Preferred Language
Articles
/
joe-378
An Investigation into Thermal Performance of Closed Wet Cooling Tower for Use with Chilled Ceilings in Buildings
...Show More Authors

Chilled ceilings systems offer potential for overall capital savings. The main aim of the present research is to investigate the thermal performance of the indirect contact closed circuit cooling tower, ICCCCT used with chilled ceiling, to gain a deeper knowledge in this important field of engineering which has been traditionally used in various industrial & HVAC systems. To achieve this study, experimental work were implemented for the ICCCCT use with chilled ceiling. In this study the thermal performances of closed wet cooling tower use with chilled ceiling is experimentally and theoretically investigated. Different experimental tests were conducted by varying the controlling parameters to investigate their effects on the ICCCCT characteristics such as tower cooling capacity, chilled ceiling cooling capacity, tower saturation efficiency, mass transfer coefficient and heat transfer coefficient. The following controlling parameters are varied during experiments: spray water flow rate (90 to 150 kg/hr), ambient air wet bulb temperature (12 to 18 oC), and also changing chilled ceiling flow rate (2 to 6 l/min).

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 01 2020
Journal Name
International Journal Of Psychosocial Rehabilitation
Relationship of some fitness elements with the performance of lifting the iron ball (weight) by gliding method
...Show More Authors

AS Muhsen, International Journal of Psychosocial Rehabilitation (1475-7192), 2020 - Cited by 1

View Publication
Publication Date
Fri Jan 02 2026
Journal Name
The Iraqi Journal For Information And Documentation Studies
The role of performance indicators in evaluating the performance of the University of Technology's Central Library
...Show More Authors

University libraries seek to evaluate their performance in order to correct their path and adjust it in the right direction. Therefore, they use (performance indicators), which are a tool used by institutions to evaluate the weaknesses and strengths in their work and the reasons for failure to achieve some goals sometimes. They convert (goals, procedures and actions) into a formula that can be measured mathematically, which contributes to the library determining the gap between its current performance and what those libraries are supposed to be on, clarifying the path that the library is following, controlling the risks that may befall it, and thus enhancing the process of continuous improvement to avoid areas of failure and weakness becaus

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Ndt & E International
Porosity evaluation of in-service thermal barrier coated turbine blades using a microwave nondestructive technique
...Show More Authors

View Publication
Scopus (20)
Crossref (21)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Energy Conversion And Management
Improved PCM melting in a thermal energy storage system of double-pipe helical-coil tube
...Show More Authors

View Publication
Scopus (153)
Crossref (148)
Scopus Clarivate Crossref
Publication Date
Fri Feb 01 2019
Journal Name
Journal Of Economics And Administrative Sciences
Organizational spirituality and its implications for organizational performance: A survey of the opinions of employees of the General Company for Food Industries in Abu Ghraib (Baghdad)
...Show More Authors

The research discusses with organizational spirituality and its implications on the organizational performance in the General Company for Food Industries in Abu Ghraib (Baghdad). The aim of the research was to determine the contribution of organizational spirituality in the organizational performance of the surveyed company. In order to achieve the objectives of the research، two main hypotheses were adopted. Several sub-hypotheses centered on the relationship between organizational spirituality and organizational performance in terms of its dimensions (Meaning work، self-esteem، community affiliation،

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Assessing the efficiency Economic performance of the diyala General company for electrical industries for the Period (2000-2010)
...Show More Authors


     Facing industrial companies many pressures and challenges due to rapid changes in the business environment of contemporary, which requires them to do their performance look more inclusive rather than limiting performance evaluation on the financial perspective in spite of its importance, prompting companies to rethink their reality competitive through the adoption of methodologies and new philosophies to manage competitiveness of total quality management, and re-engineering of production processes, and knowledge management,... etc., as This study framework cognitive and practical "to evaluate the performance of a company Diyala General Electric Industries and how to rehabilitate

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Apr 01 2019
Journal Name
Journal Of Engineering
Investigation of Optimum Heat Flux Profile Based on the Boiling Safety Factor
...Show More Authors

An experimental study is conducted to investigate the effect of heat flux distribution on the boiling safety factor of its cooling channel. The water is allowed to flow in a horizontal circular pipe whose outlet surface is subjected to different heat flux profiles. Four types of heat flux distribution profiles are used during experiments: (constant distribution profile, type a, triangle distribution profile with its maximum in channel center, type b, triangle distribution profile with its maximum in the channel inlet, type c, and triangle distribution profile with its maximum in the channel outlet, type d). The study is conducted using heat sources of (1000 and 2665W), water flow rates of (5, 7 and 9 lit/min). The water

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Rise Velocity and Drag Coefficient of Collapsing Two-Phase Bubble Condensing in an Immiscible Liquid
...Show More Authors

Collapse of the vapor  bubble condensing  in an immiscible  is investigated for  n-pentane and n-hexane vapors condensing in cold water and n-pentane in two different compositions of glycerin- water mixture. The rise velocity and the drag coefficient of the two-phase bubble are measured.

View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Materials Today Sustainability
Structure and performance of polyvinylchloride microfiltration membranes improved by green silicon oxide nanoparticles for oil-in-water emulsion separation
...Show More Authors

View Publication
Scopus (23)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Dec 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
The impact of re-engineering to achieve effective performance level of Ministry of electricity operations/an applied study of process reengineering clean solar cells
...Show More Authors

 The study is dealing with an application reengineering process clean solar cells in the Ministry of electricity,  as aimed at the possibility of the applicability and impact of re-engineering to achieve the level of performance of the Ministry's operations, with the application of the cleaning process  solar cells, developed, improved and found a correlation, statistically significant effect between variable re-engineering and performance as well as the application of process reengineering clean solar cells:1- Before the re-engineering process the total time for cleaning up and solar cell 20 minutes and number of columns performed per day 24 columns and total  columns750 which were completed per month that re

... Show More
View Publication Preview PDF
Crossref