A load-shedding controller suitable for small to medium size loads is designed and implemented based on preprogrammed priorities and power consumption for individual loads. The main controller decides if a particular load can be switched ON or not according to the amount of available power generation, load consumption and loads priorities. When themaximum allowed power consumption is reached and the user want to deliver power to additional load, the controller will decide if this particular load should be denied receiving power if its priority is low. Otherwise, it can be granted to receive power if its priority is high and in this case lower priority loads are automatically switched OFF in order not to overload the power generation. The main idea of the proposed LS controller is to minimize the amount of the isolated load without overloading the power system. In this paper, three versions of load shedding controller were implemented using Altera DE2-115 FPGA; with number of loads equal 32, 64 and 128 for each controller.
BACKGROUND: Polycystic ovary syndrome(PCOS) is one of the most common endocrine disorder affecting women in reproductive age. No single etiologic factor fully accounts for the spectrum of abnormalities in the polycystic ovary syndrome. Different changes in hormonal, metabolism and the inflammatory markers as squealy of PCOS with adverse effect on the women life. OBJECTIVE: To study the relationship between polycystic ovary syndrome and levels of C-reactive protein, human interleukin and hormonal and metabolic alteration in women with PCOS PATIENTS AND METHODS: Thirty women with Polycystic Ovary syndrome (PCOS) and other thirty women without PCOS were included. Venous blood samples were taken in early follicular phase of menstrual cycle [day
... Show MoreIn this paper, variable gain nonlinear PD and PI fuzzy logic controllers are designed and the effect of the variable gain characteristic of these controllers is analyzed to show its contribution in enhancing the performance of the closed loop system over a conventional linear PID controller. Simulation results and time domain performance characteristics show how these fuzzy controllers outperform the conventional PID controller when used to control a nonlinear plant and a plant that has time delay.
Social risks posed a great challenge to the development path in Iraq, which resulted in widening the development gaps, whether these gaps were between rural and embargoed areas, or between Iraqi governorates, and the gender gap. Besides, the nature of the reciprocal relationship between the social risks and the development process requires the adoption of development trends that are sensitive to the risks that take upon themselves the prompt and correct response to these risks, away from randomness and confusion that Iraq suffered from for decades. However, currently, the situation has differed a great deal. This is because the size and types of such gaps have widened and become more complicated than before; a matter which has led to hav
... Show MoreLinear motor offers several features in many applications that require linear motion. Nevertheless, the presence of cogging force can deteriorate the thrust of a permanent magnet linear motor. Using several methodologies, a design of synchronous single sided linear iron-core motor was proposed. According to exact formulas with surface-mounted magnets and concentrated winding specification, which are relying on geometrical parameters. Two-dimensional performance analysis of the designed model and its multi-objective optimization were accomplished as a method to reduce the motor cogging force using MAXWELL ANSYS. The optimum model design results showed that the maximum force ripple was approximatrly reduced by 81.24%compared to the origina
... Show MoreBackground: Bacteriocin is a peptidic toxin has many advantages to bacteria in their ecological niche and has strong antibacterial activity. Objective: The aim of this study was to evaluation of bacteriocin using Streptococcus sanguinis isolated from human dental caries.
Subjects and Methods: Thirty five streptococcus isolates were diagnosed and tested for their production of bacteriocin, and then the optimal conditions for production of bacteriocin were determined. After that, the purification of bacteriocin was made partially by ammonium sulfate at 95% saturation levels, followed by and gel filtration chromatography
... Show More