Preferred Language
Articles
/
joe-633
Zeta Potential, Effective Membrane Charge and Donnan Potential for TiO2 NF Ceramic Membrane
...Show More Authors

Nanofiltration (NF) ceramic membrane have found increasing applications particularly in wastewater and water treatment. In order to estimate and optimize the performance of NF membranes, the membrane should be characterized correctly in terms of their basic parameters such as effective pore radius (rp) and equivalent effective thickness as well as effective surface charge ( ), the effective charge density ( ) and Donnan potential ( ). The impact of electrokinetic (zeta) potential on the membrane surface charge density, effective membrane charge density and Donnan potential at two different concentrations of the reference solutions 0.001, 0.01 M sodium chloride at various pH values from 3 to 9, and effective pore radius (rp) for nominal 0.9 nm  ceramic TiO2 NF membrane were evaluated. Experiments were conducted at cross flow (1.0 m/s) using Microelectrophoresis technique for measuring membrane zeta potential, effective pore radius, and Donnan steric pore model (DSPM). The TiO2 membrane isoelectric point (net membrane charge equals zero) was found at pH of 3.7, 3.5 for 0.001 and 0.01 M NaCl respectively. The results showed that the NF membrane zeta potential changes its sign from positive to negative after the isoelectric point. The evaluated effective pore radius was found to be equal to 0.56 nm by using (DSPM) and the membrane equivalent effective thickness equals to (2×10-6 m).

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
DIESEL PARTICULATE EMISSIONS EVALUATION FOR SINGLE CYLINDER ENGINE FUELLED WITH ETHANOL AND GAS-OIL SOLUTIONS
...Show More Authors

Particulate matter (PM) emitted from diesel engine exhaust have been measured in terms of mass, using
99.98 % pure ethanol blended directly, without additives, with conventional diesel fuel (gas – oil),to
get 10 % , 15 %, 20 % ethanol emulsions . The resulting PM collected has been compared with those
from straight diesel. The engine used is a stationary single cylinder, variable compression ratio Ricardo
E6/US. This engine is fully instrumented and could run as a compression or spark ignition.
Observations showed that particulate matter (PM) emissions decrease with increasing oxygenate
content in the fuel, with some increase of fuel consumption, which is due to the lower heating value of
ethanol. The reduction in

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Journal Of Endodontics
Synthesis and Preliminary Evaluation of a Polyolefin-based Core for Carrier-based Root Canal Obturation
...Show More Authors

Introduction: Carrier-based gutta-percha is an effective method of root canal obturation creating a 3-dimensional filling; however, retrieval of the plastic carrier is relatively difficult, particularly with smaller sizes. The purpose of this study was to develop composite carriers consisting of polyethylene (PE), hydroxyapatite (HA), and strontium oxide (SrO) for carrier-based root canal obturation. Methods: Composite fibers of HA, PE, and SrO were fabricated in the shape of a carrier for delivering gutta-percha (GP) using a melt-extrusion process. The fibers were characterized using infrared spectroscopy and the thermal properties determined using differential scanning calorimetry. The elastic modulus and tensile strength tests were dete

... Show More
View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sat Sep 30 2017
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Permeability Prediction By Classical and Flow Zone Indictor (FZI) Methods for an Iraqi Gas Field
...Show More Authors

The permeability is the most important parameter that indicates how efficient the reservoir fluids flow through the rock pores to the wellbore. Well-log evaluation and core measurements techniques are typically used to estimate it. In this paper, the permeability has been predicted by using classical and Flow zone indicator methods. A comparison between the two methods shows the superiority of the FZI method correlations, these correlations can be used to estimate permeability in un-cored wells with a good approximation.

