Experiments have been conducted to study the local and average heat transfer by mixed
convection for hydrodynamically fully developed, thermally developing and fully developed
laminar upward air flow in an inclined annulus with adiabatic inner cast iron tube and uniform
heated outer aluminum tube with an aspect ratio ( Ω = 0.72) and (L/Dh≈40) for both calming and
test sections). A wide range of Reynolds number from 859 to 2024 has been covered, and heat
flux has been varied from 159 W/m2 to 812 W/m2 (these values of heat flux and Reynolds
number gave Richardson number range from 0.03 to 0.٣٨), with angles of annulus inclination
φ =0o (horizontal position), φ =60o (inclined position), and φ =90o (vertical position). The hydrodynamically fully developed condition has been achieved by using aluminum annulus
(calming section) has the same dimensions as test section and has connected with it by Teflon
piece. The average Nusselt numbers have been correlated with the product of (Richardson
number and Reynolds number) and compared with available literature and showed satisfactory
agreement. The temperature and local Nusselt number profiles results have revealed that the
secondary flows created by natural convection have a significant effect on the heat transfer
process.
This study investigates the possibility of using waste plastic as one of the components of expired lead-acid batteries to produce lightweight concrete. Different percentages of lead-acid battery plastic were used in the production of lightweight concrete. The replacements were (70, 80 and 100%) by volume of the fine and coarse aggregate. Results demonstrated that a reduction of approximately 23.6% to 35% in the wet density was observed when replacement of 70% to 100% of the natural aggregate by lead-acid battery plastic. Also, the compressive strength decreased slightly with the increase in plastic content at different curing ages of 7, 28, 60, 90, 120 days. The lowest value of compressive strength was (20.7 MPa) for (wa
... Show MoreA design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show MoreThis study was carried out from February to October 2012 in six semi salty ponds in Gwer sub-district which is the first work in the area. A total of 32 species and 2 genera of algae where reported as the new records. Mostly the non diatoms are belonging to Cyanophyta, Chlorophyta, Euglenophyta, Cryptophyta, Chrysophyceae, while diatoms or Bacilariophyceae are belong to pennals- order.
A numerical simulation is made on the thermal lensing effect in an laser diode end-pumped Nd:YAG laser rod. Based on finite element method (FEM), the laser rod temperature distribution is calculated and the focal length is deduced for a Gaussian and super-Gaussian pump beam profiles.
At the pump power of 20W, the highest temperature located at the center of end-pumped face was 345K, and the thermal lens focal length was 81.4mm along the x-z axis.
The results indicate that the thermal lensing effect sensitively depend on the pump power, waist radius of the pump beam and the pump distribution in a laser rod geometry.
Vitamin D is a fat-soluble vitamin with antioxidant and DNA protecting properties , Levofloxacin is a member of the fluoroquinolone drug class, Its broad-spectrum bactericidal effect affects both Gram-positive and Gram-negative bacteria.
The goal of the study is to analyze the haematology analysis in rats received levofloxacin and show the preventive impact of vitamin D3 by analyzing the haematology parameters: packed cell volume (PCV), mean corpuscular hemoglobin concentration(MCHC),haemoglobin (HB), red blood cell (RBC), mean corpuscular volume (MCV),meancorpuscular haemoglobin(MCH), WBC ,differential WBC, and Platelets.
The study included 42 rats divided into 6 groups each group 7 rats. group I negative control
... Show MoreAbrus precatorius L. is an important medicinal plant belonging to family Fabaceae. The present study was conducted to perform pre-clinical safety evaluation and study the pharmacological effects of the ethanolic seeds extract of A. precatorius in management of pain, psychiatric and neurological conditions. Acute toxicity was performed to study the general behavioural pattern of mice after treatment with the test extract (single doses of 1000, 2000, 3000,4000,5000 mg/kg, body weight) and sub-acute toxicity studies were performed to study the toxic effects of the test extract (1000,2000,3000 mg/kg, per os for 14 days) on different haematological parameters, body and organ weight and histopathology of liver and kidney. The toxicological evalua
... Show More