Preferred Language
Articles
/
joe-481
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the reduction was an average (0.66 oC) when compared with the conventional wall .

 

View Publication
Publication Date
Sat Mar 28 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Different Electrodes Connections in Electrocoagulation of Synthetic Blow down Water of Cooling Tower
...Show More Authors

In this research, the performance of electrocoagulation (EC) using aluminum (Al) electrodes with   Monopolar- parallel (MP-P), and bipolar - series (BP-S) arrangement for simultaneous removal of dissolved silica, and hardness ions (calcium, and magnesium) from synthetic blowdown water of cooling tower were investigated. The effects of current density, initial pH and time of electrolysis on the removal efficiency were studied in a batch stirred unit to find out the best-operating conditions. The obtained results for each target species are evidence that BP-S approach is the best for both electrodes configuration operated at a Current density of 1mA/cm2 through 30 min of treatment and pH=10 with the removal of

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Asset Utilization Efficiency and its effect on the sustainable Stockholder’s Wealth: Apply Study of Iraqi Companies listed on the Iraqi Stock Exchange
...Show More Authors

The research discusses one of the most critical issues of corporate finance which is related to asset utilization efficiency. Researchers used internal growth rate as independent variable (Proxy of asset utilization efficiency) and sustainable growth rate-dependent variable (proxy of stockholders wealth). According to these two variables, researchers formulate major hypotheses (There is no significant effect of internal growth rate on sustainable growth rate), as well as two sub-hypotheses, examine the components of major variables. Sample of Iraqi industrial companies which listed in the Iraqi stock exchange selected to test and examine main hypotheses. Result of simple and multiple regressions explain there is a significant effect of i

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 23 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effect of pharmacist interventions on pulmonary function parameters of Iraqi asthmatic patients: A comparative study: Effect of pharmacist interventions on pulmonary functions tests
...Show More Authors

Background: Despite the fact that asthma is a long-term disease that may be treated, many people are unable to control their symptoms due to a lack of knowledge about their condition. The study's purpose was to find out if a pharmacist intervention improved asthma management because of this.

Objective: this study designed to assess the effect of pharmaceutical care on pulmonary functions test.

Method: The study was completed in three months. The patients who were enrolled were divided into two groups: Group 1 consists of 23 asthma patients who were randomly assigned to receive conventional therapy for chronic bronchial asthma based on disease stage and se

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 03 2015
Journal Name
Journal Of Engineering And Development
3D Presentation for Baghdad University Buildings Using Total Station Device
...Show More Authors

capable of the measuring with a high degree of precision in a single instrument. Total stations device are used for station setting up, setting-outmany points from one station. Their major purpose of this work is to take advantage of total station for setting up building and to establish 3D representation using AutoCAD program. The area of the study was Civil Engineering Department at Baghdad University campus AL Jadiriyah. The completion of the work is done in two stages; 1. The field work: In this stage, the Total Station Nikon Nivo-5C was selected for the current study. This device was measured horizontal and vertical distance, elevations, and coordinates from a single set up. This data directly stored on memory. 2. The office work: In t

... Show More
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Greening Existing Buildings in Contemporary Iraqi Urban Reality/ Virtual Model
...Show More Authors

The approach of greening existing buildings, is an urgent necessity, because the greening operation provides the speed and optimal efficiency in the environmental performance, as well as keeping up with the global green architecture revolution. Therefore, greening existing buildings in Iraq is important for trends towards renewable energies, because of what the country went through economic conditions and crises and wars which kept the country away from what took place globally in this issue. The research problem is: insufficient knowledge about the importance and the mechanism of the greening of existing buildings, including its environmental and economic dimensions, by rationalization of energy consumption and preservi

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
The Effect of Staggered porous fins on the performance of Photovoltaic panel in Baghdad
...Show More Authors

The performance of photovoltaic (PV) panel having staggered metal foam fins was examined experimentally in Baghdad, Iraq. Three staggered metal foam fin configurations attached to the backside of the PV panel were studied. The measured parameters were front and back surfaces temperature, open voltage and current circuits, maximum power, and PV efficiency. It was noted that the maximum electrical efficiency enhancement was 4.7% for staggered metal foam fins (case III) than the reference PV panel. The operating temperature of the cell was increased when the value of solar intensity was high. Thereby, the electrical efficiency was decreased. It was found that the metal foam fins decreased the PV temperature by 2-3 o

... Show More
View Publication Preview PDF
Crossref (17)
Crossref
Publication Date
Thu Oct 01 2020
Journal Name
International Communications In Heat And Mass Transfer
Thermal behaviour of the flow boiling of a complex nanofluid in a rectangular channel: An experimental and numerical study
...Show More Authors

View Publication
Scopus (33)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Tue Dec 15 2020
Journal Name
Al-academy
Formal Formation and its Semantic Projections in the Design Interior Spaces of the Daily newspapers Buildings: آراء عبد الكريم حسين
...Show More Authors

The research deals with the topic of (formal formation and its semantic projections in the design interior spaces of daily newspapers buildings) including the research problem summarized by the following question: (does the formal formation do a semantic role in the design of the interior spaces?). The research objective has been evident in discovering strong and weak points in the formal formations and their semantic projections in the design of the interior spaces for the daily newspapers buildings, reaching at the best design foundations, and shedding light on the cognitive and scientific importance of the research, and the objective, temporal and spatial limits in addition to identifying the terms. The theoretical framework includes

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Thu May 14 2020
Journal Name
Journal Of Planner And Development
“The role of parametric approach in design highest climatic performance buildings: local housing design patterns as a sample”
...Show More Authors

In light of increasing demand for energy consumption due to life complexity and its requirements, which reflected on architecture in type and size, Environmental challenges have emerged in the need to reduce emissions and power consumption within the construction sector. Which urged designers to improve the environmental performance of buildings by adopting new design approaches, Invest digital technology to facilitate design decision-making, in short time, effort and cost. Which doesn’t stop at the limits of acceptable efficiency, but extends to the level of (the highest performance), which doesn’t provide by traditional approaches that adopted by researchers and local institutions in their studies and architectural practices, limit

... Show More
View Publication Preview PDF