Determination of Best Location for Elevated Tank in Branched Network
...Show More Authors

The research focuses on determination of best location of high elevated tank using the required head of pump as a measure for this purpose. Five types of network were used to find the effect of the variation in the discharge and the node elevation on the best location. The most weakness point was determined for each network. Preliminary tank locations were chosen for test along the primary pipe with same interval distance. For each location, the water elevation in tank and pump head was calculated at each hour depending on the pump head that required to achieve the minimum pressure at the most weakness point. Then, the sum of pump heads through the day was determined. The results proved that there is a most economical location where the energy consumption is minimum. This location joined with the branched line that containing the most weakness point. The best location didn’t join with the highest demand location unless this location containing the most weakness point.  The results indicated that the moving of tank away from best location in pump direction result in pump head increasing that exceed the increasing in pump head when the tank moves in the opposite direction. The location of tank beside the pump station was the worst location. Also, the results showed that as the distance between the pump and the highest demand become shorter, the required pump head become less. The uniform demand distribution required the least amount of pump head, it required minimum head of (554)m while the networks, that have highest demand at distance 200m,400m, and 1000m from the pump station,  required minimum head of 651m, 682m, and 726m respectively.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 12 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Mefenamic Acid in Pharmaceutical Preparations
...Show More Authors

  A simple, accurate and precise spectrophotometric method has been proposed for the determination of Mefenamic acid(MA) in dosage forms. Proposed  method based on the reaction of cited drug with 1,2-Naphthoquinone-4-Sulfonic sodium (NQS). The optimum experimental condition have been studied. Beer's Law is obeyed in the concentration range 0.5-10.0 µg/mL at 450nm with detection limit of 0.189µg/mL.  Effect of pH, reaction time, and volume of NQS on the determination of Mefenamic acid, have been examined. The proposed method has been successfully applied for the determination of  Mefenamic acid in pharmaceutical preparations.
 

View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Amiodarone Hydrochloride in Pharmaceutical Preparations
...Show More Authors

Amiodarone hydrochloride (AH) has been determined spectrophotometrically Using methyl orange (MO).  In our previous researches MO was used for determination of Mexiletine Hydrochloride [1]. The method based on complexation between MO and AH.  After shaking and diluting the complex solution with D.W, the pH was adjusted with NaOH and HCl to pH 3. The colored complex formed between AH and the reagent were transferred into separating funnels and extracted using 5.5ml CH2Cl2 and were shaken for (5 minutes).  The extracted organic layer was used for preparation of the calibration curves for spectrophotometric measurements of AH at 434nm.  The blanks were carried out in exactly the same way throughout the whole procedure.&n

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 01 2009
Journal Name
Wasit Journal For Science & Medicine
Spectrophotometric Determination of Promethazine Hydrochloride by In (III)
...Show More Authors

A simple, rapid and sensitive spectrophotometirc method for the determination of trace amounts of promethazine hydrochloride in the aqueous solution is described. The method is based on the complexation of promethazine hydrochloride with In (III) in the presence of sodium hydroxide to form an soluble product with maximum absorption at 304nm. Beer’s law is obeyed over the concentration range of (2- 20μg/ml) with molar absorptivity of (1.92× 103 L.mol-1 .cm -1 ). The optimum conditions for all development are described and the proposed method has been successfully applied for the determination of promethazine hydrochloride in bulk drug.

Publication Date
Mon Nov 20 2028
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
DETERMINATION OF OPTIMAL CONDITIONS FOR CAROTENOIDS PRODUCTION BY CHEMICAL MUTANAT LOCAL ISOLATE RHODOTORUL MUCILAGENOSA M.: DETERMINATION OF OPTIMAL CONDITIONS FOR CAROTENOIDS PRODUCTION BY CHEMICAL MUTANAT LOCAL ISOLATE RHODOTORUL MUCILAGENOSA M.
...Show More Authors

The aim of this study was to increasing natural carotenoides production by a locally isolate Rodotorula mucilagenosa M. by determination of the optimal conditions for growth and production of this agents, for encouragest to use it in food application permute artificial pigments which harmfull for consumer health and envieronmental. The optimal condition of carotenoides production from Rhodotorula mucilaginosa M were studied. The results shows the best carbon and nitrogen source were glucose and yeast extract. The carotenoids a mount production was 47430 microgram ̸ litter and 47460 microgram ̸ litter, respectively, and the optimum temperature was 30°C, PH 6, that the carotenoides a mount was 47470 microgram ̸ litter and 47670 microgr

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Link Failure Recovery for a Large-Scale Video Surveillance System using a Software-Defined Network
...Show More Authors

The software-defined network (SDN) is a new technology that separates the control plane from data plane for the network devices. One of the most significant issues in the video surveillance system is the link failure. When the path failure occurs, the monitoring center cannot receive the video from the cameras. In this paper, two methods are proposed to solve this problem.  The first method uses the Dijkstra algorithm to re-find the path at the source node switch. The second method uses the Dijkstra algorithm to re-find the path at the ingress node switch (or failed link).

