Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
...Show More Authors

This study concerns a new type of heat exchangers, which is that of shell-and-double concentric tube heat exchangers. The case studies include both design calculations and performance calculations.

       The new heat exchanger design was conducted according to Kern method. The volumetric flow rates were 3.6 m3/h and 7.63 m3/h for the hot oil and water respectively. The experimental parameters studied were: temperature, flow rate of hot oil, flow rate of cold water and pressure drop.

A comparison was made for the theoretical and experimental results and it was found that the percentage error for the hot oil outlet temperature was (- 1.6%). The percentage errors for the pressure drop in the shell and in the concentric tubes were (17.2%) and (- 39%) respectively. For cold water outlet temperature, the percentage error was (- 3.3%), while it was (18%) considering the pressure drop in the annulus formed. The percentage error for the total power consumed was (-10.8%).

A theoretical comparison was made between the new design and the conventional heat exchanger from the point of view of, length, mass, pressure drop and total power consumed.

 

 

View Publication
Publication Date
Mon Mar 15 2021
Journal Name
Energies
Intensifying the Charging Response of a Phase-Change Material with Twisted Fin Arrays in a Shell-And-Tube Storage System
...Show More Authors

A twisted-fin array as an innovative structure for intensifying the charging response of a phase-change material (PCM) within a shell-and-tube storage system is introduced in this work. A three-dimensional model describing the thermal management with charging phase change process in PCM was developed and numerically analyzed by the enthalpy-porosity method using commercial CFD software. Efficacy of the proposed structure of fins for performing better heat communication between the active heating surface and the adjacent layers of PCM was verified via comparing with conventional longitudinal fins within the same design limitations of fin material and volume usage. Optimization of the fin geometric parameters including the pitch, numb

... Show More
View Publication Preview PDF
Scopus (45)
Crossref (43)
Scopus Clarivate Crossref
Publication Date
Tue Jul 21 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Numerical Study of the Heat Transfer Behavior in Helical Microcoil Tube
...Show More Authors

View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Sep 02 2023
Journal Name
Al-khwarizmi Engineering Journal (alkej)
Numerical Investigations on Heat Flow of Nanofluids in Ribs Tube Configurations
...Show More Authors

Publication Date
Sat Mar 30 2013
Journal Name
Australian Journal Of Basic And Applied Sciences
CFD Simulation of Heat Transfer Augmentation in Constant Heat-Fluxed Tube fitted with Baffled Twisted Tape Inserts
...Show More Authors

Publication Date
Wed Sep 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Prediction of the Scale Removal Rate in Heat Exchanger Piping System Using the Analogies between Mass and Momentum Transfer
...Show More Authors

The possibility of predicting the mass transfer controlled CaCO3 scale removal   rate has been investigated.

Experiments were carried out using chelating agents as a cleaning solution at different time and Reynolds’s number. The results of CaCO3 scale removal or (mass transfer rate) (as it is the controlling process) are compared with proposed model of prandtl’s and Taylor particularly based on the concept of analogy among momentum and mass transfer.

Correlation for the variation of Sherwood number ( or mass transfer rate ) with Reynolds’s number have been obtained .

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Energy Conversion And Management
Improved PCM melting in a thermal energy storage system of double-pipe helical-coil tube
...Show More Authors

View Publication
Scopus (116)
Crossref (109)
Scopus Clarivate Crossref
Publication Date
Tue Jul 01 2014
Journal Name
Journal Of The Faculty Of Medicine Baghdad
The incidence of hypoxemia due to malposition of double lumen endotracheal tube during one lung ventilation
...Show More Authors

Background: Oxygenation during one lung ventilation (OLV) can be affected by positioning of Double lumen endobronchial tube (DLT). Mal position can occurs following intubation and moving the patient to the lateral decubitus position.

Objectives: To study the relation of hypoxemia to mal position of double lumen endo bronchial  tube after patient positioning in lateral decubitus position and during one lung ventilation. The use of fiber-optic

Fac Med Baghdad

2014; Vol.56, No.2

Received: Jan., 2014

Accepted March. 2014

 

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Numerical Analysis of Double Diffusive Laminar Natural Convection in a Right Angle Triangular Solar Collector
...Show More Authors

A numerical study of the double-diffusive laminar natural convection in a right triangular solar collector has been investigated in present work. The base (absorber) and glass cover of the collector are isothermal and isoconcentration surfaces, while the vertical wall is considered adiabatic and impermeable. Both aiding and opposing buoyancy forces have been studied. Governing equations in vorticity-stream function form are discretized via finite-difference method and are solved numerically by iterative successive under relaxation (SUR) technique. Computer code for MATLAB software has been developed and written to solve mathematical model. Results in the form of streamlines, isotherms, isoconcentration, average Nusselt, and average Sherw

... Show More
View Publication Preview PDF
Publication Date
Thu Jul 01 2021
Journal Name
Iraqi Journal Of Science
Simultaneous Identification of Thermal Conductivity and Heat Source in the Heat Equation
...Show More Authors

This paper presents a numerical solution to the inverse problem consisting of recovering time-dependent thermal conductivity and  heat source coefficients  in the one-dimensional  parabolic heat equation.   This  mathematical  formulation  ensures that the inverse problem  has a unique  solution.   However, the problem  is still  ill-posed since small errors  in the input data lead to a drastic  amount  of errors in the output coefficients.  The  finite  difference method  with  the Crank-Nicolson  scheme is adopted  as a direct  solver of the problem in a fixed domain.   The inverse problem is solved sub

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (3)
Scopus Crossref
Publication Date
Mon Nov 22 2021
Journal Name
Nanomaterials
Melting Enhancement in a Triple-Tube Latent Heat Storage System with Sloped Fins
...Show More Authors

Due to the potential cost saving and minimal temperature stratification, the energy storage based on phase-change materials (PCMs) can be a reliable approach for decoupling energy demand from immediate supply availability. However, due to their high heat resistance, these materials necessitate the introduction of enhancing additives, such as expanded surfaces and fins, to enable their deployment in more widespread thermal and energy storage applications. This study reports on how circular fins with staggered distribution and variable orientations can be employed for addressing the low thermal response rates in a PCM (Paraffin RT-35) triple-tube heat exchanger consisting of two heat-transfer fluids flow in opposites directions throug

... Show More
View Publication
Scopus (33)
Crossref (31)
Scopus Clarivate Crossref