Preferred Language
Articles
/
joe-436
On Gradient Descent Localization in 3-D Wireless Sensor Networks
...Show More Authors

Localization is an essential demand in wireless sensor networks (WSNs). It relies on several types of measurements. This paper focuses on positioning in 3-D space using time-of-arrival- (TOA-) based distance measurements between the target node and a number of anchor nodes. Central localization is assumed and either RF, acoustic or UWB signals are used for distance measurements. This problem is treated by using iterative gradient descent (GD), and an iterative GD-based algorithm for localization of moving sensors in a WSN has been proposed. To localize a node in 3-D space, at least four anchors are needed. In this work, however, five anchors are used to get better accuracy. In GD localization of a moving sensor, the algorithm can get trapped in a local minimum causing the track to deviate from the true path, thereby impairing real-time localization. The proposed algorithm is based on systematically replacing anchor nodes to avoid local minima positions. The idea is to form all possible combinations of five-anchor sets from a set of available anchor nodes (larger than five), and to segment the true path. Iterating through each segment, the sets of anchors that could draw the track to a local minimum are discarded and replaced with possible others to maintain the right track.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Polluted Water Sensor Based on Carbon Quantum Dots/Alq3 Using Drop Casting and Spin Coating Techniques
...Show More Authors

Water quality sensors have recently received a lot of attention due to their impact on human health. Due to their distinct features, environmental sensors are based on carbon quantum dots (CQDs). In this study, CQDs were prepared using the electro-chemical method, where the structural and optical properties were studied. These quantum dots were used in the environmental sensor application after mixing them with three different materials: CQDs, Alq3 polymer and CQDs and Alq3 solutions using two different methods: drop casting and spin coating, and depositing them on silicon. The sensitivity of the water pollutants was studied for each case of the prepared samples after measuring the change in resistance of the samples at a temperature of

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Feb 06 2023
Journal Name
Journal Of Kufa-physics
No-Core optical fibers sensor for detecting hemoglobin concentration (HB) based on the Surface Plasmon resonance.
...Show More Authors

In this work, a fiber-optic biomedical sensor was manufactured to detect hemoglobin percentages in the blood. SPR-based coreless optical fibers were developed and implemented using single and multiple optical fibers. It was also used to calculate refractive indices and concentrations of hemoglobin in blood samples. An optical fiber, with a thickness of 40 nanometers, was deposited on gold metal for the sensing area to increase the sensitivity of the sensor. The optical fiber used in this work has a diameter of 125μm, no core, and is made up of a pure silica glass rod and an acrylate coating. The length of the fiber was 4cm removed buffer and the splicing process was done. It is found in practice that when the sensitive refractive i

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Sep 25 2022
Journal Name
Research Journal Of Biotechnology
Evaluation of Interlukein-6 and Vitamin D in Patients with COVID-19
...Show More Authors

COVID-19 is a unique viral infectious illness that causes a variety of symptoms and health hazards, particularly to the respiratory system and has been declared a worldwide pandemic. The disease is characterized by a cytokine release in severe conditions. Interleukin-6 (IL-6), a proinflammatory cytokine, mediates an important immunomodulatory process. Also, vitamin D was identified to have a role in the innate immunity of individuals. Our study was designed to find the role of IL-6 and vitamin D in COVID-19 patients, as well as, to see whether there is a link between vitamin D deficiency and cytokine syndrome development. The study included 90 COVID-19 patients and 30 control people from Baghdad, Iraq. The age of the participants was non-s

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Evaluation of D-Dimer in the diagnosis of suspected deep vein thrombosis
...Show More Authors

Background: Deep vein thrombosis is a multi causal disease and its one of most common venous disorder, but only one quarter of the patients who have signs and symptoms of a clot in the vein actually have thrombosis and need treatment .The disease can be difficult to diagnose. Venous ultrasound in combination with clinical finding is accurate for venous thromboembolism, its costly because a large number of patients with suspicious signs and symptoms. Venography still the gold standard for venous thromboembolism but it is invasive. The D-dimer increasingly is being seen as valuable tool rolling out venous thromboembolism and sparing low risk patients for further workup.Objectives: this study has designed the role of D-dimer to confirm diag

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
A Fixed Point Theorem for L-Contraction in Generalized D-Metric Spaces
...Show More Authors

We define L-contraction mapping in the setting of D-metric spaces analogous to L-contraction mappings [1] in complete metric spaces. Also, give a definition for general D- matric spaces.And then prove the existence of fixed point for more general class of mappings in generalized D-metric spaces.

View Publication Preview PDF
Crossref
Publication Date
Sat Dec 01 2018
Journal Name
Annals Of Medicine And Surgery
Plasma d-dimer level correlated with advanced breast carcinoma in female patients
...Show More Authors

View Publication
Scopus (12)
Crossref (13)
Scopus Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Optical Fiber Technology
A taper-in-etch based hybrid fiber Mach-Zehnder interferometer hydrogen sensor
...Show More Authors

View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Fabrication and characterization of porous silicon for humidity sensor application
...Show More Authors

Porous Silicon (PS) layer has been prepared from p-type silicon by electrochemical etching method. The morphology properties of PS samples that prepared with different current density has been study using atom force measurement (AFM) and it show that the Layer of pore has sponge like stricture and the average pore diameter of PS layer increase with etching current density increase .The x-ray diffraction (XRD) pattern indicated the nanocrystaline of the sample. Reflectivity of the sample surface is decrease when etching current density increases because of porosity increase on surface of sample. The photolumenses (PL) intensity increase with increase etching current density. The PL is affected by relative humidity (RH) level so we can use

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Aug 03 2025
Journal Name
Journal Of Molecular Structure
Synergistic design of carbazole-bearing (D–π)₂-D–π–A architectures for dye-sensitized solar cells: Experimental and theoretical evaluations
...Show More Authors

Publication Date
Mon Feb 01 2016
Journal Name
Journal Of Engineering
Impact of Different H/D Ratio on Axial Gas Holdup Measured by Four-Tips Optical Fiber Probe in Slurry Bubble Column
...Show More Authors

In wide range of chemical, petrochemical and energy processes, it is not possible to manage without slurry bubble column reactors. In this investigation, time average local gas holdup was recorded for three different height to diameter (H/D) ratios 3, 4 and 5 in 18" diameter slurry bubble column. Air-water-glass beads system was used with superficial velocity up to 0.24 m/s. the gas holdup was measured using 4-tips optical fiber probe technique. The results show that the axial gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters larger than

... Show More
View Publication Preview PDF