Preferred Language
Articles
/
joe-319
Heat Transfer Characteristics of a Fluid Flow in Multi Tube Heat Exchanger Fitted with Perforated Fins
...Show More Authors

The heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were building up to cover the experimental work for the range of Reynolds number (7500-17500). The experimental results show that average Nusselt number of the six circular perforations fins model is about 11.08 % higher than that for solid fin model and with triangular perforations model is about 10.12 % higher than that for the solid fin. Triangular perforation finned heat exchanger model gives  a best result than the other models due to excessive increment in the )Nu( in comparison with other models take in consideration pressure drop. The results were validated with previous work and the comparison between the experimental and numerical shows a good agreement with a maximum deviation ±10% between them.

 

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Apr 03 2024
Journal Name
Al- Anbar Medical Journal
Hypervirulent and the Multi-Drug Resistant Klebsiella oxytoca: A New Emerging Pathogen in Baghdad Hospitals, Iraq
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Applied Energy
Deep clustering of Lagrangian trajectory for multi-task learning to energy saving in intelligent buildings using cooperative multi-agent
...Show More Authors

The intelligent buildings provided various incentives to get highly inefficient energy-saving caused by the non-stationary building environments. In the presence of such dynamic excitation with higher levels of nonlinearity and coupling effect of temperature and humidity, the HVAC system transitions from underdamped to overdamped indoor conditions. This led to the promotion of highly inefficient energy use and fluctuating indoor thermal comfort. To address these concerns, this study develops a novel framework based on deep clustering of lagrangian trajectories for multi-task learning (DCLTML) and adding a pre-cooling coil in the air handling unit (AHU) to alleviate a coupling issue. The proposed DCLTML exhibits great overall control and is

... Show More
View Publication
Scopus (38)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Engineering
Dynamic Analysis of Fluid – Structure Interaction of Axial Fan System
...Show More Authors

Fluid-structure interaction method is performed to predict the dynamic characteristics of axial fan system. A fluid-structure interface physical environment method (monolithic method) is used to couple the fluid flow solver with the structural solver. The integration of the three-dimensional Navier-Stokes equations is performed in the time Doman, simultaneously to the integration of the three dimensional structural model. The aerodynamic loads are transfer from the flow to structure and the coupling step is repeated within each time step, until the flow solution and the structural solution have converged to yield a coupled solution of the aeroelastic set of equations. Finite element method is applied to solve numerically

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 01 2025
Journal Name
Socar Proceedings
Enhanced permeability estimation in non-cored wells using a modified flow zone index-permeability crossplot: a case study of carbonate reservoirs
...Show More Authors

The permeability estimates for the uncored wells and a porosity function adopting a modified flow zone index-permeability crossplot are given in this work. The issues with implementing that approach were mostly crossplots, due to the influence of geological heterogeneity, did not show a clear connection (scatter data). Carbonate reservoir flow units may now be identified and characterized using a new approach, which has been formally confirmed. Due to the comparable distribution and flow of clastic and carbonate rock fluids, this zoning method is most effective for reservoirs with significant primary and secondary porosity. The equations and correlations here are more generalizable since they connect these variables by combining cor

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Thu Sep 24 2020
Journal Name
F1000research
Characterization of flow cytometric immuno-phenotyping of acute myeloid leukemia with minimal differentiation and acute T-cell lymphoblastic leukemia: A retrospective cross-sectional study
...Show More Authors

Background: Acute leukemias (ALs) are a heterogeneous group of malignancies with various clinical, morphological, immunophenotypic, and molecular characteristics. Distinguishing between lymphoid and myeloid leukemia is often performed by flow cytometry. This study aimed to evaluate the immunophenotypic characterization and expression of immuno-markers in both acute myeloid leukemia (AML-M0) and acute T-cell lymphoblastic leukemia (T-ALL).

Methods: A retrospective cross-sectional study was conducted in the Pathology Department/Teaching Laboratories/Medical City/Iraq and included all patients newly diagnosed with AL from 5 January to 10 December 2018. Immunophenotypic analysis wa

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Fuzzy Multi-Objective Capacitated Transportation Problem with Mixed Constraints using different forms of membership functions
...Show More Authors

In this research, the problem of multi- objective modal transport was formulated with mixed constraints to find the optimal solution. The foggy approach of the Multi-objective Transfer Model (MOTP) was applied. There are three objectives to reduce costs to the minimum cost of transportation, administrative cost and cost of the goods. The linear membership function, the Exponential membership function, and the Hyperbolic membership function. Where the proposed model was used in the General Company for the manufacture of grain to reduce the cost of transport to the minimum and to find the best plan to transfer the product according to the restrictions imposed on the model.

View Publication Preview PDF
Crossref
Publication Date
Tue Jan 20 2026
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Effects of a Chelated Multi-Micronutrient Nanofertilizer on the Liver ofAlbino Rats: A Biochemical and Histopathological Assessment
...Show More Authors

Nanofertilizers offer a promising solution to increase crop yields amid increasing population pressure. Yet  there have been safety concerns about their use, particularly in challenging conditions. This work was designed to assess the toxicological effects of a chelated multi-micronutrient nanofertilizer on albino rats (Rattus norvegicus) as non-target organisms, focusing on the liver, which has important metabolic functions. Thirty-five animals were weighed and randomly divided into 5 groups (n=7). A negative control group was included, and four experimental groups (C1-C4) were given the test item. The dosing regimen for the experimental groups was 15 oral doses of nanofertilizer every other day for 29 days. All the groups were

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Volumetric Mass Transfer Capacity Coefficient in the RTL Extractor
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
INTERACTION EFFECTS OF HYDRODYNAMICALLY FULLY DEVELOPED PRIMARY FLOW AND SECONDARY FLOW IN THE THERMAL ENTRANCE REGION OF ANNULAR DUCT
...Show More Authors

Experiments have been conducted to study the local and average heat transfer by mixed
convection for hydrodynamically fully developed, thermally developing and fully developed
laminar upward air flow in an inclined annulus with adiabatic inner cast iron tube and uniform
heated outer aluminum tube with an aspect ratio ( Ω = 0.72) and (L/Dh≈40) for both calming and
test sections). A wide range of Reynolds number from 859 to 2024 has been covered, and heat
flux has been varied from 159 W/m2 to 812 W/m2 (these values of heat flux and Reynolds
number gave Richardson number range from 0.03 to 0.٣٨), with angles of annulus inclination
φ =0o (horizontal position), φ =60o (inclined position), and φ =90o (vertical posi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
New sensitive turbidimetric method for determination of losartan potassium in pharmaceutical formulations using flow injection combined with homemade turbidimeter
...Show More Authors

Scopus (1)
Scopus