Preferred Language
Articles
/
joe-481
Experimental Study of the effect of closed cavity wall on buildings cooling loads saving
...Show More Authors

The experimental study showed the use of closed cavity wall (the thickness of the cavity 5cm) made a percentage reduction in the cooling load caused by heat gain from the wall by (21.5 %) compared with the conventional wall. also the thermal resistance of the closed cavity was an average (0.2 m2.oC/W).

The experimental results of the study showed that the use of closed cavity wall reduced the average temperature of the inner surface of the wall during the day, and that the reduction was an average (0.45 oC)  when compared with the conventional wall , as well as the use of closed cavity wall reduced the temperature difference range of the inner surface of the wall during the day, and that the reduction was an average (0.66 oC) when compared with the conventional wall .

 

View Publication
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Cavity preparation model in rat maxillary first molars: A pilot study
...Show More Authors

Objective: To conduct a standardized method for cavity preparation on the palatal surface of rat maxillary molars and to introduce a standardized method for tooth correct alignment within the specimen during the wax embedding procedure to better detect cavity position within the examined slides. Materials and methods: Six male Wistar rats, aged 4-6 weeks, were used. The maxillary molars of three animals were sectioned in the frontal plane to identify the thickness of hard tissue on the palatal surface of the first molar which was (250-300µm). The end-cutting bur (with a cutting head diameter of 0.2mm) was suitable for preparing a dentinal cavity (70-80µm) depth. Cavity preparation was then performed using the same bur on the tooth

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Cavity preparation model in rat maxillary first molars: A pilot study
...Show More Authors

Objective: To conduct a standardized method for cavity preparation on the palatal surface of rat maxillary molars and to introduce a standardized method for tooth correct alignment within the specimen during the wax embedding procedure to better detect cavity position within the examined slides. Materials and methods: Six male Wistar rats, aged 4-6 weeks, were used. The maxillary molars of three animals were sectioned in the frontal plane to identify the thickness of hard tissue on the palatal surface of the first molar which was (250-300µm). The end-cutting bur (with a cutting head diameter of 0.2mm) was suitable for preparing a dentinal cavity (70-80µm) depth. Cavity preparation was then performed using the same bur on the tooth surf

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Nov 01 2018
Journal Name
Computers & Fluids
Assessing moment-based boundary conditions for the lattice Boltzmann equation: A study of dipole-wall collisions
...Show More Authors

View Publication
Scopus (20)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Numerical and Experimental Investigations of the Effect of PVD and Vacuum Pressure on the Degree of Saturation
...Show More Authors

    Soft clays are generally characterized by low shear strength, low permeability and high compressibility. An effective method to accelerate consolidation of such soils is to use vertical drains along with vacuum preloading to encourage radial flow of water.  In this research numerical modeling of prefabricated vertical drains with vacuum pressure was done to investigate the effect of using vertical drains together with vacuum pressure on the degree of saturation of fully and saturated-unsaturated soft soils.  Laboratory experiments were conducted by using a specially-designed large consolidometer cell where a central drain was installed and vacuum pressure was applied. All tests were conducted

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 01 2021
Journal Name
Iop Conference Series: Materials Science And Engineering
Experimental Study on the Behaviours of Post-tensioned Concrete Members with Unbonded Tendons
...Show More Authors
Abstract<p>This paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength, <italic>f<sub>c</sub> </italic>′; jacking stress, <italic>f<sub>j</sub> </italic>; and the prestressing index, ω. Increasing the concrete compressive strength from 35 MPa to 60 MPa was seen to lead to an increase in load-carrying capacity by about 10%. The load capacity was also affected, though to a lesser extent, by the jacking stress. The failure lo</p> ... Show More
View Publication
Publication Date
Thu Aug 31 2017
Journal Name
Journal Of Engineering
The Effect of Cyclic Bending Loads on Crack Growth in Pipes for Inclined and Transverse Cracks with or Without Internal Pulsing Pressure
...Show More Authors

In the present research a new test rig has been proposed to be suitable for different cyclic loads such as cyclic bending, cyclic torsion, proportional and non proportional loads. In this work the efforts were concentrated on the cyclic bending loads concerning cracked pipes with or without internal pulsing pressure to study crack propagation in small bore pipes (up to 1'') for transverse or inclined cracks. The rig simulates the real service conditions under different stresses by means the least dangerous case will be suggested, so the experiments were considered for copper pipe, and the results have been tabulated and drawn to demonstrate the crack growth behavior as well as to justify the outcomes practically, consequently the durabil

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Aci Structural Journal
Experimental and Analytical Study on Punching Shear Strength of BubbleDecks
...Show More Authors

View Publication
Crossref (2)
Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Materials Today: Proceedings
An experimental study of the effects of matrix acidising on the petrophysical characteristics of carbonate formation
...Show More Authors

View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
The slenderness ratio effect on the response of closed-end pipe piles in liquefied and non-liquefied soil layers under coupled static-seismic loading
...Show More Authors
Abstract<p>This study presents the findings of a 3D finite element modeling on the performance of a single pile under various slenderness ratios (25, 50, 75, 100). These percentages were assigned to cover the most commonly configuration used in such kind of piles. The effect of the soil condition (dry and saturated) on the pile response was also investigated. The pile was modeled as a linear elastic, the surrounded dry soil layers were simulated by adopting a modified Mohr-Coulomb model, and the saturated soil layers were simulated by the modified UBCSAND model. The soil-pile interaction was represented by interface elements with a reduction factor (R) of 0.6 in the loose sand layer and 0.7 in t</p> ... Show More
Scopus (13)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Fri Oct 13 2023
Journal Name
Engineering, Technology &amp; Applied Science Research
The Experimental and Theoretical Effect of Fire on the Structural Behavior of Laced Reinforced Concrete Deep Beams
...Show More Authors

A Laced Reinforced Concrete (LRC) structural element comprises continuously inclined shear reinforcement in the form of lacing that connects the longitudinal reinforcements on both faces of the structural element. This study conducted a theoretical investigation of LRC deep beams to predict their behavior after exposure to fire and high temperatures. Four simply supported reinforced concrete beams of 1500 mm, 200 mm, and 240 mm length, width, and depth, respectively, were considered. The specimens were identical in terms of compressive strength (  40 MPa) and steel reinforcement details. The same laced steel reinforcement ratio of 0.0035 was used. Three specimens were burned at variable durations and steady-state temperatures (one

... Show More
View Publication
Scopus (6)
Crossref (4)