Preferred Language
Articles
/
joe-453
Finite Element Investigation on Shear Lag in Composite Concrete-Steel Beams with Web Openings
...Show More Authors

In this paper, effective slab width for the composite beams is investigated with special emphasis on the effect of web openings. A three dimensional finite element analysis, by using finite element code ANSYS, is employed to investigate shear lag phenomenon and the resulting effective slab width adopted in the classical T-beam approach. According to case studies and comparison with limitations and rules stipulated by different standards and codes of practice it is found that web openings presence and panel proportion are the most critical factors affecting effective slab width, whereas concrete slab thickness and steel beam depth are less significant. The presence of web opening reduces effective slab width by about 21%. Concentrated load produces smaller effective slab width when compared with uniformly distributed and line loads. Generally, standard codes of practice overestimate effective slab width for concentrated load effect, while underestimate effective slab width for uniformly distributed and line load effect. Based on the data available, sets of empirical equations are developed to estimate the effective slab width in the composite beams with web openings to be used in the classical T-beam approach taking into account the key parameters investigated.   

  

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue May 16 2023
Journal Name
Journal Of Engineering
FREE VIBRATION ANALYSIS OF COMPOSITE LAMINATED PLATES USING HOST 12
...Show More Authors

This paper presents an application of a Higher Order Shear Deformation Theory (HOST 12) to problem
of free vibration of simply supported symmetric and antisymmetric angle-ply composite laminated plates.
The theoretical model HOST12 presented incorporates laminate deformations which account for the effects
of transverse shear deformation, transverse normal strain/stress and a nonlinear variation of in-plane
displacements with respect to the thickness coordinate – thus modeling the warping of transverse crosssections more accurately and eliminating the need for shear correction coefficients. Solutions are obtained in
closed-form using Navier’s technique by solving the eigenvalue equation. Plates with varying number of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Common Fixed Point of a Finite-step Iteration Algorithm Under Total Asymptotically Quasi-nonexpansive Maps
...Show More Authors

      Throughout this paper, a generic iteration algorithm for a finite family of total asymptotically quasi-nonexpansive maps in uniformly convex Banach space is suggested. As well as weak / strong convergence theorems of this algorithm to a common fixed point are established. Finally, illustrative numerical example by using Matlab is presented.

View Publication Preview PDF
Scopus (15)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Diyala Journal Of Human Research
Stability of the Finite Difference Methods of Fractional Partial Differential Equations Using Fourier Series Approach
...Show More Authors

The fractional order partial differential equations (FPDEs) are generalizations of classical partial differential equations (PDEs). In this paper we examine the stability of the explicit and implicit finite difference methods to solve the initial-boundary value problem of the hyperbolic for one-sided and two sided fractional order partial differential equations (FPDEs). The stability (and convergence) result of this problem is discussed by using the Fourier series method (Von Neumanns Method).

View Publication Preview PDF
Publication Date
Sat Feb 11 2023
Journal Name
Applied Sciences
A Preliminary Study and Implementing Algorithm Using Finite State Automaton for Remote Identification of Drones
...Show More Authors

Electronic remote identification (ER-ID) is a new radio frequency (RF) technology that is initiated by the Federal Aviation Authorities (FAA). For security reasons, traffic control, and so on, ER-ID has been applied for drones by the FAA to enable them to transmit their unique identification and location so that unauthorized drones can be identified. The current limitation of the existing ER-ID algorithms is that the application is limited to the Wi-Fi and Bluetooth wireless controllers, which results in a maximum range of 10–20 m for Bluetooth and 50–100 m for Wi-Fi. In this study, a mathematical computing technique based on finite state automaton (FSA) is introduced to expand the range of the ER-ID RF system and reduce the ene

... Show More
View Publication
Scopus (5)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Mechanical Science And Technology
Damage detection in glass/epoxy composite structure using 8–12 GHz X-band
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Sep 29 2024
Journal Name
International Journal Of Corrosion And Scale Inhibition
Using expired pharmaceutical Clotrimazole as a corrosion inhibitor for stainless steel in acidic media
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Indole derivatives efficacy and kinetics for inhibiting carbon steel corrosion in sulfuric acid media
...Show More Authors

View Publication
Scopus (22)
Crossref (19)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Anti-Corrosive Substance as Green Inhibitor for Carbon Steel in Saline and Acidic Media
...Show More Authors

Ficus (FIC) leaf extract used as corrosion inhibitor for carbon steel alloy (C.S) in two corrosive environments (saline and acidic) with four concentrations (1, 2, 3 and 4 ppm) at varied temperature range between (298-328 K) using electrochemical polarization measurements. The importance of this work focused on the use the green chemistry that is far from the chemical materials effect. The results of polarization presented the FIC inhibitor consider a mixed type (anodic and cathodic) inhibitor. Tafel curve used to evaluate the corrosion inhibition activity. In a saline medium, the best inhibitor efficiency reaches to (87%) in 2 ppm and IE% reach to (99%) for HCl medium inhibited by 1ppm. Langmuir isotherm obeys the study by thermodynamic pa

... Show More
View Publication
Scopus (30)
Crossref (17)
Scopus Crossref
Publication Date
Mon Jun 27 2022
Journal Name
Sustainability
Thermal Properties of Hydrated Lime-Modified Asphalt Concrete and Modelling Evaluation for Their Effect on the Constructed Pavements in Service
...Show More Authors

Flexible pavements are subjected to three main distress types: fatigue crack, thermal crack, and permanent deformation. Under severe climate conditions, thermal cracking particularly contributes largely to a considerable scale of premature deterioration of pavement infrastructure worldwide. This challenge is especially relevant for Europe, as weather conditions vary significantly throughout the year. Hydrated lime (HL) has been recognized as an effective additive to improve the mechanical properties of asphalt concrete for pavement applications. Previous research has found that a replacement of conventional limestone dust filler using hydrated lime at 2.5% of the total weight of aggregates generated an optimum improvement in the mec

... Show More
View Publication
Scopus (11)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Iop Conference Series: Earth And Environmental Science
Investigation of several heavy metals in Al-Saddah agricultural drainage in Hilla city /Iraq
...Show More Authors
Abstract<p>This study was done to determine the concentration of several heavy metals in the water of Al-Saddah agricultural drainage in Al-Saddah District in Babylon Province/Iraq. The concentrations of six heavy metals were measured (Pb, Cd, Cu, Hg, Fe, Zn). It was found that Pb concentration ranged from 0.06 mg/L at St.2 in autumn to 0.13 mg/L at St.2 in winter. Fe concentrations ranged from 0.04 mg/L at St.2 in autumn and winter to 0.41 at St.2 in Summer. Cd concentrations ranged from 0.008 mg/L at St.2 in summer to 0.05 mg/L at St.2 in winter. Cu concentrations ranged from 0.01 mg/L at St.1 in both autumn and winter to 0.63 mg/L at St.2 in winter. Hg concentrations was ranged from 0.002 mg/</p> ... Show More
View Publication
Scopus Crossref