In this research the relation between skin resistances and standard penetration test of over consolidated
clay soils has been studied. The research includes doing boreholes at Babil governorate in Iraq to get
undisturbed samples and standard penetration test. Determination skin friction from direct shear test between
smooth concrete and soil was explored in laboratory for design purposes and correlated with standard
penetration test values. In many foundation design problems, the shear strength between soil and
foundation materials were estimated or correlated without any direct methods for measurement.
Twelve strain controlled direct shear tests were performed simulate the shear strength interaction
between smooth concrete and undisturbed over consolidated silty clay, determine the soil – foundation
interface friction, considering the following variables :(1) over consolidation ratio OCR between 1.4 to
2.4 (2) Concrete, smooth surface, (3) Undisturbed samples, (4) Variation of the normal load between the
friction surface. The results showed that both cohesion and internal friction should be considered in
evaluating skin friction. The results of cohesion and angle of internal friction were correlate with the
standard penetration test SPT –N . Interface friction angle was 14.5° , while the adhesion was 15.5 kPa.
The ultimate shear strength was mobilized through 10%- 16% strain in the direction of shear surface. .
A fairly good correlation between the N70-value and the interface friction parameters were established
for determination unit skin friction for driven piles. Finally, based on the test results, a simple relation was
proposed to relate the N70 value and interface friction of silty clay soils for a range of N70 between 12 and 20.
The article describes a certain computation method of -arcs to construct the number of distinct -arcs in for . In this method, a new approach employed to compute the number of -arcs and the number of distinct arcs respectively. This approach is based on choosing the number of inequivalent classes } of -secant distributions that is the number of 4-secant, 3-secant, 2-secant, 1-secant and 0-secant in each process. The maximum size of -arc that has been constructed by this method is . The new method is a new tool to deal with the programming difficulties that sometimes may lead to programming problems represented by the increasing number of arcs. It is essential to reduce the established number of -arcs in each cons
... Show MoreThis investigation was conducted to recognize the structure for (RHETI version 2.5 1999) by using exploratory and confirmatory factor analysis. Sample of (620) student of Al-Mustansrya University were administered the (RHETI).
The data of their responses was analyzed by using (PAF) and oblique rotating .
The findings explored (9) factors as one factor for each type and (184) items were loaded by the factors: (60) item for feeling center, (61) items for instinctive center and (63) items for thinking center.
Results of confirmatory factorial analysis supported a model designed by the researcher depended upon a theoretical views of Riso and Hudson
... Show MoreHydrogen sulfide removal catalyst was prepared chemically by precipitation of zinc bicarbonate at a controlled pH. The physical and chemical catalyst characterization properties were investigated. The catalyst was tested for its activity in adsorption of H2S using a plant that generates the H2S from naphtha hydrodesulphurization and a unit for the adsorption of H2S. The results comparison between the prepared and commercial catalysts revealed that the chemical method can be used to prepare the catalyst with a very good activity.
It has observed that the hydrogen sulfide removal over zinc oxide catalyst follows first order reaction kinetics with activation energy of 19.26 kJ/mole and enthalpy and e
... Show MoreRecently, increasing material prices coupled with more acute environmental awareness and the implementation of regulation has driven a strong movement toward the adoption of sustainable construction technology. In the pavement industry, using low temperature asphalt mixes and recycled concrete aggregate are viewed as effective engineering solutions to address the challenges posed by climate change and sustainable development. However, to date, no research has investigated these two factors simultaneously for pavement material. This paper reports on initial work which attempts to address this shortcoming. At first, a novel treatment method is used to improve the quality of recycled concrete coarse aggregates. Thereafter, the treated recycled
... Show MoreThis paper is concerned with preliminary test single stage shrinkage estimators for the mean (q) of normal distribution with known variance s2 when a prior estimate (q0) of the actule value (q) is available, using specifying shrinkage weight factor y( ) as well as pre-test region (R). Expressions for the Bias, Mean Squared Error [MSE( )] and Relative Efficiency [R.Eff.( )] of proposed estimators are derived. Numerical results and conclusions are drawn about selection different constants including in these expressions. Comparisons between suggested estimators with respect to usual estimators in the sense of Relative Efficiency are given. Furthermore, comparisons with the earlier existi
... Show MoreIn this paper we generalize Jacobsons results by proving that any integer in is a square-free integer), belong to . All units of are generated by the fundamental unit having the forms
Our generalization build on using the conditions
This leads us to classify the real quadratic fields into the sets Jacobsons results shows that and Sliwa confirm that and are the only real quadratic fields in .
A simple technique is proposed in this paper for estimating the coefficient of permeability of an unsaturated soil based on physical properties of soils that include grain size analysis, degree of saturation or water content, and porosity of the soil. The proposed method requires the soil-water characteristic curve for the prediction of the coefficient of permeability as most of the conventional methods. A procedure is proposed to define the hydraulic conductivity function from the soil water characteristic curve which is measured by the filter paper method. Fitting methods are applied through the program (SoilVision), after indentifying the basic properties of the soil such as Attereberg limits, specific gravity, void ratio, porosity, d
... Show MorePurpose This study was design to investigate of Purpose This study was design to investigate of P. aeruginosa, an example of Gram-negative bacteria, in seven primary and secondary schools of Baghdad city, and the effects of Ethanol and Dettol of P. aeruginosa biofilm. Design/methodology/approach Seventy swabs were collected from seven primary and secondary schools of Baghdad city, Iraq, during November -December 2022. Swabs were collected from classes desk, doors handles, students hands and water taps. Standard microbiological testing methods were used on the samples for isolation and identification. The ability of bacteria to form biofilm and the effects of Ethanol and Dettol on “preformed” biofilms was examined by microtiter plate wi
... Show MoreThe complexity and partially defined nature of jet grouting make it hard to predict the performance of grouted piles. So the trials of cement injection at a location with similar soil properties as the erecting site are necessary to assess the performance of the grouted piles. Nevertheless, instead of executing trial-injected piles at the pilot site, which wastes money, time, and effort, the laboratory cement injection devices are essential alternatives for evaluating soil injection ability. This study assesses the performance of a low-pressure laboratory grouting device by improving loose sandy soil injected using binders formed of Silica Fume (SF) as a chemical admixture (10% of Ordinary Portland Cement OPC mass) to di
... Show More