Preferred Language
Articles
/
joe-601
Direct Contact Membrane Distillation for Separation of Hcl From A Mixture of Acids

HCl is separated from HCl –H2SOsolution by membrane distillation process(MD). The flat –sheet membranes made from polyvinylidene fluoride (PVDF) and polypropylene (pp.). Plate and frame these types of membrane where used in the process. The feed is a mixture of HCl and H2SO4 acids compositions depended on metals treated object.HCl concentration increased in the permeate during the process but sulfuric acid increased gradually in the feed .During the concentration of solution acids concentrations in the feed at the beginning were 50 g/dm3 of sulfuric acid and 50 g/dm3 of hydrochloric acid at 333K feed temperature the permeate flux was 71 dm3/m2.d. At a higher  concentration of HCl  in the feed  111g /dm3  and 61 g/ dm3 of sulfuric acid  at the feed temperature 333K  volume permeate flux was 57 dm3/ m2.d . At a higher concentration of  sulfuric acid  in the feed 161 g/dm3 and 60 g/dm3 of HCl decrease the permeate flux from 71 to 35 dm3/m2.d at 333K . The permeate flux increase from 35 at 333K to 85 at 343 K increase the temperature caused an increase in permeate flux. Increases in sulfuric acid concentration from 50 to 161 g/dm3 decrease the volume permeate flux from 71 to 35 dm3 /m2.d, HCl concentration was achieved a higher value 9.1 g/dm3 during the process at the feed concentration 161g/dm3 of sulfuric acid and 60g/dm3 of hydrochloric acid at feed temperature 343K.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
A new approach for the topical treatment of acne vulgaris by clindamycin HCL supported on kalion

Has been studied both processes Almetzaz and extortion of a substance Alklanda Maysan different amounts of Alcaúlan Guy 70% alcohol solution using the method when the wavelength

View Publication Preview PDF
Publication Date
Wed Mar 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
ESTIMATION OF MASS TRANSFER COEFFICIENTS IN A PACKED DISTILLATION COLUMN USING BATCH MODE

This research adopts the estimation of mass transfer coefficient in batch packed bed distillation column as function of physical properties, liquid to vapour molar rates ratio (L / V), relative volatility (α), ratio of vapour and liquid diffusivities (DV / DL), ratio of vapour and liquid densities (ρV / ρL), ratio of vapour and liquid viscosities (μV/ μL).
The experiments are done using binary systems, (Ethanol Water), (Methanol Water), (Methanol Ethanol), (Benzene Hexane), (Benzene Toluene). Statistical program (multiple regression analysis) is used for estimating the overall mass transfer coefficient of vapour and liquid phases (KOV and KOL) in a correlation which represented the data fairly well.

KOV = 3.3 * 10-10

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Mon Mar 03 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Apparent Viscosity Direct from Marsh Funnel Test

Accurate and simple techniques for measurement of fluid rheological properties are important for field operations in the oil industry. Marsh Funnels are popular qualitycontrol tools used in the field for drilling fluids and they offer a simple, practical alternative to viscosity measurement. In the normal measurements, a single point (drainage time) is used to determine an average viscosity; little additional information is extracted regarding the non-Newtonian behavior of the fluid. Here, a new model is developed and used to determine the rheological properties of drilling muds and other non-Newtonian fluids using data of fluid density and drainage time collected from a Marsh Funnel as a function of viscosity. The funnel results for viscos

... Show More
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Apparent Viscosity Direct from Marsh Funnel Test

Accurate and simple techniques for measurement of fluid rheological properties are important for field operations in the oil industry. Marsh Funnels are popular quality-control tools used in the field for drilling fluids and they offer a simple, practical alternative to viscosity measurement. In the normal measurements, a single point (drainage time) is used to determine an average viscosity; little additional information is extracted regarding the non-Newtonian behavior of the fluid.
Here, a new model is developed and used to determine the rheological properties of drilling muds and other non-Newtonian fluids using data of fluid density and drainage time collected from a Marsh Funnel as a function of viscosity. The funnel results for

