Preferred Language
Articles
/
joe-378
An Investigation into Thermal Performance of Closed Wet Cooling Tower for Use with Chilled Ceilings in Buildings
...Show More Authors

Chilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects on the ICCCCT characteristics such as tower cooling capacity, chilled ceiling cooling capacity, tower saturation efficiency, mass transfer coefficient and heat transfer coefficient. The following controlling parameters are varied during experiments: spray water flow rate (90 to 150 kg/hr), ambient air wet bulb temperature (12 to 18 oC), and also changing chilled ceiling flow rate (2 to 6 l/min).

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
International Journal Of Hydrogen Energy
A comprehensive review of battery thermal management systems for electric vehicles: Enhancing performance, sustainability, and future trends
...Show More Authors

View Publication
Scopus (17)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Use of Coliphages as an indicators of enteroviruses and faecal pollution in Water
...Show More Authors

In spite of increasing clinical cases which caused by enteroviruses transferred by water and no documents about entericviruses in the Iraqi water standards. The use of coliphages as an indicator of enteroviruses and fecal pollution were suggested two procedures were applied . The first is Two-Step Enrichment Method and the second is Single Agar Layer Method. Both methods gives good results in Identification of coliphages through testing fifty different water samples (Tap water, Surface water and Bottled water) the study shows the presence of coliphages in fourteen samples.

View Publication Preview PDF
Crossref
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Analysis and Optimum Design of Self Supporting Steel Communication Tower
...Show More Authors

The present study deals with the optimum design of self supporting steel communication towers. A special technique is used to represent the tower as an equivalent hollow tapered beam with variable cross section. Then this method is employed to find the best layout of the tower among prespecified configurations. The formulation of the problem is applied to four types of tower layout
with K and X brace, with equal and unequal panels. The objective function is the total weight of the tower. The variables are the base and the top dimensions, the number of panels for the tower and member's cross section areas. The formulations of design constraints are based on the requirements of EIA and ANSI codes for allowable stresses in the members

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 03 2013
Journal Name
Al-kindy College Medical Journal
Conservative Treatment of Closed Fracture Shaft Humerus in Adult Patients
...Show More Authors

Background: Fractures of the humeral shaft accounting for approximately 3% of all fractures. There is a wide array of good options for their treatment and controversy over the best methods. Although good techniques of osteosynthesis are available, the aim of this article is toemphasize on the benefit and good outcome of conservative treatment for properly selected cases to decrease the cost and avoid the complications of surgery. Method : During the period from February 2011 to June 2012 fifty-five fractures of humeral shaft were treated at orthopedicdepartment in the ALKindyteaching hospital. 22 fractures considered suitable for the study. The patients treatedconservatively by using the‘U’ shaped coaptation slab. Then we shift to POP c

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 30 2013
Journal Name
Al-kindy College Medical Journal
Conservative Treatment of Closed Fracture Shaft Humerus in Adult Patients
...Show More Authors

Background: Fractures of the humeral shaft
accounting for approximately 3% of all
fractures. There is a wide array of good
options for their treatment and controversy
over the best methods. Although good
techniques of osteosynthesis are available, the
aim of this article is toemphasize on the benefit
and good outcome of conservative treatment
for properly selected cases to decrease the cost
and avoid the complications of surgery.

View Publication Preview PDF
Publication Date
Sun Dec 30 2012
Journal Name
Al-kindy College Medical Journal
Evaluation of Management of Closed Spinal Injury
...Show More Authors

Objectives: to evaluate the role of conservative, decompression, spine fixation in management of closed spinal injury.
Methods: The study was conducted at Specialized Surgical hospital and Al-Kadhemayia Teaching Hospital, in the period between July 2003 and July 2005.The study included 61 patients categorized Into many groups according level of vertebral injury (cervical, cervicodorsal, dorsal, dorsolumbar, Lumbar and lumbosacral), type of injury (compressed fracture, burst fracture and fracture dislocation) And according the severity into three groups as G1( complete motor paralysis and sensory loss ) G2 ( complete motor paralysis and incomplete sensory loss) and G3 ( incomplete motor paralysis And incomplete sensory loss ).The metho

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 29 2024
Journal Name
International Journal Of Design & Nature And Ecodynamics
Artificial Neural Network Assessment of Groundwater Quality for Agricultural Use in Babylon City: An Evaluation of Salinity and Ionic Composition
...Show More Authors

View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Numerical Study Of Heat Transfer In Cooling Passages Of Turbine Blade
...Show More Authors

As the temperature of combustion gases is higher than the melting temperature of the turbine materials, cooling of turbine parts in a gas turbine engine is necessary for safe operation. Cooling methods investigated in this computational study included cooling flow losses. Film-cooling is one typically used cooling method whereby coolant is supplied through holes passage, in present study the holes placed along the camber line of the blade. The subject of this paper is to evaluate the heat transfer that occur on the holes of blade through different
blowing coolant rates. The cases of this study were performed in a low speed wind tunnel with two tip gap at small and large (0.03 and 0.09cm) and multiple coolant flow rates through the fil

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 28 2015
Journal Name
Al-khwarizmi Engineering Journal
Thermal Field Analysis of Oblique Machining Process with Infrared Image for AA6063-T6
...Show More Authors

Abstract

 Metal cutting processes still represent the largest class of manufacturing operations. Turning is the most commonly employed material removal process. This research focuses on analysis of the thermal field of the oblique machining process. Finite element method (FEM) software DEFORM 3D V10.2 was used together with experimental work carried out using infrared image equipment, which include both hardware and software simulations. The thermal experiments are conducted with AA6063-T6, using different tool obliquity, cutting speeds and feed rates. The results show that the temperature relatively decreased when tool obliquity increases at different cutting speeds and feed rates, also it

... Show More
View Publication Preview PDF