View Publication Preview PDF
Publication Date
Thu Jan 30 2020
Journal Name
Telecommunication Systems
Nature-inspired optimization algorithms for community detection in complex networks: a review and future trends
...Show More Authors

View Publication
Scopus (28)
Crossref (23)
Scopus Clarivate Crossref
Publication Date
Sat Dec 02 2023
Journal Name
Journal Of Engineering
Empirical Study for Capturing and Allocating Significant Risk Factors in School Construction Projects in Iraq
...Show More Authors

In Iraq, more than 1031 school projects have been halted due to disputes and claims resulting from financial, contractual, or other issues. This research aims to identify, prioritize, and allocate the most critical risk factors that threaten these projects’ success for the duration (2017-2022). Based on a multi-step methodology developed through systematic literature reviews, realistic case studies, and semi-structured interviews, 47 risk factors were identified. Based on 153 verified responses, the survey reveals that the top-ranked risk factors are corruption and bribery, delaying the payments of the financial dues to the contractors or sub-contractors, absence of risk management strategy, multiple change orders due

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Dec 18 2017
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Theoretical Study for Performance Enhancement of Air Solar Collectors by Using Different Absorbers
...Show More Authors

An experimental and theoretical study has been done to investigate the thermal performance of different types of air solar collectors, In this work air solar collector with a dimensions of (120 cm x90 cm x12 cm) , was tested under climate condition of  Baghdad city with a (43° tilt angel)  by using  the absorber plate (1.45 mm thickness, 115 cm height x 84 cm width), which was manufactured from iron painted with a black matt.

The experimental test deals with five types of absorber:-

 Conventional smooth flat plate absorber , Finned absorber , Corrugated absorber plate, Iron wire mesh on absorber And matrix of porous media  on absorber .

The hourly and average efficiency of the collectors

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Baghdad Science Journal
Odd Fibonacci edge irregular labeling for some trees obtained from subdivision and vertex identification operations
...Show More Authors

Let G be a graph with p vertices and q edges and  be an injective function, where k is a positive integer. If the induced edge labeling   defined by for each is a bijection, then the labeling f is called an odd Fibonacci edge irregular labeling of G. A graph which admits an odd Fibonacci edge irregular labeling is called an odd Fibonacci edge irregular graph. The odd Fibonacci edge irregularity strength ofes(G) is the minimum k for which G admits an odd Fibonacci edge irregular labeling. In this paper, the odd Fibonacci edge irregularity strength for some subdivision graphs and graphs obtained from vertex identification is determined.

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
Journal Of Engineering
Checking the Accuracy of Selected Formulae for both Clear Water and Live Bed Bridge Scour
...Show More Authors

Due to severe scouring, many bridges failed worldwide. Therefore, the safety of the existing bridge (after contrition) mainly depends on the continuous monitoring of local scour at the substructure. However, the bridge's safety before construction mainly depends on the consideration of local scour estimation at the bridge substructure. Estimating the local scour at the bridge piers is usually done using the available formulae. Almost all the formulae used in estimating local scour at the bridge piers were derived from laboratory data. It is essential to test the performance of proposed local scour formulae using field data. In this study, the performance of selected bridge scours estimation formulae was validated and sta

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jul 01 2018
Journal Name
Pakistan Journal Of Biotechnology
Correlation between BOD5 and COD for Al-Diwaniyah wastewater treatment plants to obtain biodegradability indices.
...Show More Authors

The present study aims to establish an empirical correlation between biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) of the sewage flowing in Al-Diwaniyah wastewater treatment plant. The strength of the wastewater entering the plant varied from medium to high. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. Regression equations for BOD5 and COD removal percentages were suggested which can be used to evaluate rapid effluent assessment after the treatment processes or optimal process control to improve the performance of wastewater treatment plants.

... Show More
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Seismic Effects and Static Analysis for the Artificial Damped Outrigger Systems in Tall R.C Buildings
...Show More Authors

This paper studies the combination fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. It works by connecting the central core, comprising either shear walls or braced frames, to the outer perimeter columns.

     The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model, and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximum lateral load at the top of the building is calculated, and  this load  w

... Show More
View Publication Preview PDF