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 07 2013
Journal Name
International Journal Of Pharma Sciences
Separation and Purification of Hemolysin from Local Isolate of Serratia marcescens

Twenty isolates of Serratia marcescens were isolated from inflammation of the urinary tract (UTI)., These isolates were found to produce hemolysin as indicated by blood agar plates in which the hemolysis of red blood cell indicate a positive result. Isolates were selected according to their hemolysis activity by measuring absorbance of hemoglobin at 405 nm that released from red blood cell. Hemolysin was completely purified using 50-75% saturation of ammonium sulphate followed by ion exchange chromatography with DEAE-cellulose then gel filtration chromatography by sepharose 4B. Accordingly molecular weight for the purified toxin was estimated as 45 KD.

Publication Date
Mon Sep 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of-Copper Ions-from Aqueous Solution Using Liquid-Surfactant-Membrane Technique

Extraction of copper (Cu) from aqueous solution utilizing Liquid Membrane technology (LM) is more effective than precipitation method that forms sludge and must be disposed of in landfills. In this work, we have formulated a liquid surfactant membrane (LSM) that uses kerosene oil as the main diluent of LSM to remove copper ions from the aqueous waste solution through di- (2-ethylhexyl) phosphoric acid - D2EHPA- as a carrier. This technique displays several advantages including one-stage extraction and stripping process, simple operation, low energy requirement, and. In this study, the LSM process was used to transport Cu (II) ions from the feed phase to the stripping phase, which was prepared, using H2SO4. For LSM p

... Show More
Crossref (9)
Crossref
View Publication Preview PDF
Publication Date
Fri Mar 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Pelletierine from Punica granatum L.by Liquid Membrane Technique and Modelling

This work was conducted to study the extraction of pelletierine sulphate from Punica granatum L. roots by liquid membrane techniques. Pelletierine sulphate is used widely in medicine. The general behavior of extraction process indicates that pelletierine conversion increased with increasing the number of stages and the discs rotation speed but high rotation speed was not favored because of the increased risk of droplet formation during the operation. The pH of feed and acceptor solution was also important. The results exhibit that the highest pelletierine conversion was obtained when using two stages,(10 rpm) discs speed of stainless steel discs,(pH= 9.5) of feed solution and (pH= 2) of acceptor solution in n-decane. Assuming the existence

... Show More
Publication Date
Fri Mar 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Extraction of Pelletierine from Punica granatum L.by Liquid Membrane Technique and Modelling

This work was conducted to study the extraction of pelletierine sulphate from Punica granatum L. roots by liquid membrane techniques. Pelletierine sulphate is used widely in medicine. The general behavior of extraction process indicates that pelletierine conversion increased with increasing the number of stages and the discs rotation speed but high rotation speed was not favored because of the increased risk of droplet formation during the operation. The pH of feed and acceptor solution was also important. The results exhibit that the highest pelletierine conversion was obtained when using two stages, (10 rpm) discs speed of stainless steel discs, (pH=9.5) of feed solution and (pH=2) of acceptor solution in n-decane. Assuming the existen

... Show More
View Publication Preview PDF
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Zirconium Sulfate as Catalyst for Biodiesel Production by Using Reactive Distillation

Production of fatty acid esters (biodiesel) from oleic acid and 2-ethylhexanol using sulfated zirconia as solid catalyst for the production of biodiesel was investigated in this work.

 

       The parameters studied were temperature of reaction (100 to 130°C), molar ratio of alcohol to free fatty acid (1:1 to 3:1), concentration of catalyst (0.5 to 3%wt), mixing speed (500 to 900 rpm) and types of sulfated zirconia (i.e modified, commercial, prepared  catalyst according to literature and reused catalyst). The results show the best conversion to biodiesel was 97.74% at conditions of 130°C, 3:1, 2wt% and 650 rpm using modified catalyst respectively. Also, modified c

... Show More
View Publication Preview PDF