Preferred Language
Articles
/
joe-378
An Investigation into Thermal Performance of Closed Wet Cooling Tower for Use with Chilled Ceilings in Buildings
...Show More Authors

Chilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects on the ICCCCT characteristics such as tower cooling capacity, chilled ceiling cooling capacity, tower saturation efficiency, mass transfer coefficient and heat transfer coefficient. The following controlling parameters are varied during experiments: spray water flow rate (90 to 150 kg/hr), ambient air wet bulb temperature (12 to 18 oC), and also changing chilled ceiling flow rate (2 to 6 l/min).

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 30 2012
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Polyvinyl Alcohol – Sodium Nitrite Water Soluble Composite as a Corrosion Inhibitor for Mild Steel in Simulated Cooling Water
...Show More Authors

The inhibitive action of polyvinyl alcohol –sodium nitrite (PVASN) composite on the corrosion of mild steel in simulated cooling water (SCW) has been investigated by weight loss and potentiodynamic polarization. The effect of composite concentration (PVA/SN) , pH, and exposure time on corrosion rate of mild steel were verified using 2 levels factorial design and surface response analysis through weight loss approach, while the electrochemical measurements were used to study the behavior of mild steel in (SCW) with pH between 6 and 8 and in absence and presence of (PVA) in solution containing different concentration of NaNO2. It was verified that all three main variables studied were statistically significant while their interaction is

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 15 2020
Journal Name
Al-academy
Recycling evening dresses into modern dresses with traditional features: ليلى عبد الغفار فدا
...Show More Authors

  This research aims to harmonize contemporary and traditional clothes, also expenses and savings. It is done by recycling evening clothes into Clothes with traditional features. The study followed descriptive explanatory approach. The sample consisted of seven dresses, as well as 208 female participants from Makkah Al-Mukarramah province, the age range was between 21 and 65 years old. An electronic questionnaire was distributed and the stability and reliability of the internal consistency were measured.
The research resulted in the ability to recycle evening dresses into modern clothes with traditional characteristics. It also confirmed that the reason of wearing traditional clothes is spirituality of the month of Ramadan. Addi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Swinburne University Of Technology
Numerical Modeling of Flow through Foam Nodes in the Presence of Solid Particles for Foams within the Dry Limit and for Foams that are Approaching the Wet Limit
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Modeling and Simulation of Thermal Performance of Solar-Assisted Air Conditioning System under Iraq Climate
...Show More Authors

In Iraq most of the small buildings deployed a conventional air conditioning technology which typically uses electrically driven compressor systems which exhibits several clear disadvantages such as high energy consumption, high electricity at peak loads. In this work a thermal performance of air conditioning system combined with a solar collector is investigated theoretically. The hybrid air conditioner consists of a semi hermetic compressor, water cooled shell and tube condenser, thermal expansion valve and coil with tank evaporator. The theoretical analysis included a simulation for the solar assisted air-conditioning system using EES software to analyze the effect of different parameters on the power consumption of c

... Show More
View Publication Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
The Journal Of Engineering Research [tjer]
Thermal Performance of Solar Hot Water Systems Using a Flat Plate Collector of Accelerated Risers
...Show More Authors

 This study focuses on a comparison of the performance of two similar locally-fabricated solar water heaters. One of the collectors features a new design for accelerated absorber; its risers are made of converging ducts whose exit area is half that of the entrance. The other collector is a conventional absorber, with risers of the same cross sectional area along its length. Each collector is the primary part of an indirect thermosyphon circulation solar hot water system. Both collectors face south with a fixed tilt angle of 33.3

View Publication
Scopus (11)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Heat Transfer
Effect of receiver geometry on the optical and thermal performance of a parabolic trough collector
...Show More Authors
Abstract<p>In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical </p> ... Show More
View Publication
Scopus (20)
Crossref (15)
Scopus Crossref
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of Internal Medicine
On the use of substandard medicines in hematology: An emerging concern in the Middle East and North Africa region
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Corrosion behavior of mild-steel in cooling towers using high salinity solution
...Show More Authors

Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in t

... Show More
View Publication
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Evaluate the performance of horizontal flow wetlands as an option for tertiary treatment of secondary sedimentation basins
...Show More Authors
Abstract<p>Constructed wetlands (CWs) are simple low-cost wastewater treatment units that use natural process to improve the effluent water quality and make it possible for its reuse.in this study used the horizontal flow system for the tertiary treatment of wastewater effluent from secondary basins at Al-Rustamiya wastewater treatment plant / old project / Baghdad / Iraq. the Phragmites Australis plant was used for wastewater treatment and the horizontal subsurface flow system was applied. the experimental study was carried out in February 2020 to October 2020. the parameters were monitored for a period of five weeks, Concentration-based average removal efficiencies for HSSF-CW were COD,53% [NO</p> ... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
The Investigation of Monitoring Systems for SMAW Processes
...Show More Authors

The monitoring weld quality is increasingly important because great financial savings are possible because of it, and this especially happens in manufacturing where defective welds lead to losses in production and necessitate time consuming and expensive repair. This research deals with the monitoring and controllability of the fusion arc welding process using Artificial Neural Network (ANN) model. The effect of weld parameters on the weld quality was studied by implementing the experimental results obtained from welding a non-Galvanized steel plate ASTM BN 1323 of 6 mm thickness in different weld parameters (current, voltage, and travel speed) monitored by electronic systems that are followed by destructive (Tensile and Bending) and non

... Show More
View Publication Preview PDF