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Apr 24 2018
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Use of Acidic Hydrolysis and Diazo Coupling Reaction for Spectrophotometric Determination of Furosemide in Urine and Pharmaceutical Formulation.
...Show More Authors

     Simple and rapid spectrophotometric determination of furosemide (FUR) has been investigated .The method is based on acid hydrolysis of FUR to free primary aromatic amine and diazotization followed by coupling with 3, 5 di methyl phenol (3, 5-DMPH) at basic medium. The absorbance was measured at 434 nm, the method was optimized for best condition, and beers’ law is obeyed over the range of 0.4-50 µg.mL-1 with molar absorptivity and sandal’s sensitivity 1.3899 x104 L moL-1 .cm-1 and 0.0238x104 µg.cm-2 respectively. Analysis of solution containing nineteen different concentrations of FUR gave a correlation coefficient of (0.9999) a

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun May 07 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Development Of Two Different Spectrophotometric Methods For The Determination Of Atropine Drug In Pure Form And Pharmaceutical Preparations
...Show More Authors

Two methods have been applied for the spectrophotometric determination of atropine, in
bulk sample and in dosage form. The methods are accurate, simple, rapid, inexpensive and
sensitive. The first method depending on the extraction of the formed ion-pair complex with
bromphenol blue (BPB) as a chromogenic reagent in chloroform, use phthalate buffer of pH
3.0; which showed absorbance maxima at 413 nm against reagent blank. The calibration
graph is linear in the ranges of 0.5-40 µg.mL
-1
with detection limit of 0.363µg.mL
-1
. The
second method depending on the measure of the absorbance maxima of the formed charge-transfer complex with 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) at 457 nm against

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 25 2017
Journal Name
International Journal On Advanced Science, Engineering And Information Technology
A Novel DNA Sequence Approach for Network Intrusion Detection System Based on Cryptography Encoding Method
...Show More Authors

A novel method for Network Intrusion Detection System (NIDS) has been proposed, based on the concept of how DNA sequence detects disease as both domains have similar conceptual method of detection. Three important steps have been proposed to apply DNA sequence for NIDS: convert the network traffic data into a form of DNA sequence using Cryptography encoding method; discover patterns of Short Tandem Repeats (STR) sequence for each network traffic attack using Teiresias algorithm; and conduct classification process depends upon STR sequence based on Horspool algorithm. 10% KDD Cup 1999 data set is used for training phase. Correct KDD Cup 1999 data set is used for testing phase to evaluate the proposed method. The current experiment results sh

... Show More
View Publication
Scopus (9)
Crossref (5)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Priority Based Transmission Rate Control with Neural Network Controller in WMSNs
...Show More Authors

Wireless Multimedia Sensor Networks (WMSNs) are networks of wirelessly interconnected sensor nodes equipped with multimedia devices, such as cameras and microphones. Thus a WMSN will have the capability to transmit multimedia data, such as video and audio streams, still images, and scalar data from the environment. Most applications of WMSNs require the delivery of multimedia information with a certain level of Quality of Service (QoS). This is a challenging task because multimedia applications typically produce huge volumes of data requiring high transmission rates and extensive processing; the high data transmission rate of WMSNs usually leads to congestion, which in turn reduces the Quality of Service (QoS) of multimedia appli

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 01 2014
Journal Name
Journal Of Engineering
Priority Based Transmission Rate Control with Neural Network Controller in WMSNs
...Show More Authors

Wireless Multimedia Sensor Networks (WMSNs) are networks of wirelessly interconnected sensor nodes equipped with multimedia devices, such as cameras and microphones. Thus a WMSN will have the capability to transmit multimedia data, such as video and audio streams, still images, and scalar data from the environment. Most applications of WMSNs require the delivery of multimedia information with a certain level of Quality of Service (QoS). This is a challenging task because multimedia applications typically produce huge volumes of data requiring high transmission rates and extensive processing; the high data transmission rate of WMSNs usually leads to congestion, which in turn reduces the Quality of Service (QoS) of multimedia applications. To

... Show More
View Publication