Preferred Language
Articles
/
joe-570
Energy and Exergy Analysis of Dual Channel Solar Air Collector with Different Absorber Plates Geometry
...Show More Authors

Flat-plate collector considers most common types of collectors, for ease of manufacturing and low price compared with other collectors. The main aim of the present work is to increase the efficiency of the collector, which can be achieved by improving the heat transfer and minimize heat loss experimentally. Five types of solar air collectors have been tested, which conventional channel with a smooth absorber plate (model I), dual channel with a smooth absorber plate (model II), dual channel with perforating “V” corrugated absorber plate (model III), dual channel with internal attached wire mesh (model Ⅳ), and dual channel with absorber sheet of transparent honeycomb, (model Ⅴ). The dual channel collector used for increasing heat transfer area and heat removal factor to improve thermal performance. The outdoor test was conducted during the period December (2016) to February (2017) at different mass flow rates 0.0217 kg/s, 0.0271 kg/s and 0.0325 kg/s. The experiments were carried out from 8:30 AM to 3:00 PM for clear days. Experimental results show that the average thermal efficiency was (72.2 %) for model (III), (40.2 %) for model (I), (51.6 %) for model (II), (65.1 %) for model (Ⅳ) and (59.7 %) for model (Ⅴ). At the last part of the study, the exergy analyses were derived for both collectors. The results of this part showed that the conventional channel model (I) is having largest irreversibility, and the dual channel collector model (III) is having a greatest exergetic efficiency.

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Engineering
Using a New Modification on Wind Turbine Ventilator for Improving Indoor Air Quality
...Show More Authors

This paper describes a newly modified wind turbine ventilator that can achieve highly efficient ventilation. The new modification on the conventional wind turbine ventilator system may be achieved by adding a Savonius wind turbine above the conventional turbine to make it work more efficiently and help spinning faster. Three models of the Savonius wind turbine with 2, 3, and 4 blades' semicircular arcs are proposed to be placed above the conventional turbine of wind ventilator to build a hybrid ventilation turbine. A prototype of room model has been constructed and the hybrid turbine is placed on the head of the room roof. Performance's tests for the hybrid turbine with a different number of blades and different values o

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Comparative Reliability Analysis between Horizontal-Vertical-Diagonal Code and Code with Crosstalk Avoidance and Error Correction for NoC Interconnects
...Show More Authors

Ensuring reliable data transmission in Network on Chip (NoC) is one of the most challenging tasks, especially in noisy environments. As crosstalk, interference, and radiation were increased with manufacturers' increasing tendency to reduce the area, increase the frequencies, and reduce the voltages.  So many Error Control Codes (ECC) were proposed with different error detection and correction capacities and various degrees of complexity. Code with Crosstalk Avoidance and Error Correction (CCAEC) for network-on-chip interconnects uses simple parity check bits as the main technique to get high error correction capacity. Per this work, this coding scheme corrects up to 12 random errors, representing a high correction capac

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Agricultural Engineering
Analysis of the Vacuum-Steam Defrosting Process of Plums Pre-Treated with Dehydrofreezing
...Show More Authors
Abstract<p>The research material was prune plums (<italic>Prunus domestica</italic> L.), subjected to osmotic pre-treatment, with variable process time parameters and osmotic solution concentration. Plums thus fixed were frozen and stored for 6 months. At even (monthly) intervals, the product was defrosted by the vacuum-steam method, using the s-p-p chamber, until the thermocouple indicated a temperature of 4ºC in the sample’s thermal center. In order to study the kinetics of phenomena occurring during the defrosting process, the chamber was equipped with a measuring system to enable measurement and recording of temperature changes in time in the geometric center of the sample, as w</p> ... Show More
Scopus (1)
Scopus Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Agricultural Engineering
Analysis of the Vacuum-Steam Defrosting Process of Plums Pre-Treated with Dehydrofreezing
...Show More Authors
Abstract<p>The research material was prune plums (<italic>Prunus domestica</italic> L.), subjected to osmotic pre-treatment, with variable process time parameters and osmotic solution concentration. Plums thus fixed were frozen and stored for 6 months. At even (monthly) intervals, the product was defrosted by the vacuum-steam method, using the s-p-p chamber, until the thermocouple indicated a temperature of 4ºC in the sample’s thermal center. In order to study the kinetics of phenomena occurring during the defrosting process, the chamber was equipped with a measuring system to enable measurement and recording of temperature changes in time in the geometric center of the sample, as w</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Conference Of Numerical Analysis And Applied Mathematics Icnaam 2019
Investigate of TiO2 and SnO2 as electron transport layer for perovskite solar cells
...Show More Authors

View Publication
Scopus (19)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Desalination And Water Treatment
Optimization and kinetic evaluation of reactive yellow dye degradation by solar photocatalytic process
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Journal Of Engineering
Experimental and Simulation for the Effect of Partial Shading on Solar Panel Performance
...Show More Authors

Partial shading is one of the problems that affects the power production and the efficiency of photovoltaic module. A series of experimental work have been done of partial shading of   monocrystalline PV module; 50W, Isc: 3.1A, Voc: 22V with 36 cells in series is achieved. Non-linear power output responses of the module are observed by applying various cases of partial shading (vertical and horizontal shading of solar cells in the module). Shading a single cell (corner cell) has the greatest impact on output energy. Horizontal shading or vertical shading reduced the power from 41W to 18W at constant solar radiation 1000W/m2 and steady state condition. Vertical blocking a column

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Key Engineering Materials
Synthesis and Characterization of the Thin Films NiSe2/Si Heterojunction for Solar Cells
...Show More Authors

Thin film solar cells are preferable to the researchers and in applications due to the minimum material usage and to the rising of their efficiencies. In particular, thin film solar cells, which are designed based one transition metal chalcogenide materials, paly an essential role in solar energy conversion market. In this paper, transition metals with chalcogenide Nickel selenide termed as (NiSe2/Si) are synthesized. To this end, polycrystalline NiSe2 thin films are deposited through the use of vacuum evaporation technique under vacuum of 2.1x10-5 mbar, which are supplied to different annealing temperatures. The results show that under an annealed temperature of 525 K,

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
The effect of Tilt Angle, Surface Azimuth and Mirror in Solar Cell Panel Output in Baghdad.
...Show More Authors

In this research (100* 40* 4 cm) solar cell panel was used in Baghdad at autumn season (2010), to get best solar cell panel angles experimentally, and then a mirror (40*50 cm) is use to concentrate incident sunlight intensity on a panel. At first case we get (Tilt angle ?P =60°and Surface Azimuth angle ?P =36°E) is the best angles and other case, we add a mirror at angle = 120° at bottom of panel, then we get output power (27.48watt) is bigger than without using a mirror (25.16watt). We can benefit from these cases in variety applications.

View Publication Preview PDF
Crossref
Publication Date
Mon Nov 10 2025
Journal Name
Journal Of Physical Education
Exercises With Different Ranges Of Motion With Significance Of Electrical Activity for Muscle in Strength With Speed Of Lower Limbs For Weight Lifters Of Physical Strength
...Show More Authors

View Publication