Experimental Evaluation of Thermal Performance of Solar Assisted Vapor Compression Heat Pump
...Show More Authors

The thermal performance of indirect expansion solar assisted heat pump, IX-SAHP, was investigated experimentally under Iraqi climate. An Indirect-Solar Assisted Heat Pump system was designed, built, instrumented and tested. Experimental tests were conducted by varying the controlling parameters to investigate their effects on the thermal performance of the IX-SAHP such as cooling water flow rate, heating water flow rate, ambient temperature and solar radiation intensity. The investigation covered values of cooling water flow rate of (2, 3, 4, 5 l/min) and heating water flow rate of (2, 3, 4, 5 l/min) under meteorological condition of Baghdad from November 2014 to January 2015.

The results indicated that the performance of the IX-SAHP is not dependent on the heating water flow rate. On the contrary of heating water flow rate, cooling water flow rate has significant effect on the thermal performance of the system. The COP of the heat pump system is decreased with increasing cooling water flow rate. The collector heat gain increase with increasing the solar radiation and ambient temperature, this leads to increase in COP from 2.2 to 2.39 as the ambient temperature and solar radiation increase from 9.9℃ and 268 W/m2 to 14.9 ℃ and 689 W/m2 respectively.

 

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Engineering
Numerical Investigation of the Effect of Inserted Twisted Tape inside Submerged Bundle Tubes on its Thermal Performance
...Show More Authors

Twisted tape insertion in smooth plain tube is one of types of passive methods that is used to enhance heat transfer. Swirl fluid flow inside tube and related heat transfer characteristics are very complex. ANSYS FLUENT (V 16.1) and ASPEN industrial program are used in analyzing this technique for enhancement heat transfer. A circular plain tube has length L=8534mm and 17 mm inner diameter with twisted tape has twist ratio of y = (H/D) = (150/17) =8.8 along with a plain tube were considered for this study. Eight Reynolds numbers (Re) of 784, 1000, 2000, 3000, 4000, 5000, 6000 and 7000 are used to analyze the response of thermal performance. Crude oil API 28 exit temperature, film heat transfer coefficient, Nusselt number

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jun 09 2023
Journal Name
Journal Of Research In Medical And Dental Science
Evaluation of the Anti-inflammatory of Leucaena leucocephala extracts in Experimental Rats.
...Show More Authors

A lot of previous studies are concerned with the evaluation of the anti-inflammatory activity of medicinal plants because it considered cheap and are believed to possess minimal side effects. Leucaena leucocephala didn’t evaluate globally for its anti-inflammatory effect yet though some of it’s already separated and identified secondary metabolites were studied and proved to exert many pharmacological activities besides their effect on lowering the pro-inflammatory cytokines like TNF-α and IL-6. So, there was an interest to evaluate the biological effect of Leucaena leucocephala as a novel anti-inflammatory agent was the first motivation to start an in vivo study using a rat population. The N-butanol and ethyl acetate extracts were cho

... Show More
View Publication Preview PDF
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Experimental Evaluation of PV Panel Efficiency Using Evaporative Cooling Integrated with Water Spraying
...Show More Authors

In this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Performance Analysis of Four Conceptual Designs for the Air Based Photovoltaic / Thermal Collectors
...Show More Authors

The  thermal  and  electrical  performance  of  different  designs  of  air  based  hybrid photovoltaic/thermal collectors is investigated experimentally and theoretically. The circulating air is used to cool PV panels and to collect the absorbed energy to improve their performance. Four different collectors have been designed, manufactured and instrumented namely; double PV panels without cooling (model I), single duct double pass collector (model II), double duct single pass (model III), and single duct single pass (model IV) . Each collector consists of: channel duct, glass cover, axial fan to circulate air and two PV panel in parallel connection. The temperature of the upper and

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
Preparation of polyaniline polymer and using it as a Vapor sensor of acids
...Show More Authors

 Polyaniline organic Semiconductor polymer was prepared by oxidation polymerization by adding hydrochloric acid concentration of 0.1M and potassium per sulfate concentration of 0.2M to 0.1M of aniline at room temperature, the polymer was deposited at glass substrate, the structural and optical properties were studies through UV-VIS, IR, XRD measurements, films have been operated as a sensor of vapor  H2SO4 and HCl  acids.

View Publication Preview PDF
Crossref
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
EXPERIMENTAL INVESTIGATION OF LAMINAR NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE WITH AND WITHOUT INSIDE PARTITIONS
...Show More Authors

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*10

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Inorganic Chemistry Communications
Investigation of performance and efficiency of donor-π-bridge-acceptor based material solar cell
...Show More Authors

The novel groups of organic chromophores containing triphenylamine (TPA) (ATP-I to ATP-IV) have been constructed by structural modification of electron donors with substitution biphenyl and bipyridine rings inserting a π-linkage. Density functional theory (DFT) and time-dependent type of it (TD-DFT) have been operated to study results of donating ability of TPA and spacer on absorption, geometrical, photovoltaic, and energetic attributes of these sensitizers. Structural attributes have been revealed that incorporation of TPA, acceptor and π bridge include a perfect coplanar conformation in TPA-III. Based on frequency computations and ground-state optimization, bandgap (Eg) energy, ELUMO, EHOMO have been determined. For enlightening maximu

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of The Mechanical Behavior Of Biomedical Materials
Bioactivity, cytocompatibility and thermal properties of experimental Bioglass-reinforced composites as potential root-canal filling materials
...Show More Authors

To evaluate the bioactivity and the cytocompatibility of experimental Bioglass-reinforced polyethylene-based root-canal filling materials. The thermal properties of the experimental materials were also evaluated using differential scanning calorimetry, while their radiopacity was assessed using a grey-scale value (GSV) aluminium step wedge and a phosphor plate digital system. Bioglass 45S5 (BAG), polyethylene and Strontium oxide (SrO) were used to create tailored composite fibres. The filler distribution within the composites was assessed using SEM, while their bioactivity was evaluated through infrared spectroscopy (FTIR) after storage in simulated body fluid (SBF). The radiopacity of the composite fibres and their thermal properties were

... Show More
View Publication Preview PDF
Crossref (27)
Crossref
Publication Date
Mon Jul 21 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of shear bond strength of artificial teeth to heat cure acrylic and high impact heat cure acrylic using autoclave processing method
...Show More Authors

Background: Debonding and fracture of artificial teeth from denture bases are common clinical problem, bonding of artificial teeth to heat cure acrylic and high impact heat cure acrylic denture base materials with autoclave processing method is not well known. The aim of this study was to evaluate the effect of autoclave processing method on shear bond of artificial teeth to heat cure denture base material and high impact heat cure denture base material. Materials and methods: Heat polymerized (Vertex) and high impact acrylic (Vertex) acrylic resins were used. Teeth were processed to each of the denture base materials after the application of different surface treatments. The sample (which consist of artificial tooth attached to the dentur

... Show More