Preferred Language
Articles
/
joe-2986
EXPERIMENTAL INVESTIGATION OF LAMINAR NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE WITH AND WITHOUT INSIDE PARTITIONS
...Show More Authors

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*108) and aspect ratio of (0.5). 22 different configurations of partition were used in this study these are:
a) Undivided enclosure (no – partition).
b) (21) Cork partitions of different shapes.
Empirical correlations for average Nusselt number are obtained for the different cases tested. The results show that heat transfer is independent on the partition position according to the cold wall and according to the upper or lower walls, while it shows that heat transfer is sensitive to:
1. Rayleigh number (Ra), which increase with increasing Ra.
2. Aperture height ratio (Ap=hp/H), which is found that when Ap= 5/6 (case 2,3), the reduction in heat transfer is 10.3%, while when Ap=1/2 (case 4,5), the reduction is 17.2% compared with the non partitioned enclosure.
3. Aperture position according to the height, which is found that when the aperture at the centre of the partition (case 13), the reduction in heat transfer is 16.7%, while when the aperture displaced to the upper surface (case 14), the reduction is 19% compared with the non partitioned enclosure.
4. Partition thickness (t), which is found that when t = 10 mm (case 4,5) the reduction in heat transfer is 17.2%, while when t = 150 mm (case 16) the reduction is 20.5% compared with the non partitioned enclosure.
5. Partition inclination (), which is found that the rate of heat transfer reduced with increasingas shown:
a. For = 30 toward the cold wall (case 22), the reduction in heat transfer is 18.2%.
b. For = 45 toward the cold wall (case 18), the reduction in heat transfer was 21.9%.
c. For = 60 toward the cold wall (case 20), the reduction in heat transfer is 30.2%.
d. For = 30 toward the hot wall (case 21), the reduction in heat transfer is 31.3%.
e. For = 45 toward the hot wall (case 17), the reduction in heat transfer is 40.7%.

f. For = 60 toward the hot wall (case 19), the reduction in heat transfer is 42.1%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Oct 01 2024
Journal Name
Journal Of Physics: Conference Series
A comparative Analytical Investigation of Different Geomagnetic Storms During Solar Cycles 23 and 24
...Show More Authors
Abstract<p>In this work, the geomagnetic storms that occurred during solar cycles 23 and 24 were classified based on the value of the Disturbance Storm Time index (Dst), which was considered an indicator of the strength of geomagnetic conditions. The special criterion of Dst >-50 nT was adopted in the classification process of the geomagnetic storms based on the minimum daily value of the Dst-index. The number of geomagnetic storms that occurred during the study period was counted according to the adopted criteria, including moderate storms with (Dst >-50 nT), strong storms with (Dst >-100 nT), severe storms with (Dst >-200 nT), and great storms with (Dst >-350 nT). The statistica</p> ... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu May 02 2013
Journal Name
Journal Of Engineering
Experimental and numerical analysis of piled raft foundation with different length of piles under static loads
...Show More Authors

In order to understand the effect of (length of pile / diameter of pile) ratio on the load carrying capacity and settlement reduction behavior of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The parameters studied were the effect of pile length and the number of piles. The load settlement behavior obtained from the tests has been validated by using 3-D finite element in ABAQUS program, was adopted to understand the load carrying response of piled raft and settlement reduction. The results of experimental work show that the increase in (Lp/dp) ratio led to increase in load carrying capacity by piled raft from (19.75 to 29.35%), (14.18 to 28.87%) and (0 to 16.49%) , the maximum load carr

... Show More
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental and Numerical Analysis of Piled Raft Foundation with Different Length of Piles Under Static Loads
...Show More Authors

In order to understand the effect of (length of pile / diameter of pile) ratio on the load carrying capacity and settlement reduction behavior of piled raft resting on loose sand, laboratory model tests were conducted on small-scale models. The parameters studied were the effect of pile length and the number of piles. The load settlement behavior obtained from the tests has been validated by using 3-D finite element in ABAQUS program, was adopted to understand the load carrying response of piled raft and settlement reduction. The results of experimental work show that the increase in (Lp/dp) ratio led to increase in load carrying capacity by piled raft from (19.75 to 29.35%), (14.18 to 28.87%) and (0 to 16.49%) , the maximum load carried

