Rotating Ceramic Water Filter Discs System for Water Filtration
...Show More Authors

This work aimed to design, construct and operate a new laboratory scale water filtration system. This system was used to examine the efficiency of two ceramic filter discs as a medium for water filtration. These filters were made from two different ceramic mixtures of local red clay, sawdust, and water.  The filtration system was designed with two rotating interfered modules of these filters.  Rotating these modules generates shear force between water and the surfaces of filter discs of the filtration modules that works to reduce thickness of layer of rejected materials on the filters surfaces. Each module consists of seven filtration units and each unit consists of two ceramic filter discs.    The average measured hydraulic conductivity of the first module was 13.7mm/day and that for the second module was 50mm/day. Results showed that the water filtration system can be operated continuously with a constant flow rate and the filtration process was controlled by a skin thin layer of rejected materials. The ceramic water filters of both filtration modules have high removal efficiency of total suspended solids up to 100% and of turbidity up to 99.94%.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Sep 01 2021
Journal Name
Journal Of Engineering
Evaluation of Drinking Water Quality in Al Wahda Treatment Plant in Baghdad City- Iraq
...Show More Authors

This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Mar 27 2020
Journal Name
Iraqi Journal Of Science
Water Quality of Groundwater and Diyala River in Jisr Diyala Area within Baghdad City- Iraq
...Show More Authors

Groundwater is very important for different uses in the present study area which represents Jisr Diyala, located in southeastern Baghdad and covered with quaternary deposits which include the shallow aquifer in the area. Groundwater and surface water were investigated to determine their suitable uses. The main ion concentrations of the wet period seemed to be lower than those in the dry period. According to TDS values, the water is classified as brackish to salty with a high degree of hardness. Most of water samples were of NaCl type due to pollution with sewage water and rock-water interaction. The results show that the water of the study area is suitable for livestock and irrigation purposes only.

View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Iraqi Journal Of Science
Measurement of the radioactivity in raw materials used in the ceramic industry in AL-Ramadi ceramic factory using (HPGe) detector
...Show More Authors

In this research, we have measured specific activity concentrations in five samples for raw materials used in ceramic industry in AL-Ramadi ceramic factory by using (HPGe) detector. The results have shown that, the average specific activity, for 238U, 232Th and 40K are equal to (18.300±6.4 Bq/kg), (17.988±6.1 Bq/kg), (167.952±63.5 Bq/kg), respectively.  In order to assess the radiological hazards of the radioactivity in samples, radium equivalent activity, absorbed gamma dose rate, indoor and outdoor annual effective dose rates, gamma Index and both (external and internal) hazard effects have been calculated. All results were found to be less than the allowed global limit given by (UNSCEAR, 2000).

... Show More
View Publication Preview PDF
Publication Date
Thu Apr 12 2018
Journal Name
Lubricants
Importance of Emulsification in Calibrating Infrared Spectroscopes for Analyzing Water Contamination in Used or In-Service Engine Oil
...Show More Authors

View Publication
Scopus (13)
Crossref (10)
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Intelligent Systems And Applications In Engineering
Artificial Intelligence Based Statistical Process Control for Monitoring and Quality Control of Water Resources: A Complete Digital Solution
...Show More Authors

Scopus (3)
Scopus
Publication Date
Sun Jan 30 2022
Journal Name
Iraqi Journal Of Science
Optical Emission Spectroscopy for Studying Fe Plasma Parameters Produced by Exploding Wire Technique in Carbon Nanotubes - Water Colloid
...Show More Authors

     The goal of this work is to study plasma parameters for Fe plasma generated by exploding wire (EEW) in carbon nanotubes-water colloid with three current values (50, 100 and 150)A. In this research, the plasma electron temperature (Te), the electron density (ne), electron density (ne), plasma frequency(f p), Debye length (λD) and Debye number (ND) were  found for Fe produced by Arc discharge plasma. Boltzmann plot was used to calculate the plasma electron temperature (Te);electron density (ne) was calculated from  Stark broadening. It was found that the electron temperature values increased from (0.4

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Iraqi Journal Of Agricultural Sciences, 2018, 49(2), Pp. 179–187
Estimation of some genetic parameters for grain yield and its components of maize under watered and water stress
...Show More Authors

Scopus (7)
Scopus
Publication Date
Sun Jul 25 2021
Journal Name
Natural Resources Research
Effect of Water Flooding on Oil Reservoir Permeability: Saturation Index Prediction Model for Giant Oil Reservoirs, Southern Iraq
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Thu Dec 20 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
EVALUATION OF THE EFFICIENCY OF AL-WAHDA PLANT IN PURIFICATION OF POTABLE WATER: EVALUATION OF THE EFFICIENCY OF AL-WAHDA PLANT IN PURIFICATION OF POTABLE WATER
...Show More Authors

Water samples were collected from output of water for Al-Wahda plant where located in al-karrada area in Baghdad city to study water contamination with bacteria, fungi and Algae. The study lasted one year started on August, 2016 to July,2017.Results were acquired according to two tests performed, the first is biological test included total coliform,E.coli, pseudomonas aeruginosa, total fungi, Diatom and non Diatom Algae and the second is physiochemical test included temperature, turbidity and residual chlorine. The results of bacteria were within the permitted specification in the Iraqi standards no. 14/2270 for the year 2015 except August was exceeded the permitted standard for total coliform, it was 1.1< cell/100 ml.Total Fungi, Dia