Using a New Modification on Wind Turbine Ventilator for Improving Indoor Air Quality
...Show More Authors

This paper describes a newly modified wind turbine ventilator that can achieve highly efficient ventilation. The new modification on the conventional wind turbine ventilator system may be achieved by adding a Savonius wind turbine above the conventional turbine to make it work more efficiently and help spinning faster. Three models of the Savonius wind turbine with 2, 3, and 4 blades' semicircular arcs are proposed to be placed above the conventional turbine of wind ventilator to build a hybrid ventilation turbine. A prototype of room model has been constructed and the hybrid turbine is placed on the head of the room roof. Performance's tests for the hybrid turbine with a different number of blades and different values of wind speeds have been conducted. The experimental test results show that the performance of the improved ventilation turbine with three blades is the best. It is found that the maximum rotation speed of the improved turbine is 107rpm, while the air flow rate is 0.0103m3/s and the air change rate per hour is 32.67hr-1, at a wind speed of 3m/s. The proposed design has been achieved an increase in the turbine rotational speed, increase of the extraction rate of the indoor air and the air-changes per hour, provided the requisite ventilation and improved the quality of the indoor air.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Clarifying Optimum Setting Temperatures and Airflow Positions for Personal Air Conditioning System on Flight
...Show More Authors

In recent years, the demand for air travel has increased and many people have traveled by plane. Most passengers, however, feel stressed due to the limited cabin space. In order to make these passengers more comfortable, a personal air-conditioning system for the entire chair is needed. This is because the human body experiences discomfort from localized heating or cooling, and thus, it is necessary to provide appropriate airflow to each part of the body. In this paper, a personal air-conditioning system, which consists of six vertically installed air-conditioning vents, will be proposed. To clarify the setting temperature of each vent, the airflow around the passenger and the operative temperature of each part of the body is investigate

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
The role of compensation system in improving the quality of educational services (Halabja University as a model)
...Show More Authors

          This study deals with the role of compensation system in improving the quality of educational services (University of Halabja as a Model) also our problem was the following question ; What is the role of compensation system in its different dimensions in improving the quality of educational services? And what is the relationship and impact of using the dimensions of the compensation system to improve the quality of educational services? The hypothesis of the research included the correlation and the impacts between the compensation system and its combined variables in the quality of educational services. This was proved through a field study and the distribution of questionn

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Academy Of Accounting And Financial Studies Journal
Impact of Digital Audit on Improving performance Quality and Reduce Costs An applied research in a sample of private auditing firms and offices
...Show More Authors

Publication Date
Sat Jan 01 2022
Journal Name
Materials Today: Proceedings
Hydraulic behaviour and improving of water quality of the Chibayish Marshes
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu May 30 2024
Journal Name
Iraqi Journal Of Science
An Evolutionary Algorithm for Improving the Quantity and Quality of the Detected Complexes from Protein Interaction Networks
...Show More Authors

One of the recent significant but challenging research studies in computational biology and bioinformatics is to unveil protein complexes from protein-protein interaction networks (PPINs). However, the development of a reliable algorithm to detect more complexes with high quality is still ongoing in many studies. The main contribution of this paper is to improve the effectiveness of the well-known modularity density ( ) model when used as a single objective optimization function in the framework of the canonical evolutionary algorithm (EA). To this end, the design of the EA is modified with a gene ontology-based mutation operator, where the aim is to make a positive collaboration between the modularity density model and the proposed

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 01 2025
Journal Name
Al-khwarizmi Engineering Journal
Improving Barcode Vision Scanning Process using a Drone-based Tracking PID Controller for Warehouse in Industry 4.0
...Show More Authors

Drones play a vital role in the fundamental aspects of Industry 4.0 by converting conventional warehouses into intelligent ones, particularly in the realm of barcode scanning. Various potential issues frequently arise during barcode scanning by drones, specifically when the drone camera has difficulty obtaining distinct images due to certain factors, such as distance, capturing the image whilst flying, noise in the environment and different barcode dimensions. In addressing these challenges, this study proposes an approach that combines a proportional–integral–derivative (PID) controller with image processing techniques. The PID controller is responsible for continuously monitoring the camera’s input, detecting the difference

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Engineering
A Comparison Study of Brine Desalination using Direct Contact and Air Gap Membrane Distillation
...Show More Authors

Membrane distillation (MD) is a hopeful desalination technique for brine (salty) water. In this research, Direct Contact Membrane Distillation (DCMD) and  Air Gap Membrane Distillation (AGMD) will be used. The sample used is from Shat Al –Arab water (TDS=2430 mg/l). A polyvinylidene fluoride (PVDF) flat sheet membrane was used as a flat sheet form with a plate and frame cell. Several parameters were studied, such as; operation time, feed temperature, permeate temperature, feed flow rate. The results showed that with time, the flux decreases because of the accumulated fouling and scaling on the membrane surface. Feed temperature and feed flow rate had a positive effect on the permeate flux, while permeate temperatu

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Aug 22 2019
Journal Name
Separation Science And Technology
Modification of Langmuir model for simulating initial pH and temperature effects on sorption process
...Show More Authors

Scopus (45)
Crossref (31)
Scopus Clarivate Crossref
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Estimation Liquid Permeability Using Air Permeability Laboratory Data
...Show More Authors

Permeability data has major importance work that should be handled in all reservoir simulation studies. The importance of permeability data increases in mature oil and gas fields due to its sensitivity for the requirements of some specific improved recoveries. However, the industry has a huge source of data of air permeability measurements against little number of liquid permeability values. This is due to the relatively high cost of special core analysis.
The current study suggests a correlation to convert air permeability data that are conventionally measured during laboratory core analysis into liquid permeability. This correlation introduces a feasible estimation in cases of data loose and poorly consolidated formations, or in cas

... Show More
View Publication Preview PDF
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study on Double-Pass Solar Air Heater with and without using Phase Change Material
...Show More Authors

In this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant

... Show More
View Publication Preview PDF
Crossref (24)
Crossref