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon May 04 2020
Journal Name
Environmental Engineering Research
Experimental and modeling study of water defluoridation using waste granular brick in a continuous up-flow fixed bed
...Show More Authors

Contamination of surface and groundwater with excessive concentrations of fluoride is of significant health hazard. Adsorption of fluoride onto waste materials of no economic value could be a potential approach for the treatment of fluoride-bearing water. This experimental and modeling study was devoted to investigate for the first the fluoride removal using unmodified waste granular brick (WGB) in a fixed bed running in continuous mode. Characterization of WGB was carried out by FT-IR, SEM, and EDX analysis. The batch mode experiments showed that they were affected by several parameters including contact time, initial pH, and sorbent dosage. The best values of these parameters that provided maximum removal percent (82%) with the in

... Show More
Scopus (19)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Journal Of Current Researches On Social Sciences
An Examination of Discourse Investigation of Fallacies in Religious Texts: Islam as a Case Study
...Show More Authors

BN RASHİD, 2023

View Publication
Publication Date
Tue Aug 01 2023
Journal Name
Baghdad Science Journal
Performance Evaluation of a Triple Concentric Tube Heat Exchanger Using Deionized Water and Oil-40
...Show More Authors

This study examines experimentally the performance of a horizontal triple concentric tube heat exchanger TCTHE made of copper metal using water as cooling fluid and oil-40 as hot fluid. Hot fluid enters the inner annular tube of the TCTHE in a direction at a temperature of 50, 60 and 70 oC and a flow rate of 20 l/hr. On the other hand, the cooling fluid enters the inner tube and the outer annular tube in the reverse direction (counter current flow) at a temperature of 25 oC and flow rates of 10, 15, 20, 25, 30 and 35 l/hr. The TCTHE is composed of three copper tubes with outer diameters of 34.925 mm, 22.25 mm, and 9.525 mm, and thicknesses of 1.27 mm, 1.143 mm, and 0.762 mm, respectively. TCTHE tube's length was 670

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Nov 28 2018
Journal Name
Al-khwarizmi Engineering Journal
Effect of Using Combined Square Nozzle & winglet with Helical Tape on Thermal Characteristics in Tube Heat Exchanger
...Show More Authors

Influence of combined square nozzle with helical tape inserted in a constant heat flux tube on heat transfer enhancement for turbulent airflow for Reynolds number ranging from 7000 to 14500 were investigated experimentally. Three different pitch ratios for square nozzle (PR = 5.8, 7.7 and 11.6) according to three different numbers of square nozzle (N = 3, 4 and 5) and constant pitch ratios for helical tape were used. The results observed that the Nusselt number and friction factor for combination with winglets were found to be up to 33.8 % and 21.4 %, respectively higher than nozzle alone for pitch ratio PR=5.8. The maximum value of thermal performance for using combination with winglets was about 1.351 for pitch ratio= 5.8. Nusselt numb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heat

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2011
Journal Name
Journal Of Engineering
EXPERIMENTAL OBSERVATIONS ON THE BEHAVIOR OF A PILED RAFT FOUNDATION
...Show More Authors

The piled raft is a geotechnical composite construction consisting of three elements: piles, raft and soil.
In the design of piled rafts, the load shared between the piles and the raft, and the piles are used up to a
load level that can be of the same order of magnitude as the bearing capacity of a comparable single
pile or even greater. Therefore, the piled raft foundation allows reduction of settlements in a very
economic way as compared to traditional foundation concepts.
This paper presents experimental study to investigate the behavior of piled raft system in sandy
soil. A small scale “prototype” model was tested in a sand box with load applied to the system through
a compression machine. The settlement was

... Show More
View Publication Preview PDF
Crossref (11)
Crossref
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Clonazepam in Pure and Dosage forms using Charge Transfer Reaction
...Show More Authors

A rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea

... Show More
View Publication Preview PDF
Crossref (7)
Crossref