Preferred Language
Articles
/
joe-2986
EXPERIMENTAL INVESTIGATION OF LAMINAR NATURAL CONVECTION HEAT TRANSFER IN A RECTANGULAR ENCLOSURE WITH AND WITHOUT INSIDE PARTITIONS
...Show More Authors

Experimental study has been conducted for laminar natural convection heat transfer of air flow through a rectangular enclosure fitted with vertical partition. The partition was oriented parallel to the two vertical isothermal walls with different temperatures, while all the other surfaces of the enclosure were insulated. In this study a test rig has been designed and constructed to allow studying the effect of Rayleigh number, aperture height ratio, partition thickness, the position of aperture according to the side walls and according to the height, the position of the partition according to the hot wall, and partition inclination. The experiments were carried out with air as the working fluid for Rayleigh number range (5*107 – 1.3*108) and aspect ratio of (0.5). 22 different configurations of partition were used in this study these are:
a) Undivided enclosure (no – partition).
b) (21) Cork partitions of different shapes.
Empirical correlations for average Nusselt number are obtained for the different cases tested. The results show that heat transfer is independent on the partition position according to the cold wall and according to the upper or lower walls, while it shows that heat transfer is sensitive to:
1. Rayleigh number (Ra), which increase with increasing Ra.
2. Aperture height ratio (Ap=hp/H), which is found that when Ap= 5/6 (case 2,3), the reduction in heat transfer is 10.3%, while when Ap=1/2 (case 4,5), the reduction is 17.2% compared with the non partitioned enclosure.
3. Aperture position according to the height, which is found that when the aperture at the centre of the partition (case 13), the reduction in heat transfer is 16.7%, while when the aperture displaced to the upper surface (case 14), the reduction is 19% compared with the non partitioned enclosure.
4. Partition thickness (t), which is found that when t = 10 mm (case 4,5) the reduction in heat transfer is 17.2%, while when t = 150 mm (case 16) the reduction is 20.5% compared with the non partitioned enclosure.
5. Partition inclination (), which is found that the rate of heat transfer reduced with increasingas shown:
a. For = 30 toward the cold wall (case 22), the reduction in heat transfer is 18.2%.
b. For = 45 toward the cold wall (case 18), the reduction in heat transfer was 21.9%.
c. For = 60 toward the cold wall (case 20), the reduction in heat transfer is 30.2%.
d. For = 30 toward the hot wall (case 21), the reduction in heat transfer is 31.3%.
e. For = 45 toward the hot wall (case 17), the reduction in heat transfer is 40.7%.

f. For = 60 toward the hot wall (case 19), the reduction in heat transfer is 42.1%.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Dec 30 2018
Journal Name
2018 Computing In Cardiology Conference (cinc)
Theoretical and Experimental Reflection Coefficients in Flexible Tubes as a Function of the Mach Number
...Show More Authors

The standard formulation of Wave Intensity Analysis (WIA) assumes that the flow velocity (U) in the conduit is <;<; the velocity of propagation of waves (c) in the system, and Mach number, M=U/c, is negligible. However, in the large conduit arteries, U is relatively high due to ventricular contraction and c is relatively low due to the large compliance; thus M is > 0, and may not be ignored. Therefore, the aim of this study is to identify experimentally the relationship between M and the reflection coefficient in vitro. Combinations of flexible tubes, of 2 m in length with isotropic and uniform circular cross sectional area along their longitudinal axes, were used to present mother and daughter tubes to produce a range of reflection coeffic

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
Investigation of the association of AGTR1 A1166C rs5186 and FTO rs9939609 polymorphisms with the obesity in children and adolescents
...Show More Authors

Obesity is a risk factor for a number of chronic conditions. Obesity is clinically defined using the body mass index (BMI) as weight in kg divided by (height)2 in m2 correlated with obesity. Currently, genetic markers of obesity are being studied. This study focused on the association between the angiotensin II receptor AGTR1 gene (A1166C) and fat mass and obesity-associated protein also known as alpha-ketoglutarate-dependent dioxygenase (FTO) (rs9939609) in obese children and adolescents patients in Rostov region, Russia.  Five-hundreds of Russian nationality child and adolescent were recruited for the obesity-control studies. The relationship between the A1166C polymorphism of the AGTR1 gene in

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Building Engineering
Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
...Show More Authors

This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol

... Show More
View Publication
Scopus (60)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Building Engineering
Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
...Show More Authors

This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol

... Show More
View Publication
Scopus (60)
Crossref (19)
Scopus Crossref
Publication Date
Mon Jul 27 2026
Journal Name
Aip Conference Proceedings
Investigation of angiotensin role and its converting enzyme for Iraqi patients with asthma
...Show More Authors

Asthma is a chronic disease characterized by inflammatory events in the airways, that makes breathing a hard process in these patients. Angiotensin II (AngII) is important regulator for aldosterone production. Also, it participates in inducing reactive oxygen species (ROS) and inflammatory events. Angiotensin-converting enzyme (ACE) is responsible for the production of AngII. We hypothesised that ACE and AngII participate in the progression of asthma by increasing ROS production and inflammatory processes. Thus, we evaluated the level of AngII, the activity of ACE, and the level of malondialdehyde (MDA) as indicators for oxidative stress in 60 asthmatic male patients and 30 non-asthmatic male control. An asthma control test (ACT) was estima

... Show More
View Publication
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Investigating the quality of open street map roads data inside Baghdad city
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Sep 21 2016
Journal Name
Applicable Analysis
Retrieving the time-dependent thermal conductivity of an orthotropic rectangular conductor
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
An Experimental Study of Capillary Tubes Behavior With R-12 and R-134a
...Show More Authors

 

Experimental work has been performed on three capillary tubes of different lengths and diameters using R-12 and R-134a. The test also studies the effect of discharge and speed of evaporator fan. The results clearly showed that refrigerant type and discharge significantly influence the temperature drop across the capillary tube. While the speed of evaporator fan has small effect. Experimental results showed that the temperature gradient for the two refrigerants are the same, but after approximatly one meter the temperature gradient of R-134a  is steeper than R-12.

 

View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Energy Conversion And Management
Simultaneous energy storage and recovery in the triplex-tube heat exchanger with PCM, copper fins and Al2O3 nanoparticles
...Show More Authors

View Publication
Scopus (280)
Crossref (276)
Scopus Clarivate Crossref
Publication Date
Mon Oct 12 2020
Journal Name
Molecules
Phase Change Process in a Zigzag Plate Latent Heat Storage System during Melting and Solidification
...Show More Authors

Applying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melti

... Show More
View Publication
Scopus (50)
Crossref (49)
Scopus Clarivate Crossref