The ground level ozone concentration at different locations in Baghdad city was identified. Five
different sites have been chosen to identify the ground level ozone concentration. Al- Dora and Al-
Za'afarania were chosen as areas contained point source ( power plant station ) in addition to high traffic
load , while Al –Uma park, Aden square and Al-Mawal square were chosen as area contained heavy
traffic only (line source). The measurement focuses on spring and fall because these periods display
favorable meteorology to ozone formation. During the research period the maximum values (peaks) for
ground level ozone concentration were observed at fall: at Al-Za'afarania area 101ppb as an average, at
Al-Dora 87 ppb as an average and at line source areas 48 ppb as an average. Among the line sources area
Al-Mawal square represent the highest peak value at fall 68 ppb. At spring the peaks of ozone
concentration observed to be at the same height, 50 ppb for all sites. The downwind sites from the power
plant stations at Al-Dora and Al-Za'afarania areas record higher ozone peaks compared with up wind
sites. It can be concluded that the effect of power plant stations in forming ozone is larger than traffic
load.
The comparison between the ground level ozone concentrations that measured during the research period in spring and fall, and the ambient air quality standards (AAQS) shows that:
• No exceeded levels were observed in spring for all sites.
• In fall the AAQS for ozone was exceeded in Al-Za'afarania area at 12: PM, 1: PM, 2: PM and 3:
PM, and in Al-Dora at 2: PM.
Water drainage pattern in the rivers and changed the nature of the renewed feeding areas
in the basin in terms of topographic and geological conditions and climate in addition to the
human role in organizing the process flow within these basins. This study addressed the
development of the Tigris River Hydrological in the city of Baghdad and found that the
annual rate of water drainage in the Tigris River was driven down very significantly,
especially in the past twenty years, and since 1996 up to 2014 record flow rates of less than
the overall rate of discharge of water, a (950 m3 / s ), in addition to the quarterly decrease the
discharge rates, especially since the beginning of the year 2000 and took converge all fo
Background: The quality of drinking water is directly related to community health. Therefore, improving the quality of drinking reflects positively on the health situation in general. The studies that deal with the quality of drinking water in the city of Baghdad in terms of chemical or microbial content are very scanty. Objective: The current review highlights the most important studies and research articles that concern the quality of drinking water, both bottled water and tap water, in terms of chemical and biological contamination and chemophysical specifications for drinking water. Abstract: Studies have shown that drinking water in the city of Baghdad, especially tap water, contains certain levels of heavy metals,
... Show MoreRadon is the most dangerous natural radioactive component affecting the human population, since it is a radioactive gas that results from the decomposition process of uranium deposits in soil, rocks, and water, and it is damaging both humans and the ecosystem. The radon concentrations and exhalation rate in soil samples from various locations were determined using a passive approach with a CR-39 (CR-39 is Columbia Resin #39; it is allyl diglycol carbonate C12H18O7) detector in Amiriya region in Baghdad Governorate. The average values of radon concentrations are ranged from 47.3 to 54.2 Bq·m−3. From the obtained results, we can conclude that the values of all studied locations are
This study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in the study were
... Show MoreThis study aims to evaluate drinking water quality at the Al Wahda plant (WTP) in Baghdad city. A conventional water treatment plant with an average flow rate of 72.82 MLD. Water samples were taken from the influent and effluent of the treatment plant and analyzed for some physicochemical and biological parameters during the period from June to November 2020. The results of the evaluation indicate that treated water has almost the same characteristics as raw water; in other terms, the plant units do not remove pollutants as efficiently as intended. Based on this, the station appears to be nothing more than a series of water passage units. However, apart from Total dissolved solids, the mean values of all parameters in th
... Show MoreAbstract
Through social service tasks for the elderly, it natural for elder people to have some attitudes about the quality and nature of provided services, whether negative or positive. Accordingly, the current research is an attempt to investigate the attitudes of the elderly toward the social service provided to them in the nursery homes. The research sample included 60 elderly people chosen from the nursey home at Al-Karrada district and then a scale of attitudes was administered to them that had proved its reliability and validity. The study concluded with a set of recommendations and suggestions were.
In the present study, semi – batch experiments were conducted to investigate the efficiency of ozone microbubbles (OMBs) in the treatment of aqueous dye solutions methylene orange under different reaction conditions such as effect of initial solution pH , ozone generation rate and initial MO-concentration. The results showed that the removal of MO by OMBs were very high at the acidic and alkaline media and upon increasing the generation rate of ozone from 0.498 to 0.83 mg/s, the removal efficiency dramatically increased from 75to 100% within 15 min. The rate of oxidation reaction followed a pseudo first- order kinetic model. The results demonstrated that OMBs is efficient in terms of the decline of methylene orange c
... Show MoreIn this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions. Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 m
... Show More