Preferred Language
Articles
/
joe-590
Performance Evaluation of Plant Produced Warm Mix Asphalt
...Show More Authors

Warm mix asphalt (WMA) is relatively a new technology which enables the production and compaction of asphalt concrete mixtures at temperatures 15-40 °C lower than that of traditional hot mix asphalt HMA. In the present work, six asphalt concrete mixtures were produced in the mix plant (1 ton each) in six different batches. Half of these mixes were WMA and the other half were HMA.  Three types of fillers (limestone dust, Portland cement and hydrated lime) were used for each type of mix. Samples were then taken from these patches and transferred to lab for performance testing which includes: Marshall characteristics, moisture susceptibility (indirect tension test), resilient modulus, permanent deformation (axial repeated load test) and fatigue characteristics (third point flexural beam test). The obtained results indicated that the performance of WMA is enhanced when using the hydrated lime as filler in comparison with the limestone dust and Portland cement fillers. Better fatigue life was obtained for WMA using hydrated lime filler in comparison with HMA. Regardless the filler type, the Marshall properties of WMA satisfy the requirement of local specification, other properties of WMA were relatively lower than the HMA.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Civil Engineering And Technology (ijciet)
Effluent quality assessment of Al-Diwaniyah sewage treatment plant based on wastewater quality index
...Show More Authors

Treated effluent wastewater is considered an alternative water resource which can provide an important contribution for using it in different purposes, so, the wastewater quality is very important for knowing its suitability for different uses before discharging it into fresh water ecosystems. The wastewater quality index (WWQI) may be considered as a useful and effective tool to assess wastewater quality by indicating one value representing the overall characteristic of the wastewater. It could be used to indicate the suitability of wastewater for different uses in water quality management and decision making. The present study was conducted to evaluate the Al-Diwaniyah sewage treatment plant (STP) effluent quality based on wastewa

... Show More
Publication Date
Thu Dec 31 2015
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Simulation the Radiation Zone of Al-Mussaib Power Plant by Using Monte Carlo Method
...Show More Authors

The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found.

   Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Plant Archives
Effect of salinity stress and selenium spraying on broad bean plant Vicia faba L.
...Show More Authors

The experiment was conducted in the old botanical garden belong to Biology Department/ College of Education for Pure Science - Ibn Al-Haitham/Baghdad University for growing season 2015-2016 to study the effect of irrigation with four concentrations of sodium chloride (0, 50, 100, 150) mM.L-1 and spraying with selenium in three concentrations (0, 10, 20) mgL-1 on growth of broad bean plant using clay pots. The experiment was design according to completely randomized design (CRD) with three replications. Results indicated that broad bean plant irrigated with saline water and increasing concentrations of sodium chloride in growth medium caused a significant decreased in the plant growth parameters (plant height, no. of compound leaves. Plant-1

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Thu Dec 29 2016
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Solvent Extraction of Phenolic Compounds and Determination Total Phenolic Content from Teucrium Polium Plant
...Show More Authors

       A direct solvent extraction was used for the determination of phenolic compounds from Teucrium polium . Methanol, ethanol, iso-propanol, butanol and D.W  were used as an extractants and study  the affecting extraction factors including : the type and solvent concentration, temperature, extraction time and number of batch extraction, by  using Folin-ciocalteu method to determine the Total Phenolic Content (TPC) and measurement of the absorbance at λmax 765nm. The accuracy and precision of this method were determined by preparing laboratory samples of Gallic acid , the results showed relative errors ranging from ±0.5 – 1.49 % and the standard deviation equal to 1.2

... Show More
View Publication Preview PDF
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Kinetic and Theoretical Study of Removal Gentian Violet from Aqueous Solution Using Stachy Plant
...Show More Authors

     The main parameters and methods influencing the removal of Gentian Violet (GV) dye from aqueous media were investigated using a stachy plant in this study. The surface of the stachy plant was determined using FTIR spectra. Adsorption is influenced by the adsorbent's characteristic groups. The research took into account the usual conditions for GV dye adsorption by the stachy plant, such as the impact of contact time. Mass dosage , after 0.3 g the amount of adsorbed dye declines. Study pH and ionic strength, the results obtained showed that at pH 3 the largest adsorption of (GV) was seen, while at pH 9, the lowest adsorption was observed  at 298 K, the adsorption kinetics and equilibrium constants were achieved, and the equilibr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 04 2017
Journal Name
Journal Of Chemical And Pharmaceutical Research
Lead, Cadmium and Nickel contamination of roadside soils and plant leaves in Baghdad City
...Show More Authors

Publication Date
Sun Dec 31 2000
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Minimization of Chloride and Sulphate Ions Concentrations in the Effluents from an Elctroplating Plant
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Sep 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Simulation the Radiation Zone of Al-Mussaib Power Plant by using Monte Carlo Method
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
The Potential of some Plant Extracts as Radical Scavengers and Dipeptidyl Peptidase-4 Inhibitors
...Show More Authors

Seeds, beans, leaves, fruit peel and seeds of five plants (Ferula assa-foetida, Coffea robusta, Olea europaea, Punica granatum and Vitis vinifera, respectively) were extracted with four solvents (distilled water, 80% methanol, 80% acetone and a mixed solvent that included methanol, ethanol, acetone and n-butanol at proportions 7:1:1:1). Such manipulation yielded 20 extracts, which were phytochemically analyzed for total polyphenols (TP) and flavonoids (TF). The DPPH (2,2-diphenyl-1-picrylhydrazyl) radical scavenging activity (RSA) and DPP-4 (dipeptidyl peptidase-4) relative inhibition activity (RIA) were also assessed for each extract. The results revealed that mixed solvent extract of V.

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Dec 05 2021
Journal Name
Iraqi Journal Of Science
Heavy Metals Pollution Assessment of the Water in Al-Quds Power Plant in Baghdad
...Show More Authors

Sixteen water samples were collected from the operation units of the Al-Quds
power plant, north Baghdad city and the surrounding trocars, surface and
groundwater, and analyzed to assess the resulting pollution. The samples were
analyzed for heavy metals (As, Cd, Cr, Cu, Mn, Mo, Ni, Pb, Sb, Se, U and Zn) by
using inductively coupled plasma- mass spectrometry (ICP-MS). The results were
compared with local and international and standard limits. Heavy metals analysis of
the water samples shows that water of operation units and trocars have mean
concentrations of As, Cd, Cr, Cu, Mo, Pb, Sb, Se, U and Zn were within or lower
than the national and world limits, while Mn and Ni were higher than these limits.
Concentrat

... Show More
View Publication Preview PDF