Preferred Language
Articles
/
joe-353
Reduction of Noise and Vibration of Spur Gear by Using Asymmetric Teeth Profiles with Tip Relief
...Show More Authors

Reduction of noise and vibration in spur gear experimentally by using asymmetric teeth profiles with tip relief was presented. Both of classical (symmetric) and asymmetric (with and without tip relief) spur gears are used in this work. Gear test rig was constructed to achieve torsional vibration measuring, and two modified cutters are designed and manufactured to achieve tooth profile modifications. First to cut asymmetric gear tooth with pressure angles (14.5o/25 o) without tip relief for loaded and unloaded tooth sides respectively, and second to cut asymmetric gear tooth with pressure angles (14.5o/25 o) for loaded and unloaded tooth sides respectively with tip relief to achieve best dynamic performance. Dynamic load factor, transmission error and noise level are carried out in this work. Final results showed improvement in dynamic load factor and noise level for asymmetric gear (with and without tip relief) compared with classical spur gear   . 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Dec 31 2024
Journal Name
International Review On Modelling And Simulations (iremos)
Vibration Analysis of Laminated Shallow Shells Under Thermal Loading Using Higher Order Shear Deformation Theory
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental and Theoretical Investigation of Noise Effect in Centrifugal Fan Impeller
...Show More Authors

In this work a study was made in centrifugal fan blower to investigate the effect of impeller blade design on sound pressure level (SPL). Shroud and unshroud impeller of nine blades are used. The sound generation from flow inside the test rig at different positions was displayed by using spectral analyzer. The experiments were carried out in anechoic chamber with small holes in its walls, under ambient condition about (25-27) C ° to avoid the effect of temperature on the sound pressure level. The results showed that (SPL) decreased with the increase of distance from the source about (3-4)dB when distance varied about (0.8-1.06)m, and the (SPL) decreased with the decrease of velocity about (8-12)dB when velocity varied between (13000-260

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of light curing tip distance on the curing depth of bulk fill resin based composites
...Show More Authors

Background: This in vitro study measure and compare the effect of light curing tip distance on the depth of cure by measuring vickers microhardness value on two recently launched bulk fill resin based composites Tetric EvoCeram Bulk Fill and Surefil SDR Flow with 4 mm thickness in comparison to Filtek Z250 Universal Restorative with 2 mm thickness. In addition, measure and compare the bottom to top microhardness ratio with different light curing tip distances. Materials and Method: One hundred fifty composite specimens were obtained from two cylindrical plastic molds the first one for bulk fill composites (Tetric EvoCeram Bulk Fill and Surefil SDR Flow) with 4 mm diameter and 4 mm depth, the second one for Filtek Z250 Universal Restorative

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Dissolution of calcium ion from teeth treated with different concentrations of siwak water extract in comparison with sodium fluoride
...Show More Authors

Background: The miswak is a teeth cleaning twig made from a twig of the Salvadora persica tree (known as arak in Arabic).A traditional alternative to the modern toothbrush, it has a long, well-documented history and is reputed for its medicinal benefits. It also features prominently in Islamic hygienical jurisprudence. Materials and methods: Twenty maxillary first premolars were treated with the selected solutions which included siwak water extract (5%, 10%) and sodium fluoride 0.05% for 2minutes once daily for 20 days interval, deionized water was used as control negative. Then the concentration of the dissolved calcium ion in the etching solution of 2N HCL was measured. Results: The least amount of the dissolved calcium ion was registere

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the relationship between maxillary sinus floor and maxillary posterior teeth root apices using spiral CT scan
...Show More Authors

Background: The purpose of this study is to investigate the relationship between the roots of the maxillary posterior teeth and the maxillary sinus using spiral computed tomography, and measured the distances between the roots of the maxillary posterior teeth and the sinus floor. Materials and Methods: The sample of the present study was a total of 120 Iraqi subject (60 males & 60 females) aged (20-60) years old, who admitted to spiral Computed Tomography scan unit in AL-Zahraa hospital in AL-Kut city to have Computed Tomography scan of the brain and paranasal sinuses who had complaints of headaches or with suspicion of sinusitis but without pathological findings in maxillary sinuses. From November 2012 to April 2013, CT sagittal reconstruc

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
Iraqi Journal Of Agricultural Sciences
Manufacturing And Testing Of Date Palm Vibration Motorized Fronds Cutter
...Show More Authors

Publication Date
Mon Apr 09 2018
Journal Name
Al-khwarizmi Engineering Journal
Construction and Evaluation of a Uniaxial Mechanical Actuated Vibration Shaker
...Show More Authors

In the present paper a low cost mechanical vibration shaker of rotating unbalanced type with uniaxial shaking table was designed and constructed in an attempt to provide opportunities for experimental testing and application of vibration in experimental modal analysis, stress relief of weldments, effect of vibration on heat transfer and seismic testing of civil engineering structures. Also, it provides unexpressive solution to enhance the knowledge and technical skills of students in mechanical vibration laboratory. The shaker consists of a five main parts shaker frame, shaker table, flexible support, drive motor, and eccentricity mechanism. The experimental results show that the amplitude of the shaker is increased with increasing the f

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Drag Reduction of Crude Oil Flow in Pipelines Using Sodium Dodecyl Benzene Sulfonate Surfactant
...Show More Authors

In the present work, a closed loop circulation system consist of three testing sections was designed and constructed. The testing sections made from (3m) of commercial carbon steel pipe of diameters(5.08, 2.54 and 1.91 cm) . Anionic surfactant  (SDBS )with  concentrations  of (50,  100,  150, 200 and 250 ppm)  was tested as a drag reducing  agent.  The additive(SDBS)studied using crude oil from south of Iraq. The flow rates of crude oil were used in 5.08 and 2.54 cm I.D. pipes are (1 - 12) m3/hr while (1-6) m3/hr were used in 1.91 cm J .D. pipe . Percentage drag reduction (%Dr) was found to increase by increasing solution velocity, pipe diameter and additives concentration (i.e. increasi

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Viscosity Reduction of Sharqi Baghdad Heavy Crude Oil Using Different Polar Hydrocarbons, Oxygenated Solvents
...Show More Authors

This work studied the facilitation of the transportation of Sharqi Baghdad heavy crude oil characterized with high viscosity 51.6 cSt at 40 °C, low API 18.8, and high asphaltenes content 7.1 wt.%, by reducing its viscosity from break down asphaltene agglomerates using different types of hydrocarbon and oxygenated polar solvents such as toluene, methanol, mix xylenes, and reformate. The best results are obtained by using methanol because it owns a high efficiency to reduce viscosity of crude oil to 21.1 cSt at 40 °C. Toluene, xylenes and reformate decreased viscosity to 25.3, 27.5 and 28,4 cSt at 40 °C, respectively. Asphaltenes content decreased to 4.2 wt. % by using toluene at 110 °C. And best improvement in API of the heavy crude o

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of surface treatments and thermocycling on shear bond strength of various artificial teeth with different denture base materials
...Show More Authors

Background: Separation and deboning of artificial teeth from denture bases present a major clinical and labortory problem which affect both the patient and the dentist. The optimal bond strength of artificial teeth with denture base reinforced with nanofillers and flexible denture bases and the effect of thermo cycling should be evaluated. This study was conducted to evaluate and compare the shear bond strength of artificial teeth (acrylic and porcelain) with denture bases reinforced by 5% Zirconium oxide nanofillers and flexible bases under the effect of different surface treatments and thermo cycling and comparing the results with conventional water bath cured denture bases. Material and methods: Two types of artificial teeth; acrylic and

... Show More
View Publication Preview PDF