Preferred Language
Articles
/
joe-351
Dynamic Analysis of Fluid – Structure Interaction of Axial Fan System
...Show More Authors

Fluid-structure interaction method is performed to predict the dynamic characteristics of axial fan system. A fluid-structure interface physical environment method (monolithic method) is used to couple the fluid flow solver with the structural solver. The integration of the three-dimensional Navier-Stokes equations is performed in the time Doman, simultaneously to the integration of the three dimensional structural model. The aerodynamic loads are transfer from the flow to structure and the coupling step is repeated within each time step, until the flow solution and the structural solution have converged to yield a coupled solution of the aeroelastic set of equations. Finite element method is applied to solve numerically the Navier-Stockes equations coupled with the structural equations The first ten eigenvalue (natural frequency), the first ten eigenvector (mode shape) and effective stress for each part of a rotor system and complete system assembly are predicted.

The validity of the predicted dynamic characteristics of duct fan system was confirmed experimentally by investigating geometrically similar fan system test rig. Good agreement of dynamic characteristics is observed between experimental and numerical results.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 04 2021
Journal Name
Multimedia Tools And Applications
Attention enhancement system for college students with brain biofeedback signals based on virtual reality
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Dec 31 2021
Journal Name
International Journal Of Intelligent Engineering And Systems
Airborne Computer System Based Collision-Free Flight Path Finding Strategy Design for Drone Model
...Show More Authors

View Publication
Scopus (10)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
International Journal Of Electrical And Electronic Engineering & Telecommunications
5G New Radio LDPC Codes Based Generalized Joint Subcarrier-Time Index Modulation DCSK System
...Show More Authors

Low-Density-Parity-Check (LDPC) codes are a cornerstone for achieving robust error correction capabilities in 5G New Radio applications, significantly improving the reliability of data transmission across noisy and unpredictable wireless channels. Since an evaluation and discussion of the performance with channel coding is significantly absent in two-dimensional Index Modulation (IM)-Differential Chaos Shift Keying (DCSK) schemes. Therefore, in this study, the 5G new radio LDPC codes based generalized joint subcarrier-time index modulation DCSK system (5G NR-LDPC-GJSTIM-DCSK) is proposed, where 5G NR-LDPC codes are used as channel coding. The aim is to improve the system’s performance specifically across AWGN (additive white gauss

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2017
Journal Name
International Journal Of Heat And Mass Transfer
Melting enhancement in triplex-tube latent thermal energy storage system using nanoparticles-fins combination
...Show More Authors

View Publication
Scopus (214)
Crossref (209)
Scopus Clarivate Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Energies
Solidification Enhancement in a Triple-Tube Latent Heat Energy Storage System Using Twisted Fins
...Show More Authors

This work evaluates the influence of combining twisted fins in a triple-tube heat exchanger utilised for latent heat thermal energy storage (LHTES) in three-dimensional numerical simulation and comparing the outcome with the cases of the straight fins and no fins. The phase change material (PCM) is in the annulus between the inner and the outer tube, these tubes include a cold fluid that flows in the counter current path, to solidify the PCM and release the heat storage energy. The performance of the unit was assessed based on the liquid fraction and temperature profiles as well as solidification and the energy storage rate. This study aims to find suitable and efficient fins number and the optimum values of the Re and the inlet tem

... Show More
View Publication
Scopus (53)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Numerical simulation to the effect of applying rationing system on the stability of the Earth canal: Birmana canal in Iraq as a case study
...Show More Authors
Abstract<p>Extreme conditions will cause the water level of high fill canal segment to change suddenly, which will affect the velocity and pore pressure of the slope. A 9 km irrigation earth canal in the city of Alsyahy, 15 km away from Al-Hilla city, and branching off from the left side of Shatt Al-Hilla at 57 km, was studied. The aim of this work is to study and analyze the effect of rationing system on the Birmana earthen canal during rapid drawdown case. Finite element modeling with Geo-Studio software was used in the present study to analyze the combined seepage and slope stability for three cycles. The resulting minimum safety factor obtained from the analysis using the saturated and</p> ... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Dec 31 2024
Journal Name
Anbar Journal Of Agricultural Sciences
EFFECT OF ACIDS AND ORGANIC NUTRIENTS ON CAULIFLOWER GROWTH AND YIELD AND WATER USE EFFICIENCY AND FERTILIZER PRODUCTIVITY OF A MODIFIED NFT HYDROPONICS SYSTEM
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Fri Nov 26 2021
Journal Name
Nanomaterials
Solidification Enhancement in a Multi-Tube Latent Heat Storage System for Efficient and Economical Production: Effect of Number, Position and Temperature of the Tubes
...Show More Authors

Thermal energy storage is an important component in energy units to decrease the gap between energy supply and demand. Free convection and the locations of the tubes carrying the heat-transfer fluid (HTF) have a significant influence on both the energy discharging potential and the buoyancy effect during the solidification mode. In the present study, the impact of the tube position was examined during the discharging process. Liquid-fraction evolution and energy removal rate with thermo-fluid contour profiles were used to examine the performance of the unit. Heat exchanger tubes are proposed with different numbers and positions in the unit for various cases including uniform and non-uniform tubes distribution. The results show that

... Show More
View Publication
Scopus (14)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Mar 06 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of the anterior loop of the mental nerve incidence and extension in different age groups in Sulaimania city using digital panoramic imaging system
...Show More Authors

Background: The anterior loop of mental nerve is commonly described as that part of the neurovascular bundle that transverses anterior and inferior to the mental foramen only to loop back to exit the mental foramen. The aim of the study is to evaluate the incidence and extension of anterior loop of mental nerve by using digital panoramic imaging system to avoid nerve damage during different surgical procedures in dentistry. Materials and Method: Panoramic image was taken for all 400 patients and stored in the computer. Then Horizontal and Vertical for the anterior loop extension when exist was measured and recorded in a special case sheet prepared for each subject. Results: Results indicated that out of 400 patients there were only 25 pat

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Influence of Temperature and Flow Velocity on the Corrosion Inhibition of Low Carbon Tubes in Recirculating Water System by a Dicomponent Inhibitor Blend
...Show More Authors

View Publication Preview PDF