Salivary lactate dehydrogenase and salivary total protein as potential biomarkers for screening periodontal disease
...Show More Authors

Abstract Background: Timely diagnosis of periodontal disease is crucial for restoring healthy periodontal tissue and improving patients’ prognosis. There is a growing interest in using salivary biomarkers as a noninvasive screening tool for periodontal disease. This study aimed to investigate the diagnostic efficacy of two salivary biomarkers, lactate dehydrogenase (LDH) and total protein, for periodontal disease by assessing their sensitivity in relation to clinical periodontal parameters. Furthermore, the study aimed to explore the impact of systemic disease, age, and sex on the accuracy of these biomarkers in the diagnosis of periodontal health. Materials and methods: A total of 145 participants were categorized into three groups based

... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Dec 31 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DETERMINATION OF CEFALAXIN IN PHARMACEUTICAL PREPARATION BYMOLECULARY IMPRENTED POLYMER IN PVC MATRIX MEMBRANE: DETERMINATION OF CEFALAXIN IN PHARMACEUTICAL PREPARATION BYMOLECULARY IMPRENTED POLYMER IN PVC MATRIX MEMBRANE
...Show More Authors

This current study was built on creating four electrodes based on molecularly imprinted polymers (MIPs). As the template using Cefalexin (CFX), 1-vinyl imidazole (VIZ) and vinyl acetate (VA) as monomer, and N, N-methylene bis acrylamide (MBAA) as cross-linkers and benzoyl peroxide as the initiator, two MIPs were prepared. The same composition was used in non-impressed polymers (NIPs) preparation, but without the template (Cefalexin). For the membranes preparation, numerous plasticizers, such as tri-oly phosphate (TOP) and di-octyl phthalate (DOP), were used in the PVC matrix, slop, detection limit, lifetime, and linearity range of CFX-MIPs electrodes are characteristics &nb

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 11 2024
Journal Name
Research Square
Exploring the Potential of Terrestrial Isopoda, Porcellionides cingendus, for Assessing Environmental Sustainability
...Show More Authors
Abstract<p><bold>Introduction:</bold> Environmental sustainability is crucial for maintaining diverse and productive biological systems. Terrestrial isopods, such as Porcellionides cingendus, are known for their environmentally friendly characteristics and adaptability. This study explores the potential of <italic>P. cingendus</italic> in improving environmental sustainability. <bold>Methods:</bold> Samples of P. cingendus were collected from various locations and reared in controlled environments. Waste consumption efficiency was evaluated by measuring the consumption of various cellulosic wastes over 15 days. Statistical analysis was performed using One-Way ANOVA. <jat></jat></p> ... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad
Serum CXCL 9 as a Potential Biomarker for Patients with Ulcerative Colitis
...Show More Authors

Background: Ulcerative colitis (UC) is an inflammatory bowel disease restricted to the large intestine, characterized by superficial ulceration. It is a progressive and chronic disease requiring long-term treatment. Although its etiology remains unknown, it is suggested that environmental factors influence genetically susceptible individuals, leading to the onset of the disease. (C-X-C) ligand 9 is a chemokine that belongs to the CXC chemokine family, it plays a role in the differentiation of immune cells such as cytotoxic lymphocytes, natural killer T cells, and macrophages. Its interaction with its corresponding receptor CXCR3 which is expressed by a variety of cells such as effector T cells, CD8+ cytotoxic T cells, and macrophage

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu Oct 31 2019
Journal Name
Al-kindy College Medical Journal
Stethoscope as potential occupational hazards for intra hospital carries of pathogenic microorganisms
...Show More Authors

Background: The stethoscope is a tool that doctors use daily in the examination of patients and  it  can take part in the transmission of health care-associated infections. In a single day it may come in direct contact with multiple patients and the intra hospital environment  may be contaminated by various type of bacteria and possibly transmit to others.

Objective:- The study was to know the attitude and knowledge about   the stethoscope hygiene behavior among physicians  and to determine the types of  bacterial agents that can contaminate stethoscopes.

Type of the study: The study was a cross-sectional study

Metho

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Process Optimization Study of Pb(II) Removal by Bulk Liquid Membrane (BLM)
...Show More Authors

   Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Jun 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Upgrading of Al-Rustamiyah Sewage Treatment Plant Through Experimental and Theoretical Analysis of Membrane Fouling
...Show More Authors

Al-Rustamiyah plant is the oldest and biggest sewage treatment plant in Iraq; it locates in the south of Baghdad city. The plant suffers from serious problems associated with overflow and low capacity. The present work aims to upgrade the heart of biological treatment process through suggesting the use of membrane bioreactor; (MBR). In this work, fouling of membrane during sewage treatment has been analyzed experimentally and theoretically by fouling mechanisms. Aeration has been applied in order to control fouling through producing effective diameters of air bubbles close to the membrane walls. Effect of air flow rate on flux decline was investigated. Hermia's models were used to investigate the fouling mechanisms. The results showed th

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process
...Show More Authors

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Desalination of Highly Saline Water Using Direct Contact Membrane Distillation (DCMD)
...Show More Authors

In this work, laboratory experiments were carried out to verify direct contact membrane distillation system’s performance in highly saline water desalination. The study included the investigation of various operating conditions, like feed flow rate, temperature and concentration of NaCl solution and their impact on the permeation flux were discussed. 16 cm2 of a flat sheet membrane module with commercial poly-tetra-fluoroethylene (PTFE) membrane, which has 0.22 μm pore size, 96 µm thickness and 78% average porosity, was used. A high salt rejection factor was obtained greater than 99.9%, and the permeation flux up to 17.27 kg/m2.h was achieved at 65°C for hot feed side and 20°C for cold side stream.

View Publication Preview PDF
Crossref (6)
